Biologic Fixation of the Electrode Cable of Cochlea Implants

Objectives: To verify the necessity for special surgical techniques or clips for fixation of the electrode cable of a cochlea implant against dislocation, and to test the stability of postoperative biologic cicatrization as the sole and solid anchoring of the cable. Material: Temporal bone experimen...

Full description

Bibliographic Details
Main Authors: Hüttenbrink, Karl-Bernd, Zahnert, Thomas, Vogel, Uwe, Hofmann, Gert
Other Authors: Karger,
Format: Article
Language:English
Published: Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden 2014
Subjects:
Online Access:http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-135236
http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-135236
http://www.qucosa.de/fileadmin/data/qucosa/documents/13523/ORN2000010005213.pdf
id ndltd-DRESDEN-oai-qucosa.de-bsz-14-qucosa-135236
record_format oai_dc
collection NDLTD
language English
format Article
sources NDLTD
topic Biologische Befestigung
Elektrodenkabel
Kochlearimplantat
Cochlea implants
Electrode cable
Fixation
Adhesive
Experiments
ddc:610
rvk:XA 10000
spellingShingle Biologische Befestigung
Elektrodenkabel
Kochlearimplantat
Cochlea implants
Electrode cable
Fixation
Adhesive
Experiments
ddc:610
rvk:XA 10000
Hüttenbrink, Karl-Bernd
Zahnert, Thomas
Vogel, Uwe
Hofmann, Gert
Biologic Fixation of the Electrode Cable of Cochlea Implants
description Objectives: To verify the necessity for special surgical techniques or clips for fixation of the electrode cable of a cochlea implant against dislocation, and to test the stability of postoperative biologic cicatrization as the sole and solid anchoring of the cable. Material: Temporal bone experiments with a simulated connective tissue sheath around conventional (Med El Combi 40+) and prototype (profiled surface) electrode cables. Results and Conclusions: The electrode cable is anchored securely in a sheath of scar tissue, since unphysiologic loads are needed for pulling it out of its anchorage. The drag during one extraction trial with a profiled cable even resulted in the rupture of the cable. These results confirm our confidence in this biologic fixation of the electrode cable inside its postoperative cicatric tissue sheath. More than 80 cochlea implantations with the electrode simply imbedded in a drop of fibrin glue in the posterior tympanotomy never demonstrated a shift of the electrodes in the last 8 years. Therefore, special fixation of the electrode cable with clips or surgical techniques is not necessary. === Fragestellung: Muss das Elektrodenkabel eines Kochlearimplantats durch spezielle operative Techniken oder Halterungen gegen ein Herausrutschen aus der Kochlea gesichert werden, oder genügt die Einscheidung in dem postoperativ sich ausbildenden Narbengewebe für eine ausreichend stabile Fixierung? Material: Felsenbeinexperimente mit einer Simulation der narbigen Einbettung konventioneller und modifizierter (geriffelter Oberfläche) Elektrodenkabel eines Kochlearimplantats (Med El Combi 40+). Ergebnisse und Schlussfolgerungen: Ein Herausziehen eines in simuliertem Narbengewebe eingescheideten Elektrodenkabels gelang erst bei erheblichen, unphysiologischen Kräften; eine Rifflung der Oberfläche des Silikonkabels erhöhte den Reibungswiderstand über die Reissfestigkeit des Kabels. Das Vertrauen in die biologische Fixierung des Elektrodenkabels durch die Verankerung im Narbengewebe ist somit gerechtfertigt, und wird auch durch unsere klinische Erfahrung bestätigt: in über 80 Operationen, bei denen das Kabel des Kochlearimplantats nur durch Einbettung in Fibrinkleber am Rahmen der posterioren Tympanotomie gesichert worden war, liess sich in den letzten 8 Jahren in keinem Fall eine Elektrodenverlagerung nachweisen. Eine gezielte Fixation des Elektrodenkabels durch künstliche Halterungen oder spezielle OP-Techniken erscheint somit nicht erforderlich. === Problématique: Afin d’éviter tout glissement de l’électrode de l’implant cochléaire, est-il préférable d’en assurer la fixation par une technique opératoire