Polymer coatings to improve host response to implanted neural electrodes

Neural electrodes are an important part of brain-machine interface devices that can restore functionality to patients with sensory and movement impairments including spinal cord injury and limb loss. Currently, chronically implanted neural electrodes induce an unfavorable tissue response which inclu...

Full description

Bibliographic Details
Main Author: Gutowski, Stacie Marie
Other Authors: García, Andrés
Format: Others
Language:en_US
Published: Georgia Institute of Technology 2015
Subjects:
PEG
Online Access:http://hdl.handle.net/1853/54007
id ndltd-GATECH-oai-smartech.gatech.edu-1853-54007
record_format oai_dc
spelling ndltd-GATECH-oai-smartech.gatech.edu-1853-540072015-12-03T04:38:01ZPolymer coatings to improve host response to implanted neural electrodesGutowski, Stacie MarieNeural electrodePolymerPEGHost responseAnti-inflammatoryNeural electrodes are an important part of brain-machine interface devices that can restore functionality to patients with sensory and movement impairments including spinal cord injury and limb loss. Currently, chronically implanted neural electrodes induce an unfavorable tissue response which includes inflammation, scar formation, and neuronal cell death, eventually causing loss of electrode functionality in the long term. The objective of this research was to develop a coating to improve the tissue response to implanted neural electrodes. The hypothesis was that coating the surface of neural electrodes with a non-fouling, anti-inflammatory coating would cause reduced inflammation and a better tissue response to the implanted electrode. We developed a polymer coating with non-fouling characteristics, incorporated an anti-inflammatory agent, and engineered a stimulus-responsive degradable portion for on-demand release of the anti-inflammatory agent in response to inflammatory stimuli. We characterized the coating using XPS and ellipsometry, and analyzed cell adhesion, cell spreading, and cytokine release in vitro. We analyzed the in vivo tissue response using immunohistochemistry and microarray qRT-PCR. Although no differences were observed among the samples for inflammatory cell markers, lower IgG penetration into the tissue around PEG + IL-1Ra coated electrodes suggests an improvement in BBB integrity. Gene expression analysis showed higher expression of IL-6 and MMP-2 around PEG + IL-1Ra samples, as well as an increase in CNTF expression, an important marker for neuronal survival. An important finding from this research is the increased neuronal survival around coated electrodes compared to uncoated controls, which is a significant finding as neuronal survival near the implant interface is an essential part of maintaining electrode functionality.Georgia Institute of TechnologyGarcía, Andrés2015-09-21T15:52:26Z2015-09-22T05:30:07Z2014-082014-06-18August 20142015-09-21T15:52:26ZDissertationapplication/pdfhttp://hdl.handle.net/1853/54007en_US
collection NDLTD
language en_US
format Others
sources NDLTD
topic Neural electrode
Polymer
PEG
Host response
Anti-inflammatory
spellingShingle Neural electrode
Polymer
PEG
Host response
Anti-inflammatory
Gutowski, Stacie Marie
Polymer coatings to improve host response to implanted neural electrodes
description Neural electrodes are an important part of brain-machine interface devices that can restore functionality to patients with sensory and movement impairments including spinal cord injury and limb loss. Currently, chronically implanted neural electrodes induce an unfavorable tissue response which includes inflammation, scar formation, and neuronal cell death, eventually causing loss of electrode functionality in the long term. The objective of this research was to develop a coating to improve the tissue response to implanted neural electrodes. The hypothesis was that coating the surface of neural electrodes with a non-fouling, anti-inflammatory coating would cause reduced inflammation and a better tissue response to the implanted electrode. We developed a polymer coating with non-fouling characteristics, incorporated an anti-inflammatory agent, and engineered a stimulus-responsive degradable portion for on-demand release of the anti-inflammatory agent in response to inflammatory stimuli. We characterized the coating using XPS and ellipsometry, and analyzed cell adhesion, cell spreading, and cytokine release in vitro. We analyzed the in vivo tissue response using immunohistochemistry and microarray qRT-PCR. Although no differences were observed among the samples for inflammatory cell markers, lower IgG penetration into the tissue around PEG + IL-1Ra coated electrodes suggests an improvement in BBB integrity. Gene expression analysis showed higher expression of IL-6 and MMP-2 around PEG + IL-1Ra samples, as well as an increase in CNTF expression, an important marker for neuronal survival. An important finding from this research is the increased neuronal survival around coated electrodes compared to uncoated controls, which is a significant finding as neuronal survival near the implant interface is an essential part of maintaining electrode functionality.
author2 García, Andrés
author_facet García, Andrés
Gutowski, Stacie Marie
author Gutowski, Stacie Marie
author_sort Gutowski, Stacie Marie
title Polymer coatings to improve host response to implanted neural electrodes
title_short Polymer coatings to improve host response to implanted neural electrodes
title_full Polymer coatings to improve host response to implanted neural electrodes
title_fullStr Polymer coatings to improve host response to implanted neural electrodes
title_full_unstemmed Polymer coatings to improve host response to implanted neural electrodes
title_sort polymer coatings to improve host response to implanted neural electrodes
publisher Georgia Institute of Technology
publishDate 2015
url http://hdl.handle.net/1853/54007
work_keys_str_mv AT gutowskistaciemarie polymercoatingstoimprovehostresponsetoimplantedneuralelectrodes
_version_ 1718144757038841856