DEVELOPMENT OF CAPILLARY ELECTROPHORESIS BASED METHODS WITH DIFFERENT DETECTION APPROACHES FOR DETERMINATION OF ORGANOTINS, STROBILURINS AND AMINOGLYCOSIDES

PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO === COORDENAÇÃO DE APERFEIÇOAMENTO DO PESSOAL DE ENSINO SUPERIOR === CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO === PROGRAMA DE EXCELENCIA ACADEMICA === Neste trabalho, métodos baseados em diferentes abordagens em eletroforese cap...

Full description

Bibliographic Details
Main Author: CABRINI FERRAZ DE SOUZA
Other Authors: RICARDO QUEIROZ AUCELIO
Language:Portuguese
Published: PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO 2013
Online Access:http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=23181@1
http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=23181@2
id ndltd-IBICT-oai-MAXWELL.puc-rio.br-23181
record_format oai_dc
collection NDLTD
language Portuguese
sources NDLTD
description PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO === COORDENAÇÃO DE APERFEIÇOAMENTO DO PESSOAL DE ENSINO SUPERIOR === CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO === PROGRAMA DE EXCELENCIA ACADEMICA === Neste trabalho, métodos baseados em diferentes abordagens em eletroforese capilar (CE) foram propostos. No caso da determinação de compostos organoestanhos ou OTs (difenilestanho e monofenilestanho) em fluidos biológicos, foi usada abordagem de eletroforese capilar por zona (CZE) hifenada com a espectrometria de massas (do tipo quadrupolo) com fonte de plasma indutivamente acoplado (CE-ICP-MS). As condições de análise foram estudadas no modo univariado visando otimizar a composição da solução eletrolítica (tampão acetato 5,0 mmol L(-1), pH 2,8) e obter os parâmetros instrumentais (45 graus Celsius, mais 30 kV e 30 s de tempo de introdução hidrodinâmica de amostra). A solução de complementação foi uma solução aquosa 5,0 mmol L(-1) de NH4NO3 contendo 10 por cento metanol em volume e 1,0 Mg L(-1) de Cspositivo, com pH ajustado para 2,8 com tampão acetato. A vazão dessa solução foi mantida em 40 ML min(-1). Os OTs foram diluídos em solução de metanol:tampão acetato de sódio 50:50 por cento v/v ou apenas em tampão acetato de sódio pH 2,8. As condições de detecção do ICP-MS foram ajustadas em 1200 W, 15 L min(-1) de vazão de argônio para formação do plasma, 1 L min(-1) de vazão de argônio auxiliar. A vazão de argônio do nebulizador foi ajustada diariamente. Os isótopos de estanho 120Sn e 118Sn foram monitorados, assim como o 133Cspositivo para controlar a eficiência e estabilidade do processo de nebulização. A resposta linear do método ficou entre 0,050 a 2,0 mg L(-1) de Sn (0,42 a 17 Mmol L-(1)). Os limites de detecção (LOD) e de quantificação (LOQ) em termos de Sn foram de 15 Mg L(-1) (0,13 Mmol L(-1)) e 50 Mg L-1 (0,42 Mmol L(-1)), calculados utilizando a menor concentração dos picos dos analitos que podem ser diferenciados do sinal de fundo. A repetibilidade para o tempo de migração e área dos picos ficou próximo a 5 por cento. O método foi aplicado na análise de urina, sangue total e plasma fortificados com os OTs. Recuperações entre 75 e 95 por cento foram obtidas. No caso da determinação de sete pesticidas da classe das estrobilurinas (azoxistrobina, 9 dimoxistrobina, fluoxastrobina, picoxistrobina, piraclostrobina, trifloxistrobina e kresoxim-metil) em sopas infantis, foi usada a cromatografia eletrocinética capilar micelar (MEKC) com detecção fotométrica (no UV) com capilar de caminho óptico estendido. Um estudo multivariado, usando um planejamento 33 Box Behnken, indicou que a melhor separação para os pesticidas foi com solução aquosa de eletrólito composto por tampão tetraborato de sódio (5,1 mmol L(-1), pH 9,0) contendo 51 mmol L(-1) de dodecil sulfato de sódio (SDS) e 24 por cento acetonitrila (ACN) em volume. As condições instrumentais foram 25 C e mais 30 kV de diferença de potencial aplicada, 45 s de tempo de introdução hidrodinâmica de amostra e detecção em 210 nm. Para aumentar o poder de detecção, foi usada a concentração dos analitos no capilar. Para tal, as soluções de padrões e amostras foram dissolvidas em solução tampão tetraborato de sódio 45 mmol L(-1): acetonitrila 80:20 por cento v/v. As curvas analíticas apresentaram comportamento linear e os valores de LOD ficaram entre 7,0 Mg L(-1) ou 18 nmol L(-1) (piraclostrobina) a 15 Mg L-1 ou 33 nmol L(-1) (fluoxastrobina). Os valores de LOQ ficaram entre 21 Mg L(-1) ou 54 nmol L(-1) (piraclostrobina) a 45 Mg L(-1) ou 98 nmol L(-1) (fluoxastrobina). A repetibilidade ficou entre 1,7 a 7,9 por cento para a área de pico e entre 0,25 a 0,71 por cento para o tempo de migração. A precisão intermediária, avaliada com análises realizadas em diferentes dias, apresentou valores entre 1,3 a 5,3 por cento para a área de pico e entre 0,06 a 0,90 por cento para o tempo de migração. O método foi aplicado na análise de sopas prontas infantis fortificadas com as estrobilurinas. Os pesticidas foram extraídos aplicando o método QuEChERS com ajuste de pH com tampão acetato e limpeza com extração em fase sólida dispersiva. Os resultados das análises obtidos c === In this work, analytical methods based on different approaches using capillary electrophoresis (CE) have been proposed. For the determination of organotins or OTs (diphenyltin and monophenyltin) in biological fluids, the separation using capillary zone electrophoresis (CZE) was applied using tandem with inductively coupled plasma mass spectrometry (CE-ICP-MS). The conditions for the analysis were optimized in an unvaried way aiming to find the conditions for the electrolyte solution (acetate buffer, 5.0 mmol L (-1), pH 2.8) and the employed instrumental parameters (45C, 30 kV and 30 s of the time for hydrodynamic introduction of the sample). A complementary solution was composed by NH4NO3 5.0 mmol L(-1), 10 por cento v/v of methanol and 1.0 g L(-1) of Cspositive in acetate buffer with pH adjusted to 2.8. The flow of this solution was set to 40 ML min(-1). The OTs were diluted either in a methanol: acetate buffer 50:50 por cento v/v solution or only in sodium acetate buffer pH 2.8. The conditions for detection by ICP-MS were set to 1200 W, 15 L min(-1) for the Ar plasma flow and 1,0 L min(-1) for the auxiliary Ar. The nebulizer Ar flow was adjusted daily. The monitored tin isotopes were 120Sn 118Sn. The isotope 133Cs was also monitored in order to control the efficiency and stability of the nebulization. The method presented a linear response between 0.05 and 2.0 mg L(-1) (0.42 a 17 Mmol L(-1)) for Sn. The value for the limits of detection (LOD) and for the limits of quantification (LOQ) for Sn were 15 Mg L(-1) (0.13 Mmol L-1) e 50 Mg L(-1) (0.42 Mmol L(-1)), calculated based on the lowest concentration of the analyte peaks that can be differentiated from the background signal. The repeatability for migration time and peak area was approximately 5 per cent. The method was applied in the analysis of organotin fortified blood and urine samples with recoveries between 75 and 95 per cent. In the case of the determination of seven strobilurin class pesticides (azoxystrobin, dimoxystrobin, fluoxastrobin, picoxystrobin, pyraclostrobin, trifloxystrobin and kresoxim-methyl) in baby food (vegetable and fruit soups), 12 the micellar electrokinetic capillary chromatography (MEKC) was used using photometric detection (UV) in a capillary with extended optical path. A multivariate study, with 33 Box Behnken design, indicated the best composition for the electrolytic solution to separate the seven pesticides: a sodium tetraborate buffer (5.1 mmol L(-1), pH 9.0) solution containing 51 mmol L(-1) sodium dodecyl sulfate and acetonitrile (24 por cento in volume). The instrumental conditions were 25C, 30 kV of applied voltage, 45 s for hydrodynamic introduction of the sample and detection at 210 nm. To increase the detection power, the concentration of the analytes into the capillary was used by using the Normal Stacking Mode. For this purpose, the solutions of standards and samples were prepared in 45 mmol L(-1) sodium tetraborate buffer solution: acetonitrile 80:20 por cento v/v. The analytical curves presented a linear behavior and the LOD values were between 7.0 Mg L (-1) or 18 nmol L(-1) (pyraclostrobin) to 15 Mg L(-1) or 33 nmol L(-1) (fluoxastrobin). The LOQ values were between 21 Mg L(-1) or 54 nmol L(-1) (pyraclostrobin) a 45 Mg L(-1) ou 98 nmol L(-1) (fluoxastrobin). The repeatability was between 1.7 to 7.9 por cento for the peak area and between 0.25 to 0.71 por cento for the migration time. The intermediate precision, evaluated by the analysis performed in different days were between 1.3 to 5.3 por cento for the peak area and between 0.06 and 0.90 per cent for the migration time. The method was applied in the analysis of baby food spiked with strobilurin. Pesticides were extracted using the QuEChERS method with pH adjustment with acetate buffer and clean-up using the dispersive solid phase extraction. The analysis results were statistically identical to those obtained with a chromatographic method adapted from the literature. The CZE separation mode was chosen to evaluate the potential of the indirect determination of ami
author2 RICARDO QUEIROZ AUCELIO
author_facet RICARDO QUEIROZ AUCELIO
CABRINI FERRAZ DE SOUZA
author CABRINI FERRAZ DE SOUZA
spellingShingle CABRINI FERRAZ DE SOUZA
DEVELOPMENT OF CAPILLARY ELECTROPHORESIS BASED METHODS WITH DIFFERENT DETECTION APPROACHES FOR DETERMINATION OF ORGANOTINS, STROBILURINS AND AMINOGLYCOSIDES
author_sort CABRINI FERRAZ DE SOUZA
title DEVELOPMENT OF CAPILLARY ELECTROPHORESIS BASED METHODS WITH DIFFERENT DETECTION APPROACHES FOR DETERMINATION OF ORGANOTINS, STROBILURINS AND AMINOGLYCOSIDES
title_short DEVELOPMENT OF CAPILLARY ELECTROPHORESIS BASED METHODS WITH DIFFERENT DETECTION APPROACHES FOR DETERMINATION OF ORGANOTINS, STROBILURINS AND AMINOGLYCOSIDES
title_full DEVELOPMENT OF CAPILLARY ELECTROPHORESIS BASED METHODS WITH DIFFERENT DETECTION APPROACHES FOR DETERMINATION OF ORGANOTINS, STROBILURINS AND AMINOGLYCOSIDES
title_fullStr DEVELOPMENT OF CAPILLARY ELECTROPHORESIS BASED METHODS WITH DIFFERENT DETECTION APPROACHES FOR DETERMINATION OF ORGANOTINS, STROBILURINS AND AMINOGLYCOSIDES
title_full_unstemmed DEVELOPMENT OF CAPILLARY ELECTROPHORESIS BASED METHODS WITH DIFFERENT DETECTION APPROACHES FOR DETERMINATION OF ORGANOTINS, STROBILURINS AND AMINOGLYCOSIDES
title_sort development of capillary electrophoresis based methods with different detection approaches for determination of organotins, strobilurins and aminoglycosides
publisher PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO
publishDate 2013
url http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=23181@1
http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=23181@2
work_keys_str_mv AT cabriniferrazdesouza developmentofcapillaryelectrophoresisbasedmethodswithdifferentdetectionapproachesfordeterminationoforganotinsstrobilurinsandaminoglycosides
AT cabriniferrazdesouza desenvolvimentodemetodosbaseadosnaeletroforesecapilarcomdiferentesabordagensdedeteccaoparadeterminacaodeorganoestanhosestrobilurinaseaminoglicosideos
_version_ 1718988353989246976
spelling ndltd-IBICT-oai-MAXWELL.puc-rio.br-231812019-03-01T15:41:01Z DEVELOPMENT OF CAPILLARY ELECTROPHORESIS BASED METHODS WITH DIFFERENT DETECTION APPROACHES FOR DETERMINATION OF ORGANOTINS, STROBILURINS AND AMINOGLYCOSIDES DESENVOLVIMENTO DE MÉTODOS BASEADOS NA ELETROFORESE CAPILAR COM DIFERENTES ABORDAGENS DE DETECÇÃO PARA DETERMINAÇÃO DE ORGANOESTANHOS, ESTROBILURINAS E AMINOGLICOSÍDEOS CABRINI FERRAZ DE SOUZA RICARDO QUEIROZ AUCELIO RICARDO QUEIROZ AUCELIO FATIMA VENTURA PEREIRA MEIRELLES RICARDO JORGENSEN CASSELLA TATIANA DILLENBURG SAINT PIERRE MARCONE AUGUSTO LEAL DE OLIVEIRA PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO COORDENAÇÃO DE APERFEIÇOAMENTO DO PESSOAL DE ENSINO SUPERIOR CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO PROGRAMA DE EXCELENCIA ACADEMICA Neste trabalho, métodos baseados em diferentes abordagens em eletroforese capilar (CE) foram propostos. No caso da determinação de compostos organoestanhos ou OTs (difenilestanho e monofenilestanho) em fluidos biológicos, foi usada abordagem de eletroforese capilar por zona (CZE) hifenada com a espectrometria