Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors
In this thesis methods of calibration of the electromagnetic calorimeter of the BABAR experiment will be introduced. Additionally a method was developed to take into account the different energy losses between the edges and centres of the crystals. An improvement of the energy resolution of photons...
Main Author: | |
---|---|
Other Authors: | |
Format: | Doctoral Thesis |
Language: | deu |
Published: |
Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden
2003
|
Subjects: | |
Online Access: | http://nbn-resolving.de/urn:nbn:de:swb:14-1073482617796-31653 http://nbn-resolving.de/urn:nbn:de:swb:14-1073482617796-31653 http://www.qucosa.de/fileadmin/data/qucosa/documents/1094/1073482617796-3165.pdf |
id |
ndltd-DRESDEN-oai-qucosa.de-swb-14-1073482617796-31653 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-DRESDEN-oai-qucosa.de-swb-14-1073482617796-316532013-01-07T19:49:41Z Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors Maly, Enrico BABAR Hadronen Kalibrierung Kalorimeter pi0 BABAR calibration calorimeter hadrons pi0 ddc:530 rvk:UO 6290 BABAR-Detektor Hadron Kalibrieren Kalorimeter Neutrales Pion In this thesis methods of calibration of the electromagnetic calorimeter of the BABAR experiment will be introduced. Additionally a method was developed to take into account the different energy losses between the edges and centres of the crystals. An improvement of the energy resolution of photons was achieved by 15%, depending on the energy. For Y(4S) and continuum events a momentum spectrum of inclusively produced neutral pions (Y(4S) -> pi0 X and e+e- -> q anti-q -> pi0 X, respectively) was determined. For continuum events also a momentum depending angle distribution was determined. From these distributions the average number of produced pi0 per event was calculated. The results for B decays and continuum events are n(B) =2,268+-0,008+-0,115 and n(Continuum)=3,388+-0,005+-0,172, respectively. These values were compared with Monte Carlo simulations and with other analyses. In dieser Arbeit werden die Kalibrierungsmethoden des elektromagnetischen Kalorimeters des BABAR-Experiments vorgestellt. Entwickelt wurde dabei eine Methode, die die unterschiedlichen Energieverluste zwischen Kristallrändern und Kristallmitten berücksichtigt. Es wurde dabei eine Verbesserung der Energieauflösung von Photonen, abhängig von der Energie, von bis zu 15% erreicht. Für Y(4S)- und Kontinuumsereignisse wurden die Impulsspektren und für letztere die impulsabhängigen Richtungsverteilungen inklusiv produzierter neutraler Pionen (Y(4S) -> pi0 X bzw. e+e- -> q anti-q -> pi0 X) bestimmt. Aus diesen Verteilungen wurde die mittleren Anzahl erzeugter pi0 pro Ereignis ermittelt. Für B-Zerfälle bzw. Kontinuumsereignisse ergaben sich n(B) =2,268+-0,008+-0,115 bzw. n(Kontinuum)=3,388+-0,005+-0,172. Diese Werte wurden mit Monte-Carlo-Simulationen und mit anderen Analysen verglichen. Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden Technische Universität Dresden, Mathematik und Naturwissenschaften, Physik, Institut für Kern- und Teilchenphysik Prof. Dr. Klaus R. Schubert Prof. Dr. Klaus R. Schubert Dr. Sven Menke Prof. Dr. Bernhard Spaan 2003-12-07 doc-type:doctoralThesis application/pdf http://nbn-resolving.de/urn:nbn:de:swb:14-1073482617796-31653 urn:nbn:de:swb:14-1073482617796-31653 PPN109760603 http://www.qucosa.de/fileadmin/data/qucosa/documents/1094/1073482617796-3165.pdf deu |
collection |
NDLTD |
language |
deu |
format |
Doctoral Thesis |
sources |
NDLTD |
topic |
BABAR Hadronen Kalibrierung Kalorimeter pi0 BABAR calibration calorimeter hadrons pi0 ddc:530 rvk:UO 6290 BABAR-Detektor Hadron Kalibrieren Kalorimeter Neutrales Pion |
spellingShingle |
BABAR Hadronen Kalibrierung Kalorimeter pi0 BABAR calibration calorimeter hadrons pi0 ddc:530 rvk:UO 6290 BABAR-Detektor Hadron Kalibrieren Kalorimeter Neutrales Pion Maly, Enrico Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors |
description |
In this thesis methods of calibration of the electromagnetic calorimeter of the BABAR experiment will be introduced. Additionally a method was developed to take into account the different energy losses between the edges and centres of the crystals. An improvement of the energy resolution of photons was achieved by 15%, depending on the energy. For Y(4S) and continuum events a momentum spectrum of inclusively produced neutral pions (Y(4S) -> pi0 X and e+e- -> q anti-q -> pi0 X, respectively) was determined. For continuum events also a momentum depending angle distribution was determined. From these distributions the average number of produced pi0 per event was calculated. The results for B decays and continuum events are n(B) =2,268+-0,008+-0,115 and n(Continuum)=3,388+-0,005+-0,172, respectively. These values were compared with Monte Carlo simulations and with other analyses. === In dieser Arbeit werden die Kalibrierungsmethoden des elektromagnetischen Kalorimeters des BABAR-Experiments vorgestellt. Entwickelt wurde dabei eine Methode, die die unterschiedlichen Energieverluste zwischen Kristallrändern und Kristallmitten berücksichtigt. Es wurde dabei eine Verbesserung der Energieauflösung von Photonen, abhängig von der Energie, von bis zu 15% erreicht. Für Y(4S)- und Kontinuumsereignisse wurden die Impulsspektren und für letztere die impulsabhängigen Richtungsverteilungen inklusiv produzierter neutraler Pionen (Y(4S) -> pi0 X bzw. e+e- -> q anti-q -> pi0 X) bestimmt. Aus diesen Verteilungen wurde die mittleren Anzahl erzeugter pi0 pro Ereignis ermittelt. Für B-Zerfälle bzw. Kontinuumsereignisse ergaben sich n(B) =2,268+-0,008+-0,115 bzw. n(Kontinuum)=3,388+-0,005+-0,172. Diese Werte wurden mit Monte-Carlo-Simulationen und mit anderen Analysen verglichen. |
author2 |
Technische Universität Dresden, Mathematik und Naturwissenschaften, Physik, Institut für Kern- und Teilchenphysik |
author_facet |
Technische Universität Dresden, Mathematik und Naturwissenschaften, Physik, Institut für Kern- und Teilchenphysik Maly, Enrico |
author |
Maly, Enrico |
author_sort |
Maly, Enrico |
title |
Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors |
title_short |
Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors |
title_full |
Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors |
title_fullStr |
Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors |
title_full_unstemmed |
Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors |
title_sort |
untersuchung neutraler pi-mesonen mit dem elektromagnetischen kalorimeter des babar-detektors |
publisher |
Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden |
publishDate |
2003 |
url |
http://nbn-resolving.de/urn:nbn:de:swb:14-1073482617796-31653 http://nbn-resolving.de/urn:nbn:de:swb:14-1073482617796-31653 http://www.qucosa.de/fileadmin/data/qucosa/documents/1094/1073482617796-3165.pdf |
work_keys_str_mv |
AT malyenrico untersuchungneutralerpimesonenmitdemelektromagnetischenkalorimeterdesbabardetektors |
_version_ |
1716470848240484352 |