TOPFLOW-Experiments on Direct Condensation and Bubble Entrainment
Direct Contact Condensation between steam and water as well as bubble entrainment below the water surface play an important role in different accident scenarios for light water reactors. One example is the emergency core cooling water injection into a two-phase mixture. It has to be considered for e...
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Others |
Language: | English |
Published: |
Helmholtz-Zentrum Dresden - Rossendorf
2016
|
Subjects: | |
Online Access: | http://nbn-resolving.de/urn:nbn:de:bsz:d120-qucosa-197715 http://nbn-resolving.de/urn:nbn:de:bsz:d120-qucosa-197715 http://www.qucosa.de/fileadmin/data/qucosa/documents/19771/HZDR_066t.pdf |
Summary: | Direct Contact Condensation between steam and water as well as bubble entrainment below the water surface play an important role in different accident scenarios for light water reactors. One example is the emergency core cooling water injection into a two-phase mixture. It has to be considered for example to evaluate potential pressurized thermal shock phenomena.
This report documents experiments conducted in flat basin inside the TOPFLOW pressure chamber aiming on the generation of a database useful for CFD model development and validation. It comprises 3 different setups: condensation at a stratified flow of sub-cooled water, condensation at a sub-cooled water jet and a combination of both phenomena with steam bubble entrainment. The documentation includes all details on the experimental set up, on experimental conditions (experimental matrices), on the conduction of the experiments, on measuring techniques used and on data evaluation procedures. In addition, selected results are presented. |
---|