de massas (do tipo quadrupolo) com fonte de plasma indutivamente acoplado (CE-ICP-MS). As condições de análise foram estudadas no modo univariado visando otimizar a composição da solução eletrolítica (tampão acetato 5,0 mmol L(-1), pH 2,8) e obter os parâmetros instrumentais (45 graus Celsius, mais 30 kV e 30 s de tempo de introdução hidrodinâmica de amostra). A solução de complementação foi uma solução aquosa 5,0 mmol L(-1) de NH4NO3 contendo 10 por cento metanol em volume e 1,0 Mg L(-1) de Cspositivo, com pH ajustado para 2,8 com tampão acetato. A vazão dessa solução foi mantida em 40 ML min(-1). Os OTs foram diluídos em solução de metanol:tampão acetato de sódio 50:50 por cento v/v ou apenas em tampão acetato de sódio pH 2,8. As condições de detecção do ICP-MS foram ajustadas em 1200 W, 15 L min(-1) de vazão de argônio para formação do plasma, 1 L min(-1) de vazão de argônio auxiliar. A vazão de argônio do nebulizador foi ajustada diariamente. Os isótopos de estanho 120Sn e 118Sn foram monitorados, assim como o 133Cspositivo para controlar a eficiência e estabilidade do processo de nebulização. A resposta linear do método ficou entre 0,050 a 2,0 mg L(-1) de Sn (0,42 a 17 Mmol L-(1)). Os limites de detecção (LOD) e de quantificação (LOQ) em termos de Sn foram de 15 Mg L(-1) (0,13 Mmol L(-1)) e 50 Mg L-1 (0,42 Mmol L(-1)), calculados utilizando a menor concentração dos picos dos analitos que podem ser diferenciados do sinal de fundo. A repetibilidade para o tempo de migração e área dos picos ficou próximo a 5 por cento. O método foi aplicado na análise de urina, sangue total e plasma fortificados com os OTs. Recuperações entre 75 e 95 por cento foram obtidas. No caso da determinação de sete pesticidas da classe das estrobilurinas (azoxistrobina, 9 dimoxistrobina, fluoxastrobina, picoxistrobina, piraclostrobina, trifloxistrobina e kresoxim-metil) em sopas infantis, foi usada a cromatografia eletrocinética capilar micelar (MEKC) com detecção fotométrica (no UV) com capilar de caminho óptico estendido. Um estudo multivariado, usando um planejamento 33 Box Behnken, indicou que a melhor separação para os pesticidas foi com solução aquosa de eletrólito composto por tampão tetraborato de sódio (5,1 mmol L(-1), pH 9,0) contendo 51 mmol L(-1) de dodecil sulfato de sódio (SDS) e 24 por cento acetonitrila (ACN) em volume. As condições instrumentais foram 25 C e mais 30 kV de diferença de potencial aplicada, 45 s de tempo de introdução hidrodinâmica de amostra e detecção em 210 nm. Para aumentar o poder de detecção, foi usada a concentração dos analitos no capilar. Para tal, as soluções de padrões e amostras foram dissolvidas em solução tampão tetraborato de sódio 45 mmol L(-1): acetonitrila 80:20 por cento v/v. As curvas analíticas apresentaram comportamento linear e os valores de LOD ficaram entre 7,0 Mg L(-1) ou 18 nmol L(-1) (piraclostrobina) a 15 Mg L-1 ou 33 nmol L(-1) (fluoxastrobina). Os valores de LOQ ficaram entre 21 Mg L(-1) ou 54 nmol L(-1) (piraclostrobina) a 45 Mg L(-1) ou 98 nmol L(-1) (fluoxastrobina). A repetibilidade ficou entre 1,7 a 7,9 por cento para a área de pico e entre 0,25 a 0,71 por cento para o tempo de migração. A precisão intermediária, avaliada com análises realizadas em diferentes dias, apresentou valores entre 1,3 a 5,3 por cento para a área de pico e entre 0,06 a 0,90 por cento para o tempo de migração. O método foi aplicado na análise de sopas prontas infantis fortificadas com as estrobilurinas. Os pesticidas foram extraídos aplicando o método QuEChERS com ajuste de pH com tampão acetato e limpeza com extração em fase sólida dispersiva. Os resultados das análises obtidos c In this work, analytical methods based on different approaches using capillary electrophoresis (CE) have been proposed. For the determination of organotins or OTs (diphenyltin and monophenyltin) in biological fluids, the separation using capillary zone electrophoresis (CZE) was applied using tandem with inductively coupled plasma mass spectrometry (CE-ICP-MS). The conditions for the analysis were optimized in an unvaried way aiming