Limitations of the Pulse-Shape Technique for Particle Discrimination in Planar Si Detectors

Limitations of the pulse-shape discrimination (PSD) technique - a promising method to identify the charged particIes stopped in planar Si-detectors - have been investigated. The particle resolution turned out to be basically determined by resistivity fluctuations in the buk silicon which cause the c...

Full description

Bibliographic Details
Main Authors: Wolski, D., Cederkäll, J., Pausch, G., Moszynski, M., Schubart, R., Rohr, P., Lampert, M.-O., Grawe, H., Klamra, W., Seidel, W.
Other Authors: Forschungszentrum Rossendorf, Institut für Strahlenphysik
Format: Others
Language:English
Published: Forschungszentrum Dresden 2010
Online Access:http://nbn-resolving.de/urn:nbn:de:bsz:d120-qucosa-31373
http://nbn-resolving.de/urn:nbn:de:bsz:d120-qucosa-31373
http://www.qucosa.de/fileadmin/data/qucosa/documents/3137/732.pdf
id ndltd-DRESDEN-oai-qucosa.de-bsz-d120-qucosa-31373
record_format oai_dc
spelling ndltd-DRESDEN-oai-qucosa.de-bsz-d120-qucosa-313732013-01-07T19:53:05Z Limitations of the Pulse-Shape Technique for Particle Discrimination in Planar Si Detectors Wolski, D. Cederkäll, J. Pausch, G. Moszynski, M. Schubart, R. Rohr, P. Lampert, M.-O. Grawe, H. Klamra, W. Seidel, W. Limitations of the pulse-shape discrimination (PSD) technique - a promising method to identify the charged particIes stopped in planar Si-detectors - have been investigated. The particle resolution turned out to be basically determined by resistivity fluctuations in the buk silicon which cause the charge-collection time to depend on the point of impact. Detector maps showing these fluctuations have been measured and are discussed. Furthermore we present a simple method to test the performance of detectors with respect to PSD. Another limitation of the PSD technique is the finite energy threshold for particle identification. This threshold is caused by an unexpected decrease of the total charge-collection time for ions with a short range, in spite of the fact that the particle tracks are located in a region of very low electric field. Forschungszentrum Dresden Forschungszentrum Rossendorf, Institut für Strahlenphysik 2010-03-31 doc-type:report application/pdf http://nbn-resolving.de/urn:nbn:de:bsz:d120-qucosa-31373 urn:nbn:de:bsz:d120-qucosa-31373 http://www.qucosa.de/fileadmin/data/qucosa/documents/3137/732.pdf Forschungszentrum Rossendorf; FZR-157 Preprint eng dcterms:isPartOf:Wissenschaftlich-technische Berichte ; FZR-157
collection NDLTD
language English
format Others
sources NDLTD
description Limitations of the pulse-shape discrimination (PSD) technique - a promising method to identify the charged particIes stopped in planar Si-detectors - have been investigated. The particle resolution turned out to be basically determined by resistivity fluctuations in the buk silicon which cause the charge-collection time to depend on the point of impact. Detector maps showing these fluctuations have been measured and are discussed. Furthermore we present a simple method to test the performance of detectors with respect to PSD. Another limitation of the PSD technique is the finite energy threshold for particle identification. This threshold is caused by an unexpected decrease of the total charge-collection time for ions with a short range, in spite of the fact that the particle tracks are located in a region of very low electric field.
author2 Forschungszentrum Rossendorf, Institut für Strahlenphysik
author_facet Forschungszentrum Rossendorf, Institut für Strahlenphysik
Wolski, D.
Cederkäll, J.
Pausch, G.
Moszynski, M.
Schubart, R.
Rohr, P.
Lampert, M.-O.
Grawe, H.
Klamra, W.
Seidel, W.
author Wolski, D.
Cederkäll, J.
Pausch, G.
Moszynski, M.
Schubart, R.
Rohr, P.
Lampert, M.-O.
Grawe, H.
Klamra, W.
Seidel, W.
spellingShingle Wolski, D.
Cederkäll, J.
Pausch, G.
Moszynski, M.
Schubart, R.
Rohr, P.
Lampert, M.-O.
Grawe, H.
Klamra, W.
Seidel, W.
Limitations of the Pulse-Shape Technique for Particle Discrimination in Planar Si Detectors
author_sort Wolski, D.
title Limitations of the Pulse-Shape Technique for Particle Discrimination in Planar Si Detectors
title_short Limitations of the Pulse-Shape Technique for Particle Discrimination in Planar Si Detectors
title_full Limitations of the Pulse-Shape Technique for Particle Discrimination in Planar Si Detectors
title_fullStr Limitations of the Pulse-Shape Technique for Particle Discrimination in Planar Si Detectors
title_full_unstemmed Limitations of the Pulse-Shape Technique for Particle Discrimination in Planar Si Detectors
title_sort limitations of the pulse-shape technique for particle discrimination in planar si detectors
publisher Forschungszentrum Dresden
publishDate 2010
url http://nbn-resolving.de/urn:nbn:de:bsz:d120-qucosa-31373
http://nbn-resolving.de/urn:nbn:de:bsz:d120-qucosa-31373
http://www.qucosa.de/fileadmin/data/qucosa/documents/3137/732.pdf
work_keys_str_mv AT wolskid limitationsofthepulseshapetechniqueforparticlediscriminationinplanarsidetectors
AT cederkallj limitationsofthepulseshapetechniqueforparticlediscriminationinplanarsidetectors
AT pauschg limitationsofthepulseshapetechniqueforparticlediscriminationinplanarsidetectors
AT moszynskim limitationsofthepulseshapetechniqueforparticlediscriminationinplanarsidetectors
AT schubartr limitationsofthepulseshapetechniqueforparticlediscriminationinplanarsidetectors
AT rohrp limitationsofthepulseshapetechniqueforparticlediscriminationinplanarsidetectors
AT lampertmo limitationsofthepulseshapetechniqueforparticlediscriminationinplanarsidetectors
AT graweh limitationsofthepulseshapetechniqueforparticlediscriminationinplanarsidetectors
AT klamraw limitationsofthepulseshapetechniqueforparticlediscriminationinplanarsidetectors
AT seidelw limitationsofthepulseshapetechniqueforparticlediscriminationinplanarsidetectors
_version_ 1716471494724288512