Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri‐implant bone defects

Abstract Background Early detection of marginal bone loss is vital for treatment planning and prognosis of teeth and implant. This study was conducted to assess diagnostic accuracy of CBCT compared to intra-oral (IO) radiography for detection, classification, and measurement of peri-implant bone def...

Full description

Bibliographic Details
Main Authors: Dandan Song, Sohaib Shujaat, Karla de Faria Vasconcelos, Yan Huang, Constantinus Politis, Ivo Lambrichts, Reinhilde Jacobs
Format: Article
Language:English
Published: BMC 2021-02-01
Series:BMC Medical Imaging
Subjects:
Online Access:https://doi.org/10.1186/s12880-021-00557-9
id doaj-ff903d3278b445b19c8ae3dbeb28b568
record_format Article
spelling doaj-ff903d3278b445b19c8ae3dbeb28b5682021-02-14T12:45:44ZengBMCBMC Medical Imaging1471-23422021-02-012111810.1186/s12880-021-00557-9Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri‐implant bone defectsDandan Song0Sohaib Shujaat1Karla de Faria Vasconcelos2Yan Huang3Constantinus Politis4Ivo Lambrichts5Reinhilde Jacobs6OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals LeuvenOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals LeuvenOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals LeuvenOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals LeuvenOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals LeuvenDepartment of Morphology, Biomedical Research Institute, Hasselt UniversityOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals LeuvenAbstract Background Early detection of marginal bone loss