Modelling of a 3-phase induction motor under open-phase fault using matlab/simulink

The d-q model of Induction Motors (IMs) has been effectively used as an efficient method to analyze the performance of the induction machines. This study presents a step by step Matlab/Simulink implementation of a star-connected 3-phase IM under open-phase fault (faulty 3-phase IM) using d-q model....

Full description

Bibliographic Details
Main Authors: Jannati, M. (Author), Sutikno, T. (Author)
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science, 2016.
Subjects:
Online Access:Get fulltext
LEADER 01086 am a22001453u 4500
001 71859
042 |a dc 
100 1 0 |a Jannati, M.  |e author 
700 1 0 |a Sutikno, T.  |e author 
245 0 0 |a Modelling of a 3-phase induction motor under open-phase fault using matlab/simulink 
260 |b Institute of Advanced Engineering and Science,   |c 2016. 
856 |z Get fulltext  |u http://eprints.utm.my/id/eprint/71859/1/MohammadJannati2016_Modellingofa3PhaseInductionMotor.pdf 
520 |a The d-q model of Induction Motors (IMs) has been effectively used as an efficient method to analyze the performance of the induction machines. This study presents a step by step Matlab/Simulink implementation of a star-connected 3-phase IM under open-phase fault (faulty 3-phase IM) using d-q model. The presented technique in this paper can be simply implemented in one block and can be made available for control purposes. The simulated results provide to show the behavior of the star-connected 3-phase IM under open-phase fault condition. 
546 |a en 
650 0 4 |a TK Electrical engineering. Electronics Nuclear engineering