|
|
|
|
LEADER |
02899 am a22002773u 4500 |
001 |
90993 |
042 |
|
|
|a dc
|
100 |
1 |
0 |
|a Kashif, Faisal Mahmood
|e author
|
100 |
1 |
0 |
|a Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
|e contributor
|
100 |
1 |
0 |
|a Massachusetts Institute of Technology. Research Laboratory of Electronics
|e contributor
|
100 |
1 |
0 |
|a Kashif, Faisal Mahmood
|e contributor
|
100 |
1 |
0 |
|a Verghese, George C.
|e contributor
|
100 |
1 |
0 |
|a Heldt, Thomas
|e contributor
|
700 |
1 |
0 |
|a Verghese, George C.
|e author
|
700 |
1 |
0 |
|a Heldt, Thomas
|e author
|
700 |
1 |
0 |
|a Novak, Vera
|e author
|
700 |
1 |
0 |
|a Czosnyka, Marek
|e author
|
245 |
0 |
0 |
|a Model-Based Noninvasive Estimation of Intracranial Pressure from Cerebral Blood Flow Velocity and Arterial Pressure
|
260 |
|
|
|b American Association for the Advancement of Science (AAAS),
|c 2014-10-20T17:14:51Z.
|
856 |
|
|
|z Get fulltext
|u http://hdl.handle.net/1721.1/90993
|
520 |
|
|
|a Intracranial pressure (ICP) is affected in many neurological conditions. Clinical measurement of pressure on the brain currently requires placing a probe in the cerebrospinal fluid compartment, the brain tissue, or other intracranial space. This invasiveness limits the measurement to critically ill patients. Because ICP is also clinically important in conditions ranging from brain tumors and hydrocephalus to concussions, noninvasive determination of ICP would be desirable. Our model-based approach to continuous estimation and tracking of ICP uses routinely obtainable time-synchronized, noninvasive (or minimally invasive) measurements of peripheral arterial blood pressure and blood flow velocity in the middle cerebral artery (MCA), both at intra-heartbeat resolution. A physiological model of cerebrovascular dynamics provides mathematical constraints that relate the measured waveforms to ICP. Our algorithm produces patient-specific ICP estimates with no calibration or training. Using 35 hours of data from 37 patients with traumatic brain injury, we generated ICP estimates on 2665 nonoverlapping 60-beat data windows. Referenced against concurrently recorded invasive parenchymal ICP that varied over 100 millimeters of mercury (mmHg) across all records, our estimates achieved a mean error (bias) of 1.6 mmHg and SD of error (SDE) of 7.6 mmHg. For the 1673 data windows over 22 hours in which blood flow velocity recordings were available from both the left and the right MCA, averaging the resulting bilateral ICP estimates reduced the bias to 1.5 mmHg and SDE to 5.9 mmHg. This accuracy is already comparable to that of some invasive ICP measurement methods in current clinical use.
|
520 |
|
|
|a National Institutes of Health (U.S.) (R01 EB001659)
|
520 |
|
|
|a CIMIT: Center for Integration of Medicine and Innovative Technology
|
546 |
|
|
|a en_US
|
655 |
7 |
|
|a Article
|
773 |
|
|
|t Science Translational Medicine
|