Arc Fault Circuit Interrupter Development for Residential DC Electricity
The following technical report describes the development and testing of an arc fault circuit interrupter (AFCI) for DC circuits operating primarily at 48 volts. We have identified an effective method for determining when arcing is occurring. Our method is primarily based on comparing the frequency s...