Static electricity generated during the distribution of gasolene

<p>This research project was undertaken to determine the exact hazard represented by static electricity when it is generated during the distribution of gasolene. "Equivalent electrical circuits" have been utilized which, with the knowledge of the magnitude of charge developed under...

Full description

Bibliographic Details
Main Author: Wouk, Victor
Format: Others
Published: 1942
Online Access:https://thesis.library.caltech.edu/4716/1/Wouk_v_1942.pdf
Wouk, Victor (1942) Static electricity generated during the distribution of gasolene. Dissertation (Ph.D.), California Institute of Technology. doi:10.7907/9HN9-EE76. https://resolver.caltech.edu/CaltechETD:etd-12022004-153844 <https://resolver.caltech.edu/CaltechETD:etd-12022004-153844>
id ndltd-CALTECH-oai-thesis.library.caltech.edu-4716
record_format oai_dc
spelling ndltd-CALTECH-oai-thesis.library.caltech.edu-47162019-12-22T03:08:47Z Static electricity generated during the distribution of gasolene Wouk, Victor <p>This research project was undertaken to determine the exact hazard represented by static electricity when it is generated during the distribution of gasolene. "Equivalent electrical circuits" have been utilized which, with the knowledge of the magnitude of charge developed under different conditions, enable one to predict the voltages that will be present and the subsequent chances of sparks occurring and possible fires or explosions resulting.</p> <p>The amount of charge developed when gasolenes are pumped through pipes has been measured, and several factors influencing the magnitude of this charge have been determined. The problem of "tire static" was investigated, and the general order of magnitude of currents generated by trucks or other rubber-tired vehicles in motion, has been established.</p> <p>A series of experiments was made in an attempt to determine the amount of energy needed in a spark, caused by a condenser discharge, to ignite a combustible mixture of gasolene and air. It was found that relatively small amounts of resistance in series with a spark gap may, in certain cases completely eliminate the ability of a spark to ignite gasolene vapors. There is apparently a minimum wattage required to ignite combustible mixtures.</p> <p>All the measurements and analyses indicate that the precautions commonly practiced in the petroleum industry are more than adequate to eliminate all the hazard of fire or explosion due to static electricity.</p> 1942 Thesis NonPeerReviewed application/pdf https://thesis.library.caltech.edu/4716/1/Wouk_v_1942.pdf https://resolver.caltech.edu/CaltechETD:etd-12022004-153844 Wouk, Victor (1942) Static electricity generated during the distribution of gasolene. Dissertation (Ph.D.), California Institute of Technology. doi:10.7907/9HN9-EE76. https://resolver.caltech.edu/CaltechETD:etd-12022004-153844 <https://resolver.caltech.edu/CaltechETD:etd-12022004-153844> https://thesis.library.caltech.edu/4716/
collection NDLTD
format Others
sources NDLTD
description <p>This research project was undertaken to determine the exact hazard represented by static electricity when it is generated during the distribution of gasolene. "Equivalent electrical circuits" have been utilized which, with the knowledge of the magnitude of charge developed under different conditions, enable one to predict the voltages that will be present and the subsequent chances of sparks occurring and possible fires or explosions resulting.</p> <p>The amount of charge developed when gasolenes are pumped through pipes has been measured, and several factors influencing the magnitude of this charge have been determined. The problem of "tire static" was investigated, and the general order of magnitude of currents generated by trucks or other rubber-tired vehicles in motion, has been established.</p> <p>A series of experiments was made in an attempt to determine the amount of energy needed in a spark, caused by a condenser discharge, to ignite a combustible mixture of gasolene and air. It was found that relatively small amounts of resistance in series with a spark gap may, in certain cases completely eliminate the ability of a spark to ignite gasolene vapors. There is apparently a minimum wattage required to ignite combustible mixtures.</p> <p>All the measurements and analyses indicate that the precautions commonly practiced in the petroleum industry are more than adequate to eliminate all the hazard of fire or explosion due to static electricity.</p>
author Wouk, Victor
spellingShingle Wouk, Victor
Static electricity generated during the distribution of gasolene
author_facet Wouk, Victor
author_sort Wouk, Victor
title Static electricity generated during the distribution of gasolene
title_short Static electricity generated during the distribution of gasolene
title_full Static electricity generated during the distribution of gasolene
title_fullStr Static electricity generated during the distribution of gasolene
title_full_unstemmed Static electricity generated during the distribution of gasolene
title_sort static electricity generated during the distribution of gasolene
publishDate 1942
url https://thesis.library.caltech.edu/4716/1/Wouk_v_1942.pdf
Wouk, Victor (1942) Static electricity generated during the distribution of gasolene. Dissertation (Ph.D.), California Institute of Technology. doi:10.7907/9HN9-EE76. https://resolver.caltech.edu/CaltechETD:etd-12022004-153844 <https://resolver.caltech.edu/CaltechETD:etd-12022004-153844>
work_keys_str_mv AT woukvictor staticelectricitygeneratedduringthedistributionofgasolene
_version_ 1719305119670992896