The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station
A prefabricated pumping station is a new type of pumping station that plays an important role in the construction of sponge cities in developing countries. It solves the problem of urban water-logging and makes great contributions to the sustainable development of water resources. In order to resear...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-02-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/14/4/1039 |
id |
doaj-ffdf3e1539d64aba90f9e77d4f2a0641 |
---|---|
record_format |
Article |
spelling |
doaj-ffdf3e1539d64aba90f9e77d4f2a06412021-02-17T00:04:16ZengMDPI AGEnergies1996-10732021-02-01141039103910.3390/en14041039The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping StationBowen Zhang0Li Cheng1Chunlei Xu2Mo Wang3College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, ChinaCollege of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, ChinaKey water conservancy project management office, Wuxi 214000, ChinaAnhui Branch of Hainan water resources and Hydropower Survey and Design Institute, Hefei 225000, ChinaA prefabricated pumping station is a new type of pumping station that plays an important role in the construction of sponge cities in developing countries. It solves the problem of urban water-logging and makes great contributions to the sustainable development of water resources. In order to research the influence of different installation positions of pumps on the internal hydraulic performance of a prefabricated pumping station, based on ANSYS software, the computational fluid dynamics (CFD) numerical simulation method was used to analyze the internal flow state of the prefabricated pump station. In this research, the optimal geometric parameters of pump installation in a prefabricated pumping station are given. The results show that when the distance between the connecting line of two pumps and the center of the sump is <i>L </i>= 0.2 <i>R</i>, the distance between the two pumps is <i>S </i>= 0.6 <i>R</i>, and the suspension height of the two pumps is <i>H </i>= 0.6 <i>D</i>, the internal flow pattern of the prefabricated pump station is better. (<i>R</i> is the cross-sectional radius of the sump and <i>D</i> is the diameter of the nozzle of the pump horn.) These research results have certain guiding significance for improvement of the hydraulic performance and operation efficiency of prefabricated pump stations. They also provide a theoretical basis for parameter selection for prefabricated pumping stations.https://www.mdpi.com/1996-1073/14/4/1039prefabricated pumping stationhydraulic performancegeometric parameterinstallation positionnumerical simulation |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Bowen Zhang Li Cheng Chunlei Xu Mo Wang |
spellingShingle |
Bowen Zhang Li Cheng Chunlei Xu Mo Wang The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station Energies prefabricated pumping station hydraulic performance geometric parameter installation position numerical simulation |
author_facet |
Bowen Zhang Li Cheng Chunlei Xu Mo Wang |
author_sort |
Bowen Zhang |
title |
The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station |
title_short |
The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station |
title_full |
The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station |
title_fullStr |
The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station |
title_full_unstemmed |
The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station |
title_sort |
influence of geometric parameters of pump installation on the hydraulic performance of a prefabricated pumping station |
publisher |
MDPI AG |
series |
Energies |
issn |
1996-1073 |
publishDate |
2021-02-01 |
description |
A prefabricated pumping station is a new type of pumping station that plays an important role in the construction of sponge cities in developing countries. It solves the problem of urban water-logging and makes great contributions to the sustainable development of water resources. In order to research the influence of different installation positions of pumps on the internal hydraulic performance of a prefabricated pumping station, based on ANSYS software, the computational fluid dynamics (CFD) numerical simulation method was used to analyze the internal flow state of the prefabricated pump station. In this research, the optimal geometric parameters of pump installation in a prefabricated pumping station are given. The results show that when the distance between the connecting line of two pumps and the center of the sump is <i>L </i>= 0.2 <i>R</i>, the distance between the two pumps is <i>S </i>= 0.6 <i>R</i>, and the suspension height of the two pumps is <i>H </i>= 0.6 <i>D</i>, the internal flow pattern of the prefabricated pump station is better. (<i>R</i> is the cross-sectional radius of the sump and <i>D</i> is the diameter of the nozzle of the pump horn.) These research results have certain guiding significance for improvement of the hydraulic performance and operation efficiency of prefabricated pump stations. They also provide a theoretical basis for parameter selection for prefabricated pumping stations. |
topic |
prefabricated pumping station hydraulic performance geometric parameter installation position numerical simulation |
url |
https://www.mdpi.com/1996-1073/14/4/1039 |
work_keys_str_mv |
AT bowenzhang theinfluenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation AT licheng theinfluenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation AT chunleixu theinfluenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation AT mowang theinfluenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation AT bowenzhang influenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation AT licheng influenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation AT chunleixu influenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation AT mowang influenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation |
_version_ |
1724265857284046848 |