particulière ou bien est-il suffisant de gainer l’électrode dans les tissus cicatriciels qui se forment après l’opération? Méthode: Nous avons procédé à des expériences sur le rocher en simulant une inclusion cicatricielle d’un câble-électrode classique (Med El Combi 40+), d’une part, et modifié (surface cannelée), d’autre part. Résultats et conclusion: Une force dépassant les réalités physiologiques a été nécessaire pour retirer le câble-électrode gainé dans les tissus cicatriciels simulés. Le câble avec la surface cannelée s’avérait encore plus résistant: il déchirait même lorsqu’on a essayé de le retirer. Ceci vient donc conforter la confiance que nous avons dans la fixation biologique, c’est-à-dire dans l’ancrage de l’électrode dans les tissus cicatriciels. Une confiance qui est d’ailleurs confirmée par les expériences que nous avons pu faire dans notre clinique. Ainsi, en 8 ans, sur 80 opérations, au cours desquelles le câble de l’implant a été fixé en étant simplement placé dans de la fibrine, dans le cadre d’une tympanotomie postérieure, aucun déplacement de l’électrode n’a été constaté. Par conséquent, il ne s’avère pas nécessaire d’avoir recours à une fixation artificielle ou à une technique opératoire particulière pour assurer le bon maintien de l’électrode === Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG-geförderten) Allianz- bzw. Nationallizenz frei zugänglich.
author2 Karger,
author_facet Karger,
Hüttenbrink, Karl-Bernd
Zahnert, Thomas
Vogel, Uwe
Hofmann, Gert
author Hüttenbrink, Karl-Bernd
Zahnert, Thomas
Vogel, Uwe
Hofmann, Gert
author_sort Hüttenbrink, Karl-Bernd
title Biologic Fixation of the Electrode Cable of Cochlea Implants
title_short Biologic Fixation of the Electrode Cable of Cochlea Implants
title_full Biologic Fixation of the Electrode Cable of Cochlea Implants
title_fullStr Biologic Fixation of the Electrode Cable of Cochlea Implants
title_full_unstemmed Biologic Fixation of the Electrode Cable of Cochlea Implants
title_sort biologic fixation of the electrode cable of cochlea implants
publisher Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden
publishDate 2014
url http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-135236
http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-135236
http://www.qucosa.de/fileadmin/data/qucosa/documents/13523/ORN2000010005213.pdf
work_keys_str_mv AT huttenbrinkkarlbernd biologicfixationoftheelectrodecableofcochleaimplants
AT zahnertthomas biologicfixationoftheelectrodecableofcochleaimplants
AT vogeluwe biologicfixationoftheelectrodecableofcochleaimplants
AT hofmanngert biologicfixationoftheelectrodecableofcochleaimplants
AT huttenbrinkkarlbernd biologischebefestigungdeselektrodenkabelseineskochlearimplantats
AT zahnertthomas biologischebefestigungdeselektrodenkabelseineskochlearimplantats
AT vogeluwe biologischebefestigungdeselektrodenkabelseineskochlearimplantats
AT hofmanngert biologischebefestigungdeselektrodenkabelseineskochlearimplantats
AT huttenbrinkkarlbernd fixationbiologiqueducableelectrodedelimplantcochleaire
AT zahnertthomas fixationbiologiqueducableelectrodedelimplantcochleaire
AT vogeluwe fixationbiologiqueducableelectrodedelimplantcochleaire
AT hofmanngert fixationbiologiqueducableelectrodedelimplantcochleaire
_version_ 1716668206952742912
spelling ndltd-DRESDEN-oai-qucosa.de-bsz-14-qucosa-1352362014-06-06T03:37:47Z Biologic Fixation of the Electrode Cable of Cochlea Implants Biologische Befestigung des Elektrodenkabels eines Kochlearimplantats Fixation biologique du câble-électrode de l’implant cochléaire Hüttenbrink, Karl-Bernd Zahnert, Thomas Vogel, Uwe Hofmann, Gert Biologische Befestigung Elektrodenkabel Kochlearimplantat Cochlea implants Electrode cable Fixation Adhesive Experiments ddc:610 rvk:XA 10000 Objectives: To verify the necessity for special surgical techniques or clips for fixation of the electrode cable of a cochlea implant against dislocation, and to test the stability of postoperative biologic cicatrization as the sole and solid anchoring of the cable. Material: Temporal bone experiments with a simulated