Structure Pharmaceutics Based on Synchrotron Radiation X-Ray Micro- Computed Tomography: From Characterization to Evaluation and Innovation of Pharmaceutical Structures

Drug delivery systems (DDS) are essentially pharmaceutical products for human therapy, typically involving a mixture of active ingredients and excipients. Based upon quantitative characterization of structure, the thesis introduces the concept of classifying the architecture of DDS into four leve...

Full description

Bibliographic Details
Main Author: Yin, Xianzhen
Other Authors: York, Peter
Language:en
Published: University of Bradford 2019
Subjects:
Online Access:http://hdl.handle.net/10454/17378
id ndltd-BRADFORD-oai-bradscholars.brad.ac.uk-10454-17378
record_format oai_dc
spelling ndltd-BRADFORD-oai-bradscholars.brad.ac.uk-10454-173782019-10-31T03:08:53Z Structure Pharmaceutics Based on Synchrotron Radiation X-Ray Micro- Computed Tomography: From Characterization to Evaluation and Innovation of Pharmaceutical Structures Yin, Xianzhen York, Peter Shao, Qun Zhang, Jiwen Structure Synchroton radiation micro-computed tomography Three dimension Fractal dimension Quantitative characterisation Solid dosage form Pharmaceutics Drug delivery systems (DDS) are essentially pharmaceutical products for human therapy, typically involving a mixture of active ingredients and excipients. Based upon quantitative characterization of structure, the thesis introduces the concept of classifying the architecture of DDS into four levels by their spatial scale and the life time period. The primary level is recognised as the static structure of the whole dosage form with a size from μm to cm with the final structure generated by formulation design. The secondary level categorises the structures of particles or sub-units to form a DDS with sizes from nm to mm as key units in processing such as mixing, grinding, granulation and packing; The tertiary level represents the dynamic structures of DDS during the drug release phase in vitro or in vivo incorporating the structure size range from nm to mm, which undergo changes during dissolution, swelling, erosion or diffusion. The spatial scale for the quaternary level is defined as the meso or micro scale architecture of active and non-active molecules within a DDS with sizes from Å to μm for the molecular structure of drug and excipients. Methods combining X-ray tomography, image processing, and 3D reconstructions have been devised and evaluated to study systematically pharmaceutical structures and correlate them with drug release kinetics of DDS. Based on the quantitative structural information of pharmaceutical intermediates and dosage forms, it is possible now to correlate structures with production processing, behaviour and function, and the static and dynamic structures of DDS with the release kinetics. Thus, a structure-guided methodology has been established for the research of DDS. Chinese Academy of Sciences 2019-10-29T08:47:14Z 2019-10-29T08:47:14Z 2016 Thesis doctoral PhD http://hdl.handle.net/10454/17378 en <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/"><img alt="Creative Commons License" style="border-width:0" src="http://i.creativecommons.org/l/by-nc-nd/3.0/88x31.png" /></a><br />The University of Bradford theses are licenced under a <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/">Creative Commons Licence</a>. University of Bradford University of Bradford Faculty of Life Sciences
collection NDLTD
language en
sources NDLTD
topic Structure
Synchroton radiation micro-computed tomography
Three dimension
Fractal dimension
Quantitative characterisation
Solid dosage form
Pharmaceutics
spellingShingle Structure
Synchroton radiation micro-computed tomography
Three dimension
Fractal dimension
Quantitative characterisation
Solid dosage form
Pharmaceutics
Yin, Xianzhen
Structure Pharmaceutics Based on Synchrotron Radiation X-Ray Micro- Computed Tomography: From Characterization to Evaluation and Innovation of Pharmaceutical Structures
description Drug delivery systems (DDS) are essentially pharmaceutical products for human therapy, typically involving a mixture of active ingredients and excipients. Based upon quantitative characterization of structure, the thesis introduces the concept of classifying the architecture of DDS into four levels by their spatial scale and the life time period. The primary level is recognised as the static structure of the whole dosage form with a size from μm to cm with the final structure generated by formulation design. The secondary level categorises the structures of particles or sub-units to form a DDS with sizes from nm to mm as key units in processing such as mixing, grinding, granulation and packing; The tertiary level represents the dynamic structures of DDS during the drug release phase in vitro or in vivo incorporating the structure size range from nm to mm, which undergo changes during dissolution, swelling, erosion or diffusion. The spatial scale for the quaternary level is defined as the meso or micro scale architecture of active and non-active molecules within a DDS with sizes from Å to μm for the molecular structure of drug and excipients. Methods combining X-ray tomography, image processing, and 3D reconstructions have been devised and evaluated to study systematically pharmaceutical structures and correlate them with drug release kinetics of DDS. Based on the quantitative structural information of pharmaceutical intermediates and dosage forms, it is possible now to correlate structures with production processing, behaviour and function, and the static and dynamic structures of DDS with the release kinetics. Thus, a structure-guided methodology has been established for the research of DDS. === Chinese Academy of Sciences
author2 York, Peter
author_facet York, Peter
Yin, Xianzhen
author Yin, Xianzhen
author_sort Yin, Xianzhen
title Structure Pharmaceutics Based on Synchrotron Radiation X-Ray Micro- Computed Tomography: From Characterization to Evaluation and Innovation of Pharmaceutical Structures
title_short Structure Pharmaceutics Based on Synchrotron Radiation X-Ray Micro- Computed Tomography: From Characterization to Evaluation and Innovation of Pharmaceutical Structures
title_full Structure Pharmaceutics Based on Synchrotron Radiation X-Ray Micro- Computed Tomography: From Characterization to Evaluation and Innovation of Pharmaceutical Structures
title_fullStr Structure Pharmaceutics Based on Synchrotron Radiation X-Ray Micro- Computed Tomography: From Characterization to Evaluation and Innovation of Pharmaceutical Structures
title_full_unstemmed Structure Pharmaceutics Based on Synchrotron Radiation X-Ray Micro- Computed Tomography: From Characterization to Evaluation and Innovation of Pharmaceutical Structures
title_sort structure pharmaceutics based on synchrotron radiation x-ray micro- computed tomography: from characterization to evaluation and innovation of pharmaceutical structures
publisher University of Bradford
publishDate 2019
url http://hdl.handle.net/10454/17378
work_keys_str_mv AT yinxianzhen structurepharmaceuticsbasedonsynchrotronradiationxraymicrocomputedtomographyfromcharacterizationtoevaluationandinnovationofpharmaceuticalstructures
_version_ 1719283423742263296