Avaliação do teste bovigam TM na dosagem de interferon gama para diagnóstico da tuberculose bovina

=== This study demonstrates the correlation between the test of interferon gamma (INF ) and tuberculin intradermal tests in the diagnosis of bovine tuberculosis in Brazilian conditions. Centre and two animals from four dairy herds in the state of Minas Gerais tuberculinazados way and the results we...

Full description

Bibliographic Details
Main Author: Luciano Bastos Lopes
Other Authors: Romulo Cerqueira Leite
Format: Others
Language:Portuguese
Published: Universidade Federal de Minas Gerais 2003
Online Access:http://hdl.handle.net/1843/BUOS-8C4HE4
id ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8C4HE4
record_format oai_dc
spelling ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8C4HE42019-01-21T17:55:02Z Avaliação do teste bovigam TM na dosagem de interferon gama para diagnóstico da tuberculose bovina Luciano Bastos Lopes Romulo Cerqueira Leite Andrey Pereira Lage Francisco Carlos Faria Lobato José Soares Ferreira Neto Henrique Cesar Pereira Figueiredo This study demonstrates the correlation between the test of interferon gamma (INF ) and tuberculin intradermal tests in the diagnosis of bovine tuberculosis in Brazilian conditions. Centre and two animals from four dairy herds in the state of Minas Gerais tuberculinazados way and the results were then compared with the gamma interferon test. For detection of INF , we used a commercial ELISA kit, BOVIGAM . The results showed no significant differences between the frequencies of animals according to positive and negative intradermal tuberculin test compared intercom and testing range on day zero and within 72 hours after inoculation of tuberculin. The agreement between the test ranged from 79.4% to 85.3% according to the Kappa test. There were no significant differences between mean values of optical densities between the two collection days. Este trabalho demonstra a concordância existente entre o teste do interferon gama (INF ) e a tuberculinização intradérmica comparada no diagnostico da tuberculose bovina em condições brasileiras. Centro e dois animais provenientes de quatro rebanhos leiteiros no estado de Minas Gerais forma tuberculinazados e os resultados obtidos foram então comparados com o teste de interferon gama. Para detecção do INF utilizou-se um kit comercial de ELISA, BOVIGAM. Os resultados demonstraram não haver diferenças significativas entre as freqüências de animais positivos e negativos segundo os teste de tuberculinização intradérmica comparada e o teste de interfon gama no dia zero e após decorridas 72 horas da inoculação de tuberculina. A concordância entre os teste variou de 79,4% a 85,3% segundo o teste de Kappa. Não foram encontradas diferenças significativas entre os valores médios das densidades óticas entre os dois dias de coleta 2003-02-28 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://hdl.handle.net/1843/BUOS-8C4HE4 por info:eu-repo/semantics/openAccess text/html Universidade Federal de Minas Gerais 32001010030P7 - MEDICINA VETERINÁRIA UFMG BR reponame:Biblioteca Digital de Teses e Dissertações da UFMG instname:Universidade Federal de Minas Gerais instacron:UFMG
collection NDLTD
language Portuguese
format Others
sources NDLTD
description === This study demonstrates the correlation between the test of interferon gamma (INF ) and tuberculin intradermal tests in the diagnosis of bovine tuberculosis in Brazilian conditions. Centre and two animals from four dairy herds in the state of Minas Gerais tuberculinazados way and the results were then compared with the gamma interferon test. For detection of INF , we used a commercial ELISA kit, BOVIGAM . The results showed no significant differences between the frequencies of animals according to positive and negative intradermal tuberculin test compared intercom and testing range on day zero and within 72 hours after inoculation of tuberculin. The agreement between the test ranged from 79.4% to 85.3% according to the Kappa test. There were no significant differences between mean values of optical densities between the two collection days. === Este trabalho demonstra a concordância existente entre o teste do interferon gama (INF ) e a tuberculinização intradérmica comparada no diagnostico da tuberculose bovina em condições brasileiras. Centro e dois animais provenientes de quatro rebanhos leiteiros no estado de Minas Gerais forma tuberculinazados e os resultados obtidos foram então comparados com o teste de interferon gama. Para detecção do INF utilizou-se um kit comercial de ELISA, BOVIGAM. Os resultados demonstraram não haver diferenças significativas entre as freqüências de animais positivos e negativos segundo os teste de tuberculinização intradérmica comparada e o teste de interfon gama no dia zero e após decorridas 72 horas da inoculação de tuberculina. A concordância entre os teste variou de 79,4% a 85,3% segundo o teste de Kappa. Não foram encontradas diferenças significativas entre os valores médios das densidades óticas entre os dois dias de coleta
author2 Romulo Cerqueira Leite
author_facet Romulo Cerqueira Leite
Luciano Bastos Lopes
author Luciano Bastos Lopes
spellingShingle Luciano Bastos Lopes
Avaliação do teste bovigam TM na dosagem de interferon gama para diagnóstico da tuberculose bovina
author_sort Luciano Bastos Lopes
title Avaliação do teste bovigam TM na dosagem de interferon gama para diagnóstico da tuberculose bovina
title_short Avaliação do teste bovigam TM na dosagem de interferon gama para diagnóstico da tuberculose bovina
title_full Avaliação do teste bovigam TM na dosagem de interferon gama para diagnóstico da tuberculose bovina
title_fullStr Avaliação do teste bovigam TM na dosagem de interferon gama para diagnóstico da tuberculose bovina
title_full_unstemmed Avaliação do teste bovigam TM na dosagem de interferon gama para diagnóstico da tuberculose bovina
title_sort avaliação do teste bovigam tm na dosagem de interferon gama para diagnóstico da tuberculose bovina
publisher Universidade Federal de Minas Gerais
publishDate 2003
url http://hdl.handle.net/1843/BUOS-8C4HE4
work_keys_str_mv AT lucianobastoslopes avaliacaodotestebovigamtmnadosagemdeinterferongamaparadiagnosticodatuberculosebovina
_version_ 1718844093585424384