Estudo fluidodinâmico computacional da transferência de calor de uma conexão elétrica tipo H

=== All energy that is generated, transmitted and distributed requires electricity to pass by electrical connections at various points. The ever-increasing demands for electricity and the shortage of new economically viable generation sources, presenting projects distant from consumers connected by...

Full description

Bibliographic Details
Main Author: Gilberto Antunes Renno Junior
Other Authors: Rudolf Huebner
Format: Others
Language:Portuguese
Published: Universidade Federal de Minas Gerais 2013
Online Access:http://hdl.handle.net/1843/BUBD-9BVK4V
id ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUBD-9BVK4V
record_format oai_dc
spelling ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUBD-9BVK4V2019-01-21T18:06:03Z Estudo fluidodinâmico computacional da transferência de calor de uma conexão elétrica tipo H Gilberto Antunes Renno Junior Rudolf Huebner Roberto Marcio de Andrade Marcio Fonte Boa Cortez All energy that is generated, transmitted and distributed requires electricity to pass by electrical connections at various points. The ever-increasing demands for electricity and the shortage of new economically viable generation sources, presenting projects distant from consumers connected by long power transmission lines makes the study of power connections important. The operations, product quality, and equipment reliability, availability, and maintainability are now pushed to unprecedented levels while staying within budgetary constraints. One of the most visible ways of perceiving the state of degradation of a power connection is it high temperature. This dissertation presents the study of an "H" type compression power connection heat transfer, commonly used in power distribution systems, in order to study the heat transfer in quiescent state and in the presence of crossow. A computational uids dynamics (CFD) numerical simulation is performed and validated by comparing with obtained experimental data. Then it is studied the streamlines, the pressure variation and the local and average convection heat transfer coecient, in steady and unsteady state. Finally, local and average Nusselt number correlations for this connection are described. The temperature results obtained by numerical simulation were close to those obtained experimentally, with the maximum deviation of 6%. The mean convection heat transfer coecient met similar values when compared with the classical correlations for a cylinder of equivalent diameter, and the maximum difference found is 19%. Toda energia que é gerada, transmitida e distribuída exige que a eletricidade passe por conexões elétricas em diversos pontos. A grande e crescente demanda por energia elétrica e a escassez de novas fontes economicamente viáveis, com empreendimentos de geração cada vez mais distantes dos centros consumidores conectados por extensas linhas de transmissão tornam o estudo de conexões elétricas importante. A operação, qualidade do produto, conabilidade dos equipamentos, disponibilidade e facilidade manutenção são agora pressionadas para níveis sem precedentes, sujeitas a restrições orçamentárias cada vez maiores. Uma das maneiras mais visíveis de perceber o estado de degradação de uma conexão elétrica é sua elevada temperatura. Esta dissertação apresenta o estudo da troca de calor por convecção de uma conexão elétrica tipo H, comumente utilizada em redes de distribuição de energia elétrica, com o intuito de estudar os fenômenos da transferência de calor para convecção natural e forçada. Para isto é realizada uma simulação numérica utilizando fluidodinâmica computacional (CFD) validada pela comparação com dados obtidos experimentalmente. A partir desta estudam-se o comportamento das linhas de corrente, a variação da pressão e os valores do coeciente de troca de calor por convecção local e médio, em regime permanente e transiente. Finalmente, são descritas correlações para a determinação do número de Nusselt médio e local desta conexão. Os resultados de temperatura obtidos pela a simulação numérica foram próximos aos obtidos experimentalmente, sendo o desvio máximo de 6%. Para o coeciente médio de transferência de calor por convecção, encontrou-se valores semelhantes ao se comparar com as correlações clássicas para um cilindro de diâmetro equivalente, sendo a diferença máxima de 19%. 2013-08-01 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://hdl.handle.net/1843/BUBD-9BVK4V por info:eu-repo/semantics/openAccess text/html Universidade Federal de Minas Gerais 32001010016P4 - ENGENHARIA MECANICA UFMG BR reponame:Biblioteca Digital de Teses e Dissertações da UFMG instname:Universidade Federal de Minas Gerais instacron:UFMG
