The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station

A prefabricated pumping station is a new type of pumping station that plays an important role in the construction of sponge cities in developing countries. It solves the problem of urban water-logging and makes great contributions to the sustainable development of water resources. In order to resear...

Full description

Bibliographic Details
Main Authors: Bowen Zhang, Li Cheng, Chunlei Xu, Mo Wang
Format: Article
Language:English
Published: MDPI AG 2021-02-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/4/1039
id doaj-ffdf3e1539d64aba90f9e77d4f2a0641
record_format Article
spelling doaj-ffdf3e1539d64aba90f9e77d4f2a06412021-02-17T00:04:16ZengMDPI AGEnergies1996-10732021-02-01141039103910.3390/en14041039The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping StationBowen Zhang0Li Cheng1Chunlei Xu2Mo Wang3College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, ChinaCollege of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, ChinaKey water conservancy project management office, Wuxi 214000, ChinaAnhui Branch of Hainan water resources and Hydropower Survey and Design Institute, Hefei 225000, ChinaA prefabricated pumping station is a new type of pumping station that plays an important role in the construction of sponge cities in developing countries. It solves the problem of urban water-logging and makes great contributions to the sustainable development of water resources. In order to research the influence of different installation positions of pumps on the internal hydraulic performance of a prefabricated pumping station, based on ANSYS software, the computational fluid dynamics (CFD) numerical simulation method was used to analyze the internal flow state of the prefabricated pump station. In this research, the optimal geometric parameters of pump installation in a prefabricated pumping station are given. The results show that when the distance between the connecting line of two pumps and the center of the sump is <i>L </i>= 0.2 <i>R</i>, the distance between the two pumps is <i>S </i>= 0.6 <i>R</i>, and the suspension height of the two pumps is <i>H </i>= 0.6 <i>D</i>, the internal flow pattern of the prefabricated pump station is better. (<i>R</i> is the cross-sectional radius of the sump and <i>D</i> is the diameter of the nozzle of the pump horn.) These research results have certain guiding significance for improvement of the hydraulic performance and operation efficiency of prefabricated pump stations. They also provide a theoretical basis for parameter selection for prefabricated pumping stations.https://www.mdpi.com/1996-1073/14/4/1039prefabricated pumping stationhydraulic performancegeometric parameterinstallation positionnumerical simulation
collection DOAJ
language English
format Article
sources DOAJ
author Bowen Zhang
Li Cheng
Chunlei Xu
Mo Wang
spellingShingle Bowen Zhang
Li Cheng
Chunlei Xu
Mo Wang
The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station
Energies
prefabricated pumping station
hydraulic performance
geometric parameter
installation position
numerical simulation
author_facet Bowen Zhang
Li Cheng
Chunlei Xu
Mo Wang
author_sort Bowen Zhang
title The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station
title_short The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station
title_full The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station
title_fullStr The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station
title_full_unstemmed The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station
title_sort influence of geometric parameters of pump installation on the hydraulic performance of a prefabricated pumping station
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2021-02-01
description A prefabricated pumping station is a new type of pumping station that plays an important role in the construction of sponge cities in developing countries. It solves the problem of urban water-logging and makes great contributions to the sustainable development of water resources. In order to research the influence of different installation positions of pumps on the internal hydraulic performance of a prefabricated pumping station, based on ANSYS software, the computational fluid dynamics (CFD) numerical simulation method was used to analyze the internal flow state of the prefabricated pump station. In this research, the optimal geometric parameters of pump installation in a prefabricated pumping station are given. The results show that when the distance between the connecting line of two pumps and the center of the sump is <i>L </i>= 0.2 <i>R</i>, the distance between the two pumps is <i>S </i>= 0.6 <i>R</i>, and the suspension height of the two pumps is <i>H </i>= 0.6 <i>D</i>, the internal flow pattern of the prefabricated pump station is better. (<i>R</i> is the cross-sectional radius of the sump and <i>D</i> is the diameter of the nozzle of the pump horn.) These research results have certain guiding significance for improvement of the hydraulic performance and operation efficiency of prefabricated pump stations. They also provide a theoretical basis for parameter selection for prefabricated pumping stations.
topic prefabricated pumping station
hydraulic performance
geometric parameter
installation position
numerical simulation
url https://www.mdpi.com/1996-1073/14/4/1039
work_keys_str_mv AT bowenzhang theinfluenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation
AT licheng theinfluenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation
AT chunleixu theinfluenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation
AT mowang theinfluenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation
AT bowenzhang influenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation
AT licheng influenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation
AT chunleixu influenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation
AT mowang influenceofgeometricparametersofpumpinstallationonthehydraulicperformanceofaprefabricatedpumpingstation
_version_ 1724265857284046848