Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry
The effective dose equivalent, H (or the effective dose, E ) to an individual is the primary limiting quantity in radiation protection. However, techniques for measuring H for neutrons have not been fully developed. In this regard a new tissue equivalent proportional counter (TEPC) based on a gas el...
Main Author: | |
---|---|
Published: |
Georgia Institute of Technology
2007
|
Subjects: | |
Online Access: | http://hdl.handle.net/1853/14607 |
id |
ndltd-GATECH-oai-smartech.gatech.edu-1853-14607 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-GATECH-oai-smartech.gatech.edu-1853-146072013-01-07T20:16:51ZDevelopment and Test of a GEM-Based TEPC for Neutron Protection DosimetrySeydaliev, Marat RadikovichDosimetryRadiationNeutron detectionInstrumentsGas electron multiplierTissue-equivalent proportional counterRadiation Safety measuresNeutrons MeasurementRadiation dosimetryThe effective dose equivalent, H (or the effective dose, E ) to an individual is the primary limiting quantity in radiation protection. However, techniques for measuring H for neutrons have not been fully developed. In this regard a new tissue equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) for measuring H*(10), which is a conservative estimate of H, for neutrons was designed and constructed. The deposited energy distribution for two different neutron sources (a Cf-252 source and a AmBe source) was measured using the new TEPC. The measurements were performed using two different proportional gases: P-10 gas and a propane-based tissue equivalent gas at various pressures. A computer simulation of the new TEPC, based on the Monte Carlo method, was performed in order to obtain the pulse height distributions for the two neutron sources. The simulated results and the measured results were compared. Results show that the experimental results agree with the computational results within 20% of accuracy for both Cf-252 and AmBe neutron sources. A new model GEM-based TEPC was developed for use in obtaining H*(10). The value of H*(10) for the Cf-252 source and for the AmBe source using experimental measurements was obtained. These results are presented in this study. The study shows that the GEM-based TEPC can successfully estimate H*(10). With these results and some refinements, this GEM-based TEPC can directly be used as a neutron rem meter.Georgia Institute of Technology2007-05-25T17:39:48Z2007-05-25T17:39:48Z2007-02-12Dissertationhttp://hdl.handle.net/1853/14607 |
collection |
NDLTD |
sources |
NDLTD |
topic |
Dosimetry Radiation Neutron detection Instruments Gas electron multiplier Tissue-equivalent proportional counter Radiation Safety measures Neutrons Measurement Radiation dosimetry |
spellingShingle |
Dosimetry Radiation Neutron detection Instruments Gas electron multiplier Tissue-equivalent proportional counter Radiation Safety measures Neutrons Measurement Radiation dosimetry Seydaliev, Marat Radikovich Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry |
description |
The effective dose equivalent, H (or the effective dose, E ) to an individual is the primary limiting quantity in radiation protection. However, techniques for measuring H for neutrons have not been fully developed. In this regard a new tissue equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) for measuring H*(10), which is a conservative estimate of H, for neutrons was designed and constructed.
The deposited energy distribution for two different neutron sources (a Cf-252 source and a AmBe source) was measured using the new TEPC. The measurements were performed using two different proportional gases: P-10 gas and a propane-based tissue equivalent gas at various pressures. A computer simulation of the new TEPC, based on the Monte Carlo method, was performed in order to obtain the pulse height distributions for the two neutron sources. The simulated results and the measured results were compared. Results show that the experimental results agree with the computational results within 20% of accuracy for both Cf-252 and AmBe neutron sources.
A new model GEM-based TEPC was developed for use in obtaining H*(10). The value of H*(10) for the Cf-252 source and for the AmBe source using experimental measurements was obtained. These results are presented in this study. The study shows that the GEM-based TEPC can successfully estimate H*(10). With these results and some refinements, this GEM-based TEPC can directly be used as a neutron rem meter. |
author |
Seydaliev, Marat Radikovich |
author_facet |
Seydaliev, Marat Radikovich |
author_sort |
Seydaliev, Marat Radikovich |
title |
Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry |
title_short |
Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry |
title_full |
Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry |
title_fullStr |
Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry |
title_full_unstemmed |
Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry |
title_sort |
development and test of a gem-based tepc for neutron protection dosimetry |
publisher |
Georgia Institute of Technology |
publishDate |
2007 |
url |
http://hdl.handle.net/1853/14607 |
work_keys_str_mv |
AT seydalievmaratradikovich developmentandtestofagembasedtepcforneutronprotectiondosimetry |
_version_ |
1716474647969529856 |