Sound Absorption and Sound Power Measurements in Reverberation Chambers Using Energy Density Methods

Measurements in a reverberation chamber use spatially averaged squared pressure to calculate sound absorption, sound power, and other sound measurements. While a reverberation chamber provides an approximation of a diffuse sound field, variations in the measurements introduce uncertainty in measurem...

Full description

Bibliographic Details
Main Author: Nutter, David B.
Format: Others
Published: BYU ScholarsArchive 2006
Subjects:
ED
Online Access:https://scholarsarchive.byu.edu/etd/771
https://scholarsarchive.byu.edu/cgi/viewcontent.cgi?article=1770&context=etd
Description
Summary:Measurements in a reverberation chamber use spatially averaged squared pressure to calculate sound absorption, sound power, and other sound measurements. While a reverberation chamber provides an approximation of a diffuse sound field, variations in the measurements introduce uncertainty in measurement results. Room qualification procedures require a sufficient number of source-receiver locations to obtain suitable measurements. The total acoustic energy density provides greater spatial uniformity than squared pressure, which requires fewer source-receiver positions to produce similar or better accuracy in measurement results. This paper explores the possibility of using energy density in place of squared pressure, using methods outlined in current ISO standards, by describing several experimental and analytical results.