connective tissue sheath around conventional (Med El Combi 40+) and prototype (profiled surface) electrode cables. Results and Conclusions: The electrode cable is anchored securely in a sheath of scar tissue, since unphysiologic loads are needed for pulling it out of its anchorage. The drag during one extraction trial with a profiled cable even resulted in the rupture of the cable. These results confirm our confidence in this biologic fixation of the electrode cable inside its postoperative cicatric tissue sheath. More than 80 cochlea implantations with the electrode simply imbedded in a drop of fibrin glue in the posterior tympanotomy never demonstrated a shift of the electrodes in the last 8 years. Therefore, special fixation of the electrode cable with clips or surgical techniques is not necessary. Fragestellung: Muss das Elektrodenkabel eines Kochlearimplantats durch spezielle operative Techniken oder Halterungen gegen ein Herausrutschen aus der Kochlea gesichert werden, oder genügt die Einscheidung in dem postoperativ sich ausbildenden Narbengewebe für eine ausreichend stabile Fixierung? Material: Felsenbeinexperimente mit einer Simulation der narbigen Einbettung konventioneller und modifizierter (geriffelter Oberfläche) Elektrodenkabel eines Kochlearimplantats (Med El Combi 40+). Ergebnisse und Schlussfolgerungen: Ein Herausziehen eines in simuliertem Narbengewebe eingescheideten Elektrodenkabels gelang erst bei erheblichen, unphysiologischen Kräften; eine Rifflung der Oberfläche des Silikonkabels erhöhte den Reibungswiderstand über die Reissfestigkeit des Kabels. Das Vertrauen in die biologische Fixierung des Elektrodenkabels durch die Verankerung im Narbengewebe ist somit gerechtfertigt, und wird auch durch unsere klinische Erfahrung bestätigt: in über 80 Operationen, bei denen das Kabel des Kochlearimplantats nur durch Einbettung in Fibrinkleber am Rahmen der posterioren Tympanotomie gesichert worden war, liess sich in den letzten 8 Jahren in keinem Fall eine Elektrodenverlagerung nachweisen. Eine gezielte Fixation des Elektrodenkabels durch künstliche Halterungen oder spezielle OP-Techniken erscheint somit nicht erforderlich. Problématique: Afin d’éviter tout glissement de l’électrode de l’implant cochléaire, est-il préférable d’en assurer la fixation par une technique opératoire particulière ou bien est-il suffisant de gainer l’électrode dans les tissus cicatriciels qui se forment après l’opération? Méthode: Nous avons procédé à des expériences sur le rocher en simulant une inclusion cicatricielle d’un câble-électrode classique (Med El Combi 40+), d’une part, et modifié (surface cannelée), d’autre part. Résultats et conclusion: Une force dépassant les réalités physiologiques a été nécessaire pour retirer le câble-électrode gainé dans les tissus cicatriciels simulés. Le câble avec la surface cannelée s’avérait encore plus résistant: il déchirait même lorsqu’on a essayé de le retirer. Ceci vient donc conforter la confiance que nous avons dans la fixation biologique, c’est-à-dire dans l’ancrage de l’électrode dans les tissus cicatriciels. Une confiance qui est d’ailleurs confirmée par les expériences que nous avons pu faire dans notre clinique. Ainsi, en 8 ans, sur 80 opérations, au cours desquelles le câble de l’implant a été fixé en étant simplement placé dans de la fibrine, dans le cadre d’une tympanotomie postérieure, aucun déplacement de l’électrode n’a été constaté. Par conséquent, il ne s’avère pas nécessaire d’avoir recours à une fixation artificielle ou à une technique opératoire particulière pour assurer le bon maintien de l’électrode Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG-geförderten) Allianz- bzw. Nationallizenz frei zugänglich. Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden Karger, 2014-02-26 doc-type:article application/pdf http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-135236 urn:nbn:de:bsz:14-qucosa-135236 PPN407614605 http://www.qucosa.de/fileadmin/data/qucosa/documents/13523/ORN2000010005213.pdf Otorhinolaryngol Nova 2000;10:213–216, ISSN: 1014-8221 eng