Comparing the quantification of Forster resonance energy transfer measurement accuracies based on intensity, spectral, and lifetime imaging

The measurement of Förster resonance energy transfer (FRET) in microscopes can be realized by different imaging modalities. In the present work, reference FRET constructs are developed to allow the comparison of FRET microscopy measurements using intensity, spectral, and lifetime imaging. Complimen...

Full description

Bibliographic Details
Main Authors: Pelet, Serge (Contributor), Previte, Michael J. R. (Contributor), So, Peter T. C. (Contributor)
Other Authors: Massachusetts Institute of Technology. Department of Biological Engineering (Contributor), Massachusetts Institute of Technology. Department of Mechanical Engineering (Contributor)
Format: Article
Language:English
Published: SPIE, 2014-06-05T15:19:12Z.
Subjects:
Online Access:Get fulltext
LEADER 02234 am a22002413u 4500
001 87648
042 |a dc 
100 1 0 |a Pelet, Serge  |e author 
100 1 0 |a Massachusetts Institute of Technology. Department of Biological Engineering  |e contributor 
100 1 0 |a Massachusetts Institute of Technology. Department of Mechanical Engineering  |e contributor 
100 1 0 |a Pelet, Serge  |e contributor 
100 1 0 |a Previte, Michael J. R.  |e contributor 
100 1 0 |a So, Peter T. C.  |e contributor 
700 1 0 |a Previte, Michael J. R.  |e author 
700 1 0 |a So, Peter T. C.  |e author 
245 0 0 |a Comparing the quantification of Forster resonance energy transfer measurement accuracies based on intensity, spectral, and lifetime imaging 
260 |b SPIE,   |c 2014-06-05T15:19:12Z. 
856 |z Get fulltext  |u http://hdl.handle.net/1721.1/87648 
520 |a The measurement of Förster resonance energy transfer (FRET) in microscopes can be realized by different imaging modalities. In the present work, reference FRET constructs are developed to allow the comparison of FRET microscopy measurements using intensity, spectral, and lifetime imaging. Complimentary DNA strands are respectively labeled with Oregon Green 488 (OG488) or tetramethylrhodamine (TMR). The OG488 dye is fixed at the 5' end of one strand, and the TMR label position is allowed to vary along the complimentary strand. Since OG488 and TMR are FRET pairs, the FRET efficiency can be determined theoretically from the distance separating the two dyes of the double-stranded DNA molecules. Microscopic images are formed by imaging microcapillaries containing various mixtures of oligonucleotides labeled with the FRET fluorophore pair, only the donor, or only acceptor. Traditional two-channel intensity measurements are compared with spectrally resolved imaging and fluorescence lifetime imaging by calculating a FRET index. The latter proves to be the best method to quantify FRET efficiency in the image. More importantly, the intensity fraction of molecules undergoing FRET can be quantitatively measured in each pixel of the image. 
520 |a National Institutes of Health (U.S.) (Grant NIHPOIHL64858) 
546 |a en_US 
655 7 |a Article 
773 |t Journal of Biomedical Optics