The effect of static stretch on elastin degradation in arteries.

Previously we have shown that gradual changes in the structure of elastin during an elastase treatment can lead to important transition stages in the mechanical behavior of arteries. However, in vivo arteries are constantly being loaded due to systolic and diastolic pressures and so understanding th...

Full description

Bibliographic Details
Main Authors: Ming-Jay Chow, Myunghwan Choi, Seok Hyun Yun, Yanhang Zhang
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2013-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC3864902?pdf=render
id doaj-ffeac8b1516c4fc8b7ed32366a92ca82
record_format Article
spelling doaj-ffeac8b1516c4fc8b7ed32366a92ca822020-11-24T22:04:04ZengPublic Library of Science (PLoS)PLoS ONE1932-62032013-01-01812e8195110.1371/journal.pone.0081951The effect of static stretch on elastin degradation in arteries.Ming-Jay ChowMyunghwan ChoiSeok Hyun YunYanhang ZhangPreviously we have shown that gradual changes in the structure of elastin during an elastase treatment can lead to important transition stages in the mechanical behavior of arteries. However, in vivo arteries are constantly being loaded due to systolic and diastolic pressures and so understanding the effects of loading on the enzymatic degradation of elastin in arteries is important. With biaxial tensile testing, we measured the mechanical behavior of porcine thoracic aortas digested with a mild solution of purified elastase (5 U/mL) in the presence of a static stretch. Arterial mechanical properties and biochemical composition were analyzed to assess the effects of mechanical stretch on elastin degradation. As elastin is being removed, the dimensions of the artery increase by more than 20% in both the longitude and circumference directions. Elastin assays indicate a faster rate of degradation when stretch was present during the digestion. A simple exponential decay fitting confirms the time constant for digestion with stretch (0.11 ± 0.04 h(-1)) is almost twice that of digestion without stretch (0.069 ± 0.028 h(-1)). The transition from J-shaped to S-shaped stress vs. strain behavior in the longitudinal direction generally occurs when elastin content is reduced by about 60%. Multiphoton image analysis confirms the removal/fragmentation of elastin and also shows that the collagen fibers are closely intertwined with the elastin lamellae in the medial layer. After removal of elastin, the collagen fibers are no longer constrained and become disordered. Release of amorphous elastin during the fragmentation of the lamellae layers is observed and provides insights into the process of elastin degradation. Overall this study reveals several interesting microstructural changes in the extracellular matrix that could explain the resulting mechanical behavior of arteries with elastin degradation.http://europepmc.org/articles/PMC3864902?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Ming-Jay Chow
Myunghwan Choi
Seok Hyun Yun
Yanhang Zhang
spellingShingle Ming-Jay Chow
Myunghwan Choi
Seok Hyun Yun
Yanhang Zhang
The effect of static stretch on elastin degradation in arteries.
PLoS ONE
author_facet Ming-Jay Chow
Myunghwan Choi
Seok Hyun Yun
Yanhang Zhang
author_sort Ming-Jay Chow
title The effect of static stretch on elastin degradation in arteries.
title_short The effect of static stretch on elastin degradation in arteries.
title_full The effect of static stretch on elastin degradation in arteries.
title_fullStr The effect of static stretch on elastin degradation in arteries.
title_full_unstemmed The effect of static stretch on elastin degradation in arteries.
title_sort effect of static stretch on elastin degradation in arteries.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2013-01-01
description Previously we have shown that gradual changes in the structure of elastin during an elastase treatment can lead to important transition stages in the mechanical behavior of arteries. However, in vivo arteries are constantly being loaded due to systolic and diastolic pressures and so understanding the effects of loading on the enzymatic degradation of elastin in arteries is important. With biaxial tensile testing, we measured the mechanical behavior of porcine thoracic aortas digested with a mild solution of purified elastase (5 U/mL) in the presence of a static stretch. Arterial mechanical properties and biochemical composition were analyzed to assess the effects of mechanical stretch on elastin degradation. As elastin is being removed, the dimensions of the artery increase by more than 20% in both the longitude and circumference directions. Elastin assays indicate a faster rate of degradation when stretch was present during the digestion. A simple exponential decay fitting confirms the time constant for digestion with stretch (0.11 ± 0.04 h(-1)) is almost twice that of digestion without stretch (0.069 ± 0.028 h(-1)). The transition from J-shaped to S-shaped stress vs. strain behavior in the longitudinal direction generally occurs when elastin content is reduced by about 60%. Multiphoton image analysis confirms the removal/fragmentation of elastin and also shows that the collagen fibers are closely intertwined with the elastin lamellae in the medial layer. After removal of elastin, the collagen fibers are no longer constrained and become disordered. Release of amorphous elastin during the fragmentation of the lamellae layers is observed and provides insights into the process of elastin degradation. Overall this study reveals several interesting microstructural changes in the extracellular matrix that could explain the resulting mechanical behavior of arteries with elastin degradation.
url http://europepmc.org/articles/PMC3864902?pdf=render
work_keys_str_mv AT mingjaychow theeffectofstaticstretchonelastindegradationinarteries
AT myunghwanchoi theeffectofstaticstretchonelastindegradationinarteries
AT seokhyunyun theeffectofstaticstretchonelastindegradationinarteries
AT yanhangzhang theeffectofstaticstretchonelastindegradationinarteries
AT mingjaychow effectofstaticstretchonelastindegradationinarteries
AT myunghwanchoi effectofstaticstretchonelastindegradationinarteries
AT seokhyunyun effectofstaticstretchonelastindegradationinarteries
AT yanhangzhang effectofstaticstretchonelastindegradationinarteries
_version_ 1725830740752465920