Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer

The inductively coupled plasma mass spectrometer (ICP-MS) is the instrument of choice for trace and ultra-trace elemental analysis. However, the ICP-MS suffers from matrix effects. Matrix effects occur when instrument response varies as the composition of the sample matrix is changed. Matrix effects...

Full description

Bibliographic Details
Main Author: Macedone, Jeffrey Harris
Format: Others
Published: BYU ScholarsArchive 2005
Subjects:
Online Access:https://scholarsarchive.byu.edu/etd/274
https://scholarsarchive.byu.edu/cgi/viewcontent.cgi?article=1273&context=etd
id ndltd-BGMYU2-oai-scholarsarchive.byu.edu-etd-1273
record_format oai_dc
spelling ndltd-BGMYU2-oai-scholarsarchive.byu.edu-etd-12732019-05-16T03:33:23Z Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer Macedone, Jeffrey Harris The inductively coupled plasma mass spectrometer (ICP-MS) is the instrument of choice for trace and ultra-trace elemental analysis. However, the ICP-MS suffers from matrix effects. Matrix effects occur when instrument response varies as the composition of the sample matrix is changed. Matrix effects, or non-spectroscopic interferences, limit the accuracy of routine analysis. Identification of the sources of matrix effects provide a basis for reducing or eliminating them. As inaccuracies in the ICP-MS are more severe than those in the ICP atomic emission spectrometer, the problem may be due, at least in part, to the vacuum interface used to couple the plasma source and mass spectrometer. The research herein is a study of matrix effect sources in the first stage of the vacuum interface. This study utilized laser-induced fluorescence of atomic species to identify factors affecting analyte transport through the sampling orifice of the vacuum interface. Several non-idealities in the performance of the interface were found. (1) Operating conditions and sample compositions can negatively affect the efficiency with which ions are extracted through the vacuum interface coupling the plasma source to the mass spectrometer. (2) The sampling cone itself was found to suppress and narrow ion distributions in the plasma. (3) Changes in the degree of ionization were identified in the first vacuum stage. The evidence of recombination and state-changing collisions was observed in the first vacuum stage at lower power settings. Matrix effects occur in the first vacuum stage, the first step of the ion extraction process. This work shows that changes in ion transport through the first vacuum stage of the vacuum interface of an ICP-MS affect the overall performance of the instrument. 2005-03-28T08:00:00Z text application/pdf https://scholarsarchive.byu.edu/etd/274 https://scholarsarchive.byu.edu/cgi/viewcontent.cgi?article=1273&context=etd http://lib.byu.edu/about/copyright/ All Theses and Dissertations BYU ScholarsArchive inductively coupled plasma mass spectrometry ICP-MS ion transmission atomic fluorescence matrix effects Biochemistry Chemistry
collection NDLTD
format Others
sources NDLTD
topic inductively coupled plasma mass spectrometry
ICP-MS
ion transmission
atomic fluorescence
matrix effects
Biochemistry
Chemistry
spellingShingle inductively coupled plasma mass spectrometry
ICP-MS
ion transmission
atomic fluorescence
matrix effects
Biochemistry
Chemistry
Macedone, Jeffrey Harris
Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer
description The inductively coupled plasma mass spectrometer (ICP-MS) is the instrument of choice for trace and ultra-trace elemental analysis. However, the ICP-MS suffers from matrix effects. Matrix effects occur when instrument response varies as the composition of the sample matrix is changed. Matrix effects, or non-spectroscopic interferences, limit the accuracy of routine analysis. Identification of the sources of matrix effects provide a basis for reducing or eliminating them. As inaccuracies in the ICP-MS are more severe than those in the ICP atomic emission spectrometer, the problem may be due, at least in part, to the vacuum interface used to couple the plasma source and mass spectrometer. The research herein is a study of matrix effect sources in the first stage of the vacuum interface. This study utilized laser-induced fluorescence of atomic species to identify factors affecting analyte transport through the sampling orifice of the vacuum interface. Several non-idealities in the performance of the interface were found. (1) Operating conditions and sample compositions can negatively affect the efficiency with which ions are extracted through the vacuum interface coupling the plasma source to the mass spectrometer. (2) The sampling cone itself was found to suppress and narrow ion distributions in the plasma. (3) Changes in the degree of ionization were identified in the first vacuum stage. The evidence of recombination and state-changing collisions was observed in the first vacuum stage at lower power settings. Matrix effects occur in the first vacuum stage, the first step of the ion extraction process. This work shows that changes in ion transport through the first vacuum stage of the vacuum interface of an ICP-MS affect the overall performance of the instrument.
author Macedone, Jeffrey Harris
author_facet Macedone, Jeffrey Harris
author_sort Macedone, Jeffrey Harris
title Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer
title_short Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer
title_full Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer
title_fullStr Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer
title_full_unstemmed Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer
title_sort ion transmission in the first vacuum stage of an inductively coupled plasma mass spectrometer
publisher BYU ScholarsArchive
publishDate 2005
url https://scholarsarchive.byu.edu/etd/274
https://scholarsarchive.byu.edu/cgi/viewcontent.cgi?article=1273&context=etd
work_keys_str_mv AT macedonejeffreyharris iontransmissioninthefirstvacuumstageofaninductivelycoupledplasmamassspectrometer
_version_ 1719186671454388224