Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry

The effective dose equivalent, H (or the effective dose, E ) to an individual is the primary limiting quantity in radiation protection. However, techniques for measuring H for neutrons have not been fully developed. In this regard a new tissue equivalent proportional counter (TEPC) based on a gas el...

Full description

Bibliographic Details
Main Author: Seydaliev, Marat Radikovich
Published: Georgia Institute of Technology 2007
Subjects:
Online Access:http://hdl.handle.net/1853/14607
id ndltd-GATECH-oai-smartech.gatech.edu-1853-14607
record_format oai_dc
spelling ndltd-GATECH-oai-smartech.gatech.edu-1853-146072013-01-07T20:16:51ZDevelopment and Test of a GEM-Based TEPC for Neutron Protection DosimetrySeydaliev, Marat RadikovichDosimetryRadiationNeutron detectionInstrumentsGas electron multiplierTissue-equivalent proportional counterRadiation Safety measuresNeutrons MeasurementRadiation dosimetryThe effective dose equivalent, H (or the effective dose, E ) to an individual is the primary limiting quantity in radiation protection. However, techniques for measuring H for neutrons have not been fully developed. In this regard a new tissue equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) for measuring H*(10), which is a conservative estimate of H, for neutrons was designed and constructed. The deposited energy distribution for two different neutron sources (a Cf-252 source and a AmBe source) was measured using the new TEPC. The measurements were performed using two different proportional gases: P-10 gas and a propane-based tissue equivalent gas at various pressures. A computer simulation of the new TEPC, based on the Monte Carlo method, was performed in order to obtain the pulse height distributions for the two neutron sources. The simulated results and the measured results were compared. Results show that the experimental results agree with the computational results within 20% of accuracy for both Cf-252 and AmBe neutron sources. A new model GEM-based TEPC was developed for use in obtaining H*(10). The value of H*(10) for the Cf-252 source and for the AmBe source using experimental measurements was obtained. These results are presented in this study. The study shows that the GEM-based TEPC can successfully estimate H*(10). With these results and some refinements, this GEM-based TEPC can directly be used as a neutron rem meter.Georgia Institute of Technology2007-05-25T17:39:48Z2007-05-25T17:39:48Z2007-02-12Dissertationhttp://hdl.handle.net/1853/14607
collection NDLTD
sources NDLTD
topic Dosimetry
Radiation
Neutron detection
Instruments
Gas electron multiplier
Tissue-equivalent proportional counter
Radiation Safety measures
Neutrons Measurement
Radiation dosimetry
spellingShingle Dosimetry
Radiation
Neutron detection
Instruments
Gas electron multiplier
Tissue-equivalent proportional counter
Radiation Safety measures
Neutrons Measurement
Radiation dosimetry
Seydaliev, Marat Radikovich
Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry
description The effective dose equivalent, H (or the effective dose, E ) to an individual is the primary limiting quantity in radiation protection. However, techniques for measuring H for neutrons have not been fully developed. In this regard a new tissue equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) for measuring H*(10), which is a conservative estimate of H, for neutrons was designed and constructed. The deposited energy distribution for two different neutron sources (a Cf-252 source and a AmBe source) was measured using the new TEPC. The measurements were performed using two different proportional gases: P-10 gas and a propane-based tissue equivalent gas at various pressures. A computer simulation of the new TEPC, based on the Monte Carlo method, was performed in order to obtain the pulse height distributions for the two neutron sources. The simulated results and the measured results were compared. Results show that the experimental results agree with the computational results within 20% of accuracy for both Cf-252 and AmBe neutron sources. A new model GEM-based TEPC was developed for use in obtaining H*(10). The value of H*(10) for the Cf-252 source and for the AmBe source using experimental measurements was obtained. These results are presented in this study. The study shows that the GEM-based TEPC can successfully estimate H*(10). With these results and some refinements, this GEM-based TEPC can directly be used as a neutron rem meter.
author Seydaliev, Marat Radikovich
author_facet Seydaliev, Marat Radikovich
author_sort Seydaliev, Marat Radikovich
title Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry
title_short Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry
title_full Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry
title_fullStr Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry
title_full_unstemmed Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry
title_sort development and test of a gem-based tepc for neutron protection dosimetry
publisher Georgia Institute of Technology
publishDate 2007
url http://hdl.handle.net/1853/14607
work_keys_str_mv AT seydalievmaratradikovich developmentandtestofagembasedtepcforneutronprotectiondosimetry
_version_ 1716474647969529856