As medidas cranianas no diagnóstico das craniossinostoses

=== Craniosynostosis are a group of growth disturbances of the skull, which can result in serious consequences for the child. Early diagnosis provides treatment at the correct time. The head circumference (HC) is usually used as a parameter for its diagnosis, but the HC does not appear to be change...

Full description

Bibliographic Details
Main Author: José Aloysio da Costa Val Filho
Other Authors: Sebastiao Nataniel Silva Gusmao
Format: Others
Language:Portuguese
Published: Universidade Federal de Minas Gerais 2013
Online Access:http://hdl.handle.net/1843/BUBD-A2DFW5
id ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUBD-A2DFW5
record_format oai_dc
spelling ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUBD-A2DFW52019-01-21T18:09:28Z As medidas cranianas no diagnóstico das craniossinostoses José Aloysio da Costa Val Filho Sebastiao Nataniel Silva Gusmao Aluizio Augusto Arantes Junior Cassius Vinicius Correa dos Reis Craniosynostosis are a group of growth disturbances of the skull, which can result in serious consequences for the child. Early diagnosis provides treatment at the correct time. The head circumference (HC) is usually used as a parameter for its diagnosis, but the HC does not appear to be changed in this disease, leading to incorrect interpretations. The Anteroposterior Distance (APD) and Biauricular Distance (BAD) appear to be more accurate. The aims of this study are to analyze the value of the HC and the ratio of the measures APD to BAD for this diagnosis. We analyzed the data from 129 children who had already undergone an operation for craniosynostosis at the Biocor Instituto, from 2008 to 2010. These data were compared with the normal standards of the population and statistically analyzed to establish their alterations. The HC did not change significantly in craniosynostosis, either as a single group or when considering the subtypes. The APD/BAD ratio changed significantly in the group. The HC does not appear to be useful in the diagnosis of craniosynostosis as an individual parameter. The ratio of the measures APD to BAD appears to help in the diagnosis, as does the relationship of this ratio with the HC. As craniossinostoses são um grupo de alterações do crescimento e formato do crânio que podem resultar em graves consequências para a criança. Seu diagnóstico precoce propicia o tratamento a tempo correto. O perímetro cefálico (PC) é habitualmente usado como parâmetro para o diagnóstico. Porém, como na maioria das vezes há alteração na forma e não na medida do perímetro, a utilização desta medida isoladamente pode levar a atraso no diagnóstico da doença. As medidas do diâmetro anteroposterior (DAP) e diâmetro biauricular (DBA ) parecem ser mais precisas no auxílio do diagnóstico. O objetivo deste trabalho é analisar o papel do PC neste diagnóstico, bem como o da razão entre as medidas DAP/ DBA, além de uma possível relação entre o PC e a razão DAP/DBA. Foram analisadas os dados de 129 crianças operadas por craniossinostose no Biocor Instituto, Nova Lima, entre 2008 e 2010. Estes dados foram comparados com os padrões de normalidade da população e analisados estatisticamente, como um grupo único e nos diversos subtipos, a fim de se estabelecer seus valores nas crianças portadoras da doença. O resultado da análise mostrou que o PC não se alterou de maneira significativa nas craniossinostoses, seja como grupo único ou nos subtipos da doença. A razão das medidas DAP/ DBA alterou-se estatisticamente no amostra estudada. Conclui-se que o PC não parece ser útil no diagnóstico das craniossinostoses como parâmetro isolado. A razão das medidas DAP/ DBA parece auxiliar no diagnóstico. 2013-11-25 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://hdl.handle.net/1843/BUBD-A2DFW5 por info:eu-repo/semantics/openAccess text/html Universidade Federal de Minas Gerais 32001010069P0 - CIRURGIA UFMG BR reponame:Biblioteca Digital de Teses e Dissertações da UFMG instname:Universidade Federal de Minas Gerais instacron:UFMG
collection NDLTD
language Portuguese
format Others
sources NDLTD
description === Craniosynostosis are a group of growth disturbances of the skull, which can result in serious consequences for the child. Early diagnosis provides treatment at the correct time. The head circumference (HC) is usually used as a parameter for its diagnosis, but the HC does not appear to be changed in this disease, leading to incorrect interpretations. The Anteroposterior Distance (APD) and Biauricular Distance (BAD) appear to be more accurate. The aims of this study are to analyze the value of the HC and the ratio of the measures APD to BAD for this diagnosis. We analyzed the data from 129 children who had already undergone an operation for craniosynostosis at the Biocor Instituto, from 2008 to 2010. These data were compared with the normal standards of the population and statistically analyzed to establish their alterations. The HC did not change significantly in craniosynostosis, either as a single group or when considering the subtypes. The APD/BAD ratio changed significantly in the group. The HC does not appear to be useful in the diagnosis of craniosynostosis as an individual parameter. The ratio of the measures APD to BAD appears to help in the diagnosis, as does the relationship of this ratio with the HC. === As craniossinostoses são um grupo de alterações do crescimento e formato do crânio que podem resultar em graves consequências para a criança. Seu diagnóstico precoce propicia o tratamento a tempo correto. O perímetro cefálico (PC) é habitualmente usado como parâmetro para o diagnóstico. Porém, como na maioria das vezes há alteração na forma e não na medida do perímetro, a utilização desta medida isoladamente pode levar a atraso no diagnóstico da doença. As medidas do diâmetro anteroposterior (DAP) e diâmetro biauricular (DBA ) parecem ser mais precisas no auxílio do diagnóstico. O objetivo deste trabalho é analisar o papel do PC neste diagnóstico, bem como o da razão entre as medidas DAP/ DBA, além de uma possível relação entre o PC e a razão DAP/DBA. Foram analisadas os dados de 129 crianças operadas por craniossinostose no Biocor Instituto, Nova Lima, entre 2008 e 2010. Estes dados foram comparados com os padrões de normalidade da população e analisados estatisticamente, como um grupo único e nos diversos subtipos, a fim de se estabelecer seus valores nas crianças portadoras da doença. O resultado da análise mostrou que o PC não se alterou de maneira significativa nas craniossinostoses, seja como grupo único ou nos subtipos da doença. A razão das medidas DAP/ DBA alterou-se estatisticamente no amostra estudada. Conclui-se que o PC não parece ser útil no diagnóstico das craniossinostoses como parâmetro isolado. A razão das medidas DAP/ DBA parece auxiliar no diagnóstico.
author2 Sebastiao Nataniel Silva Gusmao
author_facet Sebastiao Nataniel Silva Gusmao
José Aloysio da Costa Val Filho
author José Aloysio da Costa Val Filho
spellingShingle José Aloysio da Costa Val Filho
As medidas cranianas no diagnóstico das craniossinostoses
author_sort José Aloysio da Costa Val Filho
title As medidas cranianas no diagnóstico das craniossinostoses
title_short As medidas cranianas no diagnóstico das craniossinostoses
title_full As medidas cranianas no diagnóstico das craniossinostoses
title_fullStr As medidas cranianas no diagnóstico das craniossinostoses
title_full_unstemmed As medidas cranianas no diagnóstico das craniossinostoses
title_sort as medidas cranianas no diagnóstico das craniossinostoses
publisher Universidade Federal de Minas Gerais
publishDate 2013
url http://hdl.handle.net/1843/BUBD-A2DFW5
work_keys_str_mv AT josealoysiodacostavalfilho asmedidascranianasnodiagnosticodascraniossinostoses
_version_ 1718847696623632384