to find the conditions for the electrolyte solution (acetate buffer, 5.0 mmol L (-1), pH 2.8) and the employed instrumental parameters (45C, 30 kV and 30 s of the time for hydrodynamic introduction of the sample). A complementary solution was composed by NH4NO3 5.0 mmol L(-1), 10 por cento v/v of methanol and 1.0 g L(-1) of Cspositive in acetate buffer with pH adjusted to 2.8. The flow of this solution was set to 40 ML min(-1). The OTs were diluted either in a methanol: acetate buffer 50:50 por cento v/v solution or only in sodium acetate buffer pH 2.8. The conditions for detection by ICP-MS were set to 1200 W, 15 L min(-1) for the Ar plasma flow and 1,0 L min(-1) for the auxiliary Ar. The nebulizer Ar flow was adjusted daily. The monitored tin isotopes were 120Sn 118Sn. The isotope 133Cs was also monitored in order to control the efficiency and stability of the nebulization. The method presented a linear response between 0.05 and 2.0 mg L(-1) (0.42 a 17 Mmol L(-1)) for Sn. The value for the limits of detection (LOD) and for the limits of quantification (LOQ) for Sn were 15 Mg L(-1) (0.13 Mmol L-1) e 50 Mg L(-1) (0.42 Mmol L(-1)), calculated based on the lowest concentration of the analyte peaks that can be differentiated from the background signal. The repeatability for migration time and peak area was approximately 5 per cent. The method was applied in the analysis of organotin fortified blood and urine samples with recoveries between 75 and 95 per cent. In the case of the determination of seven strobilurin class pesticides (azoxystrobin, dimoxystrobin, fluoxastrobin, picoxystrobin, pyraclostrobin, trifloxystrobin and kresoxim-methyl) in baby food (vegetable and fruit soups), 12 the micellar electrokinetic capillary chromatography (MEKC) was used using photometric detection (UV) in a capillary with extended optical path. A multivariate study, with 33 Box Behnken design, indicated the best composition for the electrolytic solution to separate the seven pesticides: a sodium tetraborate buffer (5.1 mmol L(-1), pH 9.0) solution containing 51 mmol L(-1) sodium dodecyl sulfate and acetonitrile (24 por cento in volume). The instrumental conditions were 25C, 30 kV of applied voltage, 45 s for hydrodynamic introduction of the sample and detection at 210 nm. To increase the detection power, the concentration of the analytes into the capillary was used by using the Normal Stacking Mode. For this purpose, the solutions of standards and samples were prepared in 45 mmol L(-1) sodium tetraborate buffer solution: acetonitrile 80:20 por cento v/v. The analytical curves presented a linear behavior and the LOD values were between 7.0 Mg L (-1) or 18 nmol L(-1) (pyraclostrobin) to 15 Mg L(-1) or 33 nmol L(-1) (fluoxastrobin). The LOQ values were between 21 Mg L(-1) or 54 nmol L(-1) (pyraclostrobin) a 45 Mg L(-1) ou 98 nmol L(-1) (fluoxastrobin). The repeatability was between 1.7 to 7.9 por cento for the peak area and between 0.25 to 0.71 por cento for the migration time. The intermediate precision, evaluated by the analysis performed in different days were between 1.3 to 5.3 por cento for the peak area and between 0.06 and 0.90 per cent for the migration time. The method was applied in the analysis of baby food spiked with strobilurin. Pesticides were extracted using the QuEChERS method with pH adjustment with acetate buffer and clean-up using the dispersive solid phase extraction. The analysis results were statistically identical to those obtained with a chromatographic method adapted from the literature. The CZE separation mode was chosen to evaluate the potential of the indirect determination of ami 2013-09-30 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/doctoralThesis http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=23181@1 http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=23181@2 por info:eu-repo/semantics/openAccess PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO PPG EM QUÍMICA PUC-Rio BR reponame:Repositório Institucional da PUC_RIO instname:Pontifícia Universidade Católica do Rio de Janeiro instacron:PUC_RIO