Quantification of thrombus formation in malapposed coronary stents deployed in vitro through imaging analysis

Stent thrombosis is a major complication of coronary stent and scaffold intervention. While often unanticipated and lethal, its incidence is low making mechanistic examination difficult through clinical investigation alone. Thus, throughout the technological advancement of these devices, experimenta...

Full description

Bibliographic Details
Main Authors: Brown, Jonathan (Author), O'Brien, Caroline C. (Author), Lopes Jr, Augusto Celso de Araujo (Author), Kolandaivelu, Kumaran (Author), Edelman, Elazer R (Author)
Other Authors: Massachusetts Institute of Technology. Institute for Medical Engineering & Science (Contributor)
Format: Article
Language:English
Published: Elsevier BV, 2020-07-27T19:08:48Z.
Subjects:
Online Access:Get fulltext
LEADER 02709 am a22002173u 4500
001 126400
042 |a dc 
100 1 0 |a Brown, Jonathan  |e author 
100 1 0 |a Massachusetts Institute of Technology. Institute for Medical Engineering & Science  |e contributor 
700 1 0 |a O'Brien, Caroline C.  |e author 
700 1 0 |a Lopes Jr, Augusto Celso de Araujo  |e author 
700 1 0 |a Kolandaivelu, Kumaran  |e author 
700 1 0 |a Edelman, Elazer R  |e author 
245 0 0 |a Quantification of thrombus formation in malapposed coronary stents deployed in vitro through imaging analysis 
260 |b Elsevier BV,   |c 2020-07-27T19:08:48Z. 
856 |z Get fulltext  |u https://hdl.handle.net/1721.1/126400 
520 |a Stent thrombosis is a major complication of coronary stent and scaffold intervention. While often unanticipated and lethal, its incidence is low making mechanistic examination difficult through clinical investigation alone. Thus, throughout the technological advancement of these devices, experimental models have been indispensable in furthering our understanding of device safety and efficacy. As we refine model systems to gain deeper insight into adverse events, it is equally important that we continue to refine our measurement methods. We used digital signal processing in an established flow loop model to investigate local flow effects due to geometric stent features and ultimately its relationship to thrombus formation. A new metric of clot distribution on each microCT slice termed normalized clot ratio was defined to quantify this distribution. Three under expanded coronary bare-metal stents were run in a flow loop model to induce clotting. Samples were then scanned in a MicroCT machine and digital signal processing methods applied to analyze geometric stent conformation and spatial clot formation. Results indicated that geometric stent features play a significant role in clotting patterns, specifically at a frequency of 0.6225 Hz corresponding to a geometric distance of 1.606 mm. The magnitude-squared coherence between geometric features and clot distribution was greater than 0.4 in all samples. In stents with poor wall apposition, ranging from 0.27 mm to 0.64 mm maximum malapposition (model of real-world heterogeneity), clots were found to have formed in between stent struts rather than directly adjacent to struts. This early work shows how the combination of tools in the areas of image processing and signal analysis can advance the resolution at which we are able to define thrombotic mechanisms in in vitro models, and ultimately, gain further insight into clinical performance. 
520 |a NIH (Grant R01 GM-49039) 
546 |a en 
655 7 |a Article 
773 |t Journal of Biomechanics