Measurement of wetted area fraction in subcooled pool boiling of water using infrared thermography

The wetted area fraction in subcooled pool boiling of water at atmospheric pressure is measured using the DEPIcT (DEtection of Phase by Infrared Thermography) technique. DEPIcT exploits the contrast in infrared (IR) light emissions between wet and dry areas on the surface of an IR-transparent heater...

Full description

Bibliographic Details
Main Authors: Park, Youngjae (Author), Kim, Hyung Dae (Contributor), Buongiorno, Jacopo (Contributor)
Other Authors: Massachusetts Institute of Technology. Department of Nuclear Science and Engineering (Contributor)
Format: Article
Language:English
Published: Elsevier, 2017-04-11T13:22:28Z.
Subjects:
Online Access:Get fulltext
LEADER 01948 am a22002293u 4500
001 108036
042 |a dc 
100 1 0 |a Park, Youngjae  |e author 
100 1 0 |a Massachusetts Institute of Technology. Department of Nuclear Science and Engineering  |e contributor 
100 1 0 |a Buongiorno, Jacopo  |e contributor 
100 1 0 |a Kim, Hyung Dae  |e contributor 
100 1 0 |a Buongiorno, Jacopo  |e contributor 
700 1 0 |a Kim, Hyung Dae  |e author 
700 1 0 |a Buongiorno, Jacopo  |e author 
245 0 0 |a Measurement of wetted area fraction in subcooled pool boiling of water using infrared thermography 
260 |b Elsevier,   |c 2017-04-11T13:22:28Z. 
856 |z Get fulltext  |u http://hdl.handle.net/1721.1/108036 
520 |a The wetted area fraction in subcooled pool boiling of water at atmospheric pressure is measured using the DEPIcT (DEtection of Phase by Infrared Thermography) technique. DEPIcT exploits the contrast in infrared (IR) light emissions between wet and dry areas on the surface of an IR-transparent heater to visualize the instantaneous distribution of the liquid and gas phases in contact with the heater surface. In this paper time-averaged wetted area fraction data in nucleate boiling are reported as functions of heat flux (from 30% up to 100% of the Critical Heat Flux) and subcooling (ΔTsub = 0, 5, 10, 30 and 50 °C). The results show that the wetted area fraction monotonically decreases with increasing heat flux and increases with increasing subcooling: both trends are expected. The range of time-averaged wetted area fractions is from 90%, at low heat flux and high subcooling, to 50% at high heat flux (right before CHF) and low subcooling. It is also shown that the dry areas are periodically rewetted by liquid sloshing on the surface at any subcooling and heat flux; however, the dry areas expand irreversibly at CHF. 
520 |a MIT Energy Initiative 
546 |a en_US 
655 7 |a Article 
773 |t Nuclear Engineering and Design