A Technique for Performing Electrical Impedance Myography in the Mouse Hind Limb: Data in Normal and ALS SOD1 G93A Animals

Objective: To test a method for performing electrical impedance myography (EIM) in the mouse hind limb for the assessment of disease status in neuromuscular disease models. Methods: An impedance measuring device consisting of a frame with electrodes embedded within an acrylic head was developed. The...

Full description

Bibliographic Details
Main Authors: Staats, Wayne Lawrence (Contributor), Li, Jia (Author), Spieker, Andrew (Author), Sung, Minhee (Author), Rutkove, Seward B. (Author)
Other Authors: Massachusetts Institute of Technology. Department of Mechanical Engineering (Contributor)
Format: Article
Language:English
Published: Public Library of Science, 2013-01-23T17:48:12Z.
Subjects:
Online Access:Get fulltext
LEADER 02008 am a22002173u 4500
001 76362
042 |a dc 
100 1 0 |a Staats, Wayne Lawrence  |e author 
100 1 0 |a Massachusetts Institute of Technology. Department of Mechanical Engineering  |e contributor 
100 1 0 |a Staats, Wayne Lawrence  |e contributor 
700 1 0 |a Li, Jia  |e author 
700 1 0 |a Spieker, Andrew  |e author 
700 1 0 |a Sung, Minhee  |e author 
700 1 0 |a Rutkove, Seward B.  |e author 
245 0 0 |a A Technique for Performing Electrical Impedance Myography in the Mouse Hind Limb: Data in Normal and ALS SOD1 G93A Animals 
260 |b Public Library of Science,   |c 2013-01-23T17:48:12Z. 
856 |z Get fulltext  |u http://hdl.handle.net/1721.1/76362 
520 |a Objective: To test a method for performing electrical impedance myography (EIM) in the mouse hind limb for the assessment of disease status in neuromuscular disease models. Methods: An impedance measuring device consisting of a frame with electrodes embedded within an acrylic head was developed. The head was rotatable such that data longitudinal and transverse to the major muscle fiber direction could be obtained. EIM measurements were made with this device on 16 healthy mice and 14 amyotrophic lateral sclerosis (ALS) animals. Repeatability was assessed in both groups. Results: The technique was easy to perform and provided good repeatability in both healthy and ALS animals, with intra-session repeatability (mean ± SEM) of 5% ±1% and 12% ±2%, respectively. Significant differences between healthy and ALS animals were also identified (e.g., longitudinal mean 50 kHz phase was 18±0.6° for the healthy animals and 14±1.0° for the ALS animals, p = 0.0025). Conclusions: With this simple device, the EIM data obtained is highly repeatable and can differentiate healthy from ALS animals. Significance: EIM can now be applied to mouse models of neuromuscular disease to assess disease status and the effects of therapy. 
546 |a en_US 
655 7 |a Article 
773 |t PLoS ONE