Concrete-Filled Steel Tube Columns-Tests Compared with Eurocode 4

This paper summarises the data from 1819 tests on concrete-filled steel tube columns and compares their failure load with the prediction of Eurocode 4. The full data is given on the website http://web.ukonline.co.uk/asccs2 . The comparison with Eurocode 4 is discussed and shows that Eurocode 4 can b...

Full description

Bibliographic Details
Main Authors: Goode, C.D., Lam, Dennis
Language:en
Published: 2014
Subjects:
Online Access:http://hdl.handle.net/10454/5921
Description
Summary:This paper summarises the data from 1819 tests on concrete-filled steel tube columns and compares their failure load with the prediction of Eurocode 4. The full data is given on the website http://web.ukonline.co.uk/asccs2 . The comparison with Eurocode 4 is discussed and shows that Eurocode 4 can be used with confidence and generally gives good agreement with test results, the average Test/EC4 ratio for all tests being 1.11. The Eurocode 4 limitations on concrete strength could be safely extended to concrete with a cylinder strength of 75 N/mm2 for circular sections and 60 N/mm2 for rectangular sections.