DETERMINATION OF CARBAMATE PESTICIDES USING A BIOSENSOR BASED ON ENZYME ACETYLCHOLINESTERASE AND CHOLIN OXIDASE ON PLATINUM ELECTRODE

In recent years, instead of their potential hazard to human health, carbamic pesticides are widely used in agriculture. Therefore, there is a growing interest in rapid and accurate determination for food safety and environmental monitoring. The aim of this research is to designs a biosensor for anal...

Full description

Bibliographic Details
Main Authors: Mashuni Mashuni, M. Syahrul, A. Ahmad, A. W. Wahab
Format: Article
Language:English
Published: Universitas Gadjah Mada 2010-12-01
Series:Indonesian Journal of Chemistry
Online Access:https://jurnal.ugm.ac.id/ijc/article/view/21432
id doaj-ff97dc28a5114d47b8af1ea48de4e2ee
record_format Article
spelling doaj-ff97dc28a5114d47b8af1ea48de4e2ee2020-11-24T22:02:58ZengUniversitas Gadjah MadaIndonesian Journal of Chemistry1411-94202460-15782010-12-0110329029410.22146/ijc.2143214530DETERMINATION OF CARBAMATE PESTICIDES USING A BIOSENSOR BASED ON ENZYME ACETYLCHOLINESTERASE AND CHOLIN OXIDASE ON PLATINUM ELECTRODEMashuni Mashuni0M. Syahrul1A. Ahmad2A. W. Wahab3Department of Chemistry, Faculty of Mathematics and Natural Sciences, Haluoleo University (UNHALU), Kendari, Sulawesi Tenggara, 93231Department of Chemistry, Faculty of Mathematics and Natural Sciences, Hasanuddin University (UNHAS), Makassar, Sulawesi SelatanDepartment of Chemistry, Faculty of Mathematics and Natural Sciences, Hasanuddin University (UNHAS), Makassar, Sulawesi SelatanDepartment of Chemistry, Faculty of Mathematics and Natural Sciences, Hasanuddin University (UNHAS), Makassar, Sulawesi SelatanIn recent years, instead of their potential hazard to human health, carbamic pesticides are widely used in agriculture. Therefore, there is a growing interest in rapid and accurate determination for food safety and environmental monitoring. The aim of this research is to designs a biosensor for analyzing carbamate pesticides residue in sample with composite variables of glutaraldehyde (GA) concentration in electrode membrane. Enzyme acetylcholinesterase (AChE) was co-immobilised with choline oxidase (ChO) onto a platinum (Pt) surface using a solution of 5%, 10%, 15% cellulose acetate and 25% glutaraldehyde. The result of this research show that detection limit of the sensor using cellulose acetate 5%, 10 % and 15 % are 10-7.7 M, 10-8.7 M and 10-7.6 M respectively. The results are approximately equal to 2.2 ppb-0.2 ppb, which means that this biosensor is very sensitive for determining carbamates pesticides residue. Detection limit of biosensors are comparable to that of the conventional instrument such as Gas Chromatography (GC) and High Pressure Liquid Chromatography (HPLC), i.e. 1.5 ppb and 2.0 ppb respectively. The proposed electrochemical pesticide sensitivity test exhibited high sensitivity, desirable accuracy, low cost and simplified procedure.https://jurnal.ugm.ac.id/ijc/article/view/21432
collection DOAJ
language English
format Article
sources DOAJ
author Mashuni Mashuni
M. Syahrul
A. Ahmad
A. W. Wahab
spellingShingle Mashuni Mashuni
M. Syahrul
A. Ahmad
A. W. Wahab
DETERMINATION OF CARBAMATE PESTICIDES USING A BIOSENSOR BASED ON ENZYME ACETYLCHOLINESTERASE AND CHOLIN OXIDASE ON PLATINUM ELECTRODE
Indonesian Journal of Chemistry
author_facet Mashuni Mashuni
M. Syahrul
A. Ahmad
A. W. Wahab
author_sort Mashuni Mashuni
title DETERMINATION OF CARBAMATE PESTICIDES USING A BIOSENSOR BASED ON ENZYME ACETYLCHOLINESTERASE AND CHOLIN OXIDASE ON PLATINUM ELECTRODE
title_short DETERMINATION OF CARBAMATE PESTICIDES USING A BIOSENSOR BASED ON ENZYME ACETYLCHOLINESTERASE AND CHOLIN OXIDASE ON PLATINUM ELECTRODE
title_full DETERMINATION OF CARBAMATE PESTICIDES USING A BIOSENSOR BASED ON ENZYME ACETYLCHOLINESTERASE AND CHOLIN OXIDASE ON PLATINUM ELECTRODE
title_fullStr DETERMINATION OF CARBAMATE PESTICIDES USING A BIOSENSOR BASED ON ENZYME ACETYLCHOLINESTERASE AND CHOLIN OXIDASE ON PLATINUM ELECTRODE
title_full_unstemmed DETERMINATION OF CARBAMATE PESTICIDES USING A BIOSENSOR BASED ON ENZYME ACETYLCHOLINESTERASE AND CHOLIN OXIDASE ON PLATINUM ELECTRODE
title_sort determination of carbamate pesticides using a biosensor based on enzyme acetylcholinesterase and cholin oxidase on platinum electrode
publisher Universitas Gadjah Mada
series Indonesian Journal of Chemistry
issn 1411-9420
2460-1578
publishDate 2010-12-01
description In recent years, instead of their potential hazard to human health, carbamic pesticides are widely used in agriculture. Therefore, there is a growing interest in rapid and accurate determination for food safety and environmental monitoring. The aim of this research is to designs a biosensor for analyzing carbamate pesticides residue in sample with composite variables of glutaraldehyde (GA) concentration in electrode membrane. Enzyme acetylcholinesterase (AChE) was co-immobilised with choline oxidase (ChO) onto a platinum (Pt) surface using a solution of 5%, 10%, 15% cellulose acetate and 25% glutaraldehyde. The result of this research show that detection limit of the sensor using cellulose acetate 5%, 10 % and 15 % are 10-7.7 M, 10-8.7 M and 10-7.6 M respectively. The results are approximately equal to 2.2 ppb-0.2 ppb, which means that this biosensor is very sensitive for determining carbamates pesticides residue. Detection limit of biosensors are comparable to that of the conventional instrument such as Gas Chromatography (GC) and High Pressure Liquid Chromatography (HPLC), i.e. 1.5 ppb and 2.0 ppb respectively. The proposed electrochemical pesticide sensitivity test exhibited high sensitivity, desirable accuracy, low cost and simplified procedure.
url https://jurnal.ugm.ac.id/ijc/article/view/21432
work_keys_str_mv AT mashunimashuni determinationofcarbamatepesticidesusingabiosensorbasedonenzymeacetylcholinesteraseandcholinoxidaseonplatinumelectrode
AT msyahrul determinationofcarbamatepesticidesusingabiosensorbasedonenzymeacetylcholinesteraseandcholinoxidaseonplatinumelectrode
AT aahmad determinationofcarbamatepesticidesusingabiosensorbasedonenzymeacetylcholinesteraseandcholinoxidaseonplatinumelectrode
AT awwahab determinationofcarbamatepesticidesusingabiosensorbasedonenzymeacetylcholinesteraseandcholinoxidaseonplatinumelectrode
_version_ 1716605033955459072