Measurement of atomic lifetimes in Neon I and Argon I using pulsed rf

Atomic lifetimes of selected levels in Neon I and Argon I were measured using a method of delayed coincidence. Pulsed rf was used to excite a discharge tube containing the neon and argon gas. The radiation emitted from the excited atoms of the gas was passed through a monochromator so only the desir...

Full description

Bibliographic Details
Main Author: Tews, Daniel L.
Other Authors: Hults, Malcom E.
Format: Others
Published: 2011
Subjects:
Online Access:http://cardinalscholar.bsu.edu/handle/handle/180712
http://liblink.bsu.edu/uhtbin/catkey/417030
id ndltd-BSU-oai-cardinalscholar.bsu.edu-handle-180712
record_format oai_dc
spelling ndltd-BSU-oai-cardinalscholar.bsu.edu-handle-1807122014-07-24T03:33:10ZMeasurement of atomic lifetimes in Neon I and Argon I using pulsed rfTews, Daniel L.Neon -- Isotopes -- Decay.Argon -- Isotopes -- Spectra.Exciton theory.Atomic lifetimes of selected levels in Neon I and Argon I were measured using a method of delayed coincidence. Pulsed rf was used to excite a discharge tube containing the neon and argon gas. The radiation emitted from the excited atoms of the gas was passed through a monochromator so only the desired wavelength would be observed. Each time an excitation pulse ended, the decay of light intensity was detected by a photomultiplier tube. By measuring the decay time of the light intensity using the delayed coincidence technique, the average lifetime of the desired level was determined. The values of lifetimes determined in this study were found to contain considerable error. Several factors contributing to these errors were thought to be the shape of the rf pulses and an effort known as cascading which was caused by the use of rf for excitation of the gas.Hults, Malcom E.2011-06-03T19:31:02Z2011-06-03T19:31:02Z19731973v, 68 leaves : ill. ; 28 cm.LD2489.Z78 1973 .T49http://cardinalscholar.bsu.edu/handle/handle/180712http://liblink.bsu.edu/uhtbin/catkey/417030Virtual Press
collection NDLTD
format Others
sources NDLTD
topic Neon -- Isotopes -- Decay.
Argon -- Isotopes -- Spectra.
Exciton theory.
spellingShingle Neon -- Isotopes -- Decay.
Argon -- Isotopes -- Spectra.
Exciton theory.
Tews, Daniel L.
Measurement of atomic lifetimes in Neon I and Argon I using pulsed rf
description Atomic lifetimes of selected levels in Neon I and Argon I were measured using a method of delayed coincidence. Pulsed rf was used to excite a discharge tube containing the neon and argon gas. The radiation emitted from the excited atoms of the gas was passed through a monochromator so only the desired wavelength would be observed. Each time an excitation pulse ended, the decay of light intensity was detected by a photomultiplier tube. By measuring the decay time of the light intensity using the delayed coincidence technique, the average lifetime of the desired level was determined. The values of lifetimes determined in this study were found to contain considerable error. Several factors contributing to these errors were thought to be the shape of the rf pulses and an effort known as cascading which was caused by the use of rf for excitation of the gas.
author2 Hults, Malcom E.
author_facet Hults, Malcom E.
Tews, Daniel L.
author Tews, Daniel L.
author_sort Tews, Daniel L.
title Measurement of atomic lifetimes in Neon I and Argon I using pulsed rf
title_short Measurement of atomic lifetimes in Neon I and Argon I using pulsed rf
title_full Measurement of atomic lifetimes in Neon I and Argon I using pulsed rf
title_fullStr Measurement of atomic lifetimes in Neon I and Argon I using pulsed rf
title_full_unstemmed Measurement of atomic lifetimes in Neon I and Argon I using pulsed rf
title_sort measurement of atomic lifetimes in neon i and argon i using pulsed rf
publishDate 2011
url http://cardinalscholar.bsu.edu/handle/handle/180712
http://liblink.bsu.edu/uhtbin/catkey/417030
work_keys_str_mv AT tewsdaniell measurementofatomiclifetimesinneoniandargoniusingpulsedrf
_version_ 1716708899367682048