A study of the performance of the LED-based monitoring system for Fermi National Accelerator Laboratory experiment E683's main calorimeter detector

In the experiment E683 at Fermi National Accelerator Lab (FNAL) in Batavia, Illinois, a modular, high-energy sampling calorimeter was the basis of the detector system. In order to monitor each of the 528 modules of the calorimeter, an embedded LED was flashed directly into each of the 528 PMT tubes...

Full description

Bibliographic Details
Main Author: Beery, David D.
Other Authors: Thomas, Gerald P.
Format: Others
Published: 2011
Subjects:
Online Access:http://cardinalscholar.bsu.edu/handle/handle/184913
http://liblink.bsu.edu/uhtbin/catkey/935943
id ndltd-BSU-oai-cardinalscholar.bsu.edu-handle-184913
record_format oai_dc
spelling ndltd-BSU-oai-cardinalscholar.bsu.edu-handle-1849132014-07-24T03:33:23ZA study of the performance of the LED-based monitoring system for Fermi National Accelerator Laboratory experiment E683's main calorimeter detectorBeery, David D.Particle acceleratorsCalorimetryCalorimetersIn the experiment E683 at Fermi National Accelerator Lab (FNAL) in Batavia, Illinois, a modular, high-energy sampling calorimeter was the basis of the detector system. In order to monitor each of the 528 modules of the calorimeter, an embedded LED was flashed directly into each of the 528 PMT tubes (which normally pick up the light from the sampling modules of the calorimeter) and their responses were recorded. The purpose of this investigation was to observe, study, and possibly make corrections for any fluctuations in the PMT response to the LED signals. Also, as a check, the PMT data was analyzed to see if any LED fluctuations were correlated with any fluctuations in the calorimeter module data coming from particles produced when targets were exposed to accelerator beam particles. These studies were done using a VAXstation model 4000/60, and the database and graphics components (called 'N-tuples' and `PAW' respectively) of a High Energy Physics math package called 'CERNLIB'. By putting the analyzed data into n-tuple files, many different modelings of the same data could be checked more efficiently. The study found that the LED system was useful for detecting and correcting for signal degradation due to calamp failure and these corrections were put in the E683 analysis package. It was also found that long term LED response signal fluctuations were not completely explained, but that there was no correlation with beam induced calorimeter response signal fluctuations.Department of Physics and AstronomyThomas, Gerald P.2011-06-03T19:36:38Z2011-06-03T19:36:38Z19941994vi, 113 leaves : ill. ; 28 cm.LD2489.Z78 1994 .B44http://cardinalscholar.bsu.edu/handle/handle/184913http://liblink.bsu.edu/uhtbin/catkey/935943Virtual Press
collection NDLTD
format Others
sources NDLTD
topic Particle accelerators
Calorimetry
Calorimeters
spellingShingle Particle accelerators
Calorimetry
Calorimeters
Beery, David D.
A study of the performance of the LED-based monitoring system for Fermi National Accelerator Laboratory experiment E683's main calorimeter detector
description In the experiment E683 at Fermi National Accelerator Lab (FNAL) in Batavia, Illinois, a modular, high-energy sampling calorimeter was the basis of the detector system. In order to monitor each of the 528 modules of the calorimeter, an embedded LED was flashed directly into each of the 528 PMT tubes (which normally pick up the light from the sampling modules of the calorimeter) and their responses were recorded. The purpose of this investigation was to observe, study, and possibly make corrections for any fluctuations in the PMT response to the LED signals. Also, as a check, the PMT data was analyzed to see if any LED fluctuations were correlated with any fluctuations in the calorimeter module data coming from particles produced when targets were exposed to accelerator beam particles. These studies were done using a VAXstation model 4000/60, and the database and graphics components (called 'N-tuples' and `PAW' respectively) of a High Energy Physics math package called 'CERNLIB'. By putting the analyzed data into n-tuple files, many different modelings of the same data could be checked more efficiently. The study found that the LED system was useful for detecting and correcting for signal degradation due to calamp failure and these corrections were put in the E683 analysis package. It was also found that long term LED response signal fluctuations were not completely explained, but that there was no correlation with beam induced calorimeter response signal fluctuations. === Department of Physics and Astronomy
author2 Thomas, Gerald P.
author_facet Thomas, Gerald P.
Beery, David D.
author Beery, David D.
author_sort Beery, David D.
title A study of the performance of the LED-based monitoring system for Fermi National Accelerator Laboratory experiment E683's main calorimeter detector
title_short A study of the performance of the LED-based monitoring system for Fermi National Accelerator Laboratory experiment E683's main calorimeter detector
title_full A study of the performance of the LED-based monitoring system for Fermi National Accelerator Laboratory experiment E683's main calorimeter detector
title_fullStr A study of the performance of the LED-based monitoring system for Fermi National Accelerator Laboratory experiment E683's main calorimeter detector
title_full_unstemmed A study of the performance of the LED-based monitoring system for Fermi National Accelerator Laboratory experiment E683's main calorimeter detector
title_sort study of the performance of the led-based monitoring system for fermi national accelerator laboratory experiment e683's main calorimeter detector
publishDate 2011
url http://cardinalscholar.bsu.edu/handle/handle/184913
http://liblink.bsu.edu/uhtbin/catkey/935943
work_keys_str_mv AT beerydavidd astudyoftheperformanceoftheledbasedmonitoringsystemforferminationalacceleratorlaboratoryexperimente683smaincalorimeterdetector
AT beerydavidd studyoftheperformanceoftheledbasedmonitoringsystemforferminationalacceleratorlaboratoryexperimente683smaincalorimeterdetector
_version_ 1716708972739690496