collection NDLTD
language Portuguese
format Others
sources NDLTD
description === All energy that is generated, transmitted and distributed requires electricity to pass by electrical connections at various points. The ever-increasing demands for electricity and the shortage of new economically viable generation sources, presenting projects distant from consumers connected by long power transmission lines makes the study of power connections important. The operations, product quality, and equipment reliability, availability, and maintainability are now pushed to unprecedented levels while staying within budgetary constraints. One of the most visible ways of perceiving the state of degradation of a power connection is it high temperature. This dissertation presents the study of an "H" type compression power connection heat transfer, commonly used in power distribution systems, in order to study the heat transfer in quiescent state and in the presence of crossow. A computational uids dynamics (CFD) numerical simulation is performed and validated by comparing with obtained experimental data. Then it is studied the streamlines, the pressure variation and the local and average convection heat transfer coecient, in steady and unsteady state. Finally, local and average Nusselt number correlations for this connection are described. The temperature results obtained by numerical simulation were close to those obtained experimentally, with the maximum deviation of 6%. The mean convection heat transfer coecient met similar values when compared with the classical correlations for a cylinder of equivalent diameter, and the maximum difference found is 19%. === Toda energia que é gerada, transmitida e distribuída exige que a eletricidade passe por conexões elétricas em diversos pontos. A grande e crescente demanda por energia elétrica e a escassez de novas fontes economicamente viáveis, com empreendimentos de geração cada vez mais distantes dos centros consumidores conectados por extensas linhas de transmissão tornam o estudo de conexões elétricas importante. A operação, qualidade do produto, conabilidade dos equipamentos, disponibilidade e facilidade manutenção são agora pressionadas para níveis sem precedentes, sujeitas a restrições orçamentárias cada vez maiores. Uma das maneiras mais visíveis de perceber o estado de degradação de uma conexão elétrica é sua elevada temperatura. Esta dissertação apresenta o estudo da troca de calor por convecção de uma conexão elétrica tipo H, comumente utilizada em redes de distribuição de energia elétrica, com o intuito de estudar os fenômenos da transferência de calor para convecção natural e forçada. Para isto é realizada uma simulação numérica utilizando fluidodinâmica computacional (CFD) validada pela comparação com dados obtidos experimentalmente. A partir desta estudam-se o comportamento das linhas de corrente, a variação da pressão e os valores do coeciente de troca de calor por convecção local e médio, em regime permanente e transiente. Finalmente, são descritas correlações para a determinação do número de Nusselt médio e local desta conexão. Os resultados de temperatura obtidos pela a simulação numérica foram próximos aos obtidos experimentalmente, sendo o desvio máximo de 6%. Para o coeciente médio de transferência de calor por convecção, encontrou-se valores semelhantes ao se comparar com as correlações clássicas para um cilindro de diâmetro equivalente, sendo a diferença máxima de 19%.
author2 Rudolf Huebner
author_facet Rudolf Huebner
Gilberto Antunes Renno Junior
author Gilberto Antunes Renno Junior
spellingShingle Gilberto Antunes Renno Junior
Estudo fluidodinâmico computacional da transferência de calor de uma conexão elétrica tipo H
author_sort Gilberto Antunes Renno Junior
title Estudo fluidodinâmico computacional da transferência de calor de uma conexão elétrica tipo H
title_short Estudo fluidodinâmico computacional da transferência de calor de uma conexão elétrica tipo H
title_full Estudo fluidodinâmico computacional da transferência de calor de uma conexão elétrica tipo H
title_fullStr Estudo fluidodinâmico computacional da transferência de calor de uma conexão elétrica tipo H
title_full_unstemmed Estudo fluidodinâmico computacional da transferência de calor de uma conexão elétrica tipo H
title_sort estudo fluidodinâmico computacional da transferência de calor de uma conexão elétrica tipo h
publisher Universidade Federal de Minas Gerais
publishDate 2013
url http://hdl.handle.net/1843/BUBD-9BVK4V
work_keys_str_mv AT gilbertoantunesrennojunior estudofluidodinamicocomputacionaldatransferenciadecalordeumaconexaoeletricatipoh
_version_ 1718846761109291008