Alignment of the CMS silicon tracker during commissioning with cosmic rays

The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray...

Full description

Bibliographic Details
Main Authors: Alver, Burak Han (Author), Bauer, Gerry P (Author), Bendavid, Joshua L. (Author), Busza, Wit (Author), Butz, Erik M. (Author), Cali, Ivan Amos (Author), Chan, M. (Author), D'Enterria, David (Author), Everaerts, Pieter Bruno Bart (Author), Gomez-Ceballos, Guillelmo (Author), Hahn, K. A (Author), Harris, Philip Coleman (Author), Jaditz, Stephen Hunter (Author), Kim, Y. (Author), Klute, Markus (Author), Lee, Y.-J (Author), Li, W. (Author), Loizides, Constantinos (Author), Ma, T. (Author), Miller, M. (Author), Nahn, Steven C. (Author), Paus, Christoph M. E. (Author), Roland, Christof E (Author), Roland, Gunther M (Author), Rudolph, Matthew Scott (Author), Stephans, George S. F. (Author), Sumorok, Konstanty C (Author), Sung, K. (Author), Vaurynovich, Siarhei S. (Author), Wenger, Edward Allen (Author), Wyslouch, Boleslaw (Author), Xie, S. (Author), Yilmaz, Yetkin (Author), Yoon, A. S. (Author), CMS Collaboration (Author)
Other Authors: Massachusetts Institute of Technology. Department of Physics (Contributor), Massachusetts Institute of Technology. Laboratory for Nuclear Science (Contributor), Massachusetts Institute of Technology. Department of Nuclear Science and Engineering (Contributor)
Format: Article
Language:English
Published: IOP Publishing, 2019-07-10T17:32:03Z.
Subjects:
Online Access:Get fulltext
Description
Summary:The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance.