An investigation of selected factors affecting feedback in high gain hearing aid fittings

The purpose of this investigation was to compare three typical modes of fitting hearing aids with respect to the amount of maximum gain which could be obtained before the onset of acoustic feedback. A group of 15 children and a group of 15 adults were used. Each subject was fitted with: (1) a regula...

Full description

Bibliographic Details
Main Author: Hoover, Hal N.
Other Authors: Hemeyer, Thomas F.
Format: Others
Published: 2011
Subjects:
Online Access:http://cardinalscholar.bsu.edu/handle/handle/181749
http://liblink.bsu.edu/uhtbin/catkey/280179
id ndltd-BSU-oai-cardinalscholar.bsu.edu-handle-181749
record_format oai_dc
spelling ndltd-BSU-oai-cardinalscholar.bsu.edu-handle-1817492014-08-01T03:31:52ZAn investigation of selected factors affecting feedback in high gain hearing aid fittingsHoover, Hal N.Hearing aids.The purpose of this investigation was to compare three typical modes of fitting hearing aids with respect to the amount of maximum gain which could be obtained before the onset of acoustic feedback. A group of 15 children and a group of 15 adults were used. Each subject was fitted with: (1) a regular ear level hearing aid, (2) a body hearing aid in the conventional mid-torso position, (3) a body hearing aid worn high and to one side of the torso, as is commonly done in binaural body hearing aid fittings. The hearing aid volume controls were increased to a point just prior to the onset of feedback. Once this procedure had been completed for all three hearing aid fittings the high frequency average gain was measured on Bruel and Kjaer equipment.The results indicated that there was no significant difference between the gain values for the two groups, adult versus children. There was, however, a significant difference between the gain values of the three test positions. The mid-torso position achieved the highest gain, the shoulder position was the next highest, and the ear level position achieved the least gain. There was a significant interaction effect between groups (adult, children) and placement (mid-torso, shoulder, ear level).Hemeyer, Thomas F.2011-06-03T19:32:13Z2011-06-03T19:32:13Z1978197830 leaves ; 28 cm.LD2489.Z72 1978 .H66http://cardinalscholar.bsu.edu/handle/handle/181749http://liblink.bsu.edu/uhtbin/catkey/280179Virtual Press
collection NDLTD
format Others
sources NDLTD
topic Hearing aids.
spellingShingle Hearing aids.
Hoover, Hal N.
An investigation of selected factors affecting feedback in high gain hearing aid fittings
description The purpose of this investigation was to compare three typical modes of fitting hearing aids with respect to the amount of maximum gain which could be obtained before the onset of acoustic feedback. A group of 15 children and a group of 15 adults were used. Each subject was fitted with: (1) a regular ear level hearing aid, (2) a body hearing aid in the conventional mid-torso position, (3) a body hearing aid worn high and to one side of the torso, as is commonly done in binaural body hearing aid fittings. The hearing aid volume controls were increased to a point just prior to the onset of feedback. Once this procedure had been completed for all three hearing aid fittings the high frequency average gain was measured on Bruel and Kjaer equipment.The results indicated that there was no significant difference between the gain values for the two groups, adult versus children. There was, however, a significant difference between the gain values of the three test positions. The mid-torso position achieved the highest gain, the shoulder position was the next highest, and the ear level position achieved the least gain. There was a significant interaction effect between groups (adult, children) and placement (mid-torso, shoulder, ear level).
author2 Hemeyer, Thomas F.
author_facet Hemeyer, Thomas F.
Hoover, Hal N.
author Hoover, Hal N.
author_sort Hoover, Hal N.
title An investigation of selected factors affecting feedback in high gain hearing aid fittings
title_short An investigation of selected factors affecting feedback in high gain hearing aid fittings
title_full An investigation of selected factors affecting feedback in high gain hearing aid fittings
title_fullStr An investigation of selected factors affecting feedback in high gain hearing aid fittings
title_full_unstemmed An investigation of selected factors affecting feedback in high gain hearing aid fittings
title_sort investigation of selected factors affecting feedback in high gain hearing aid fittings
publishDate 2011
url http://cardinalscholar.bsu.edu/handle/handle/181749
http://liblink.bsu.edu/uhtbin/catkey/280179
work_keys_str_mv AT hooverhaln aninvestigationofselectedfactorsaffectingfeedbackinhighgainhearingaidfittings
AT hooverhaln investigationofselectedfactorsaffectingfeedbackinhighgainhearingaidfittings
_version_ 1716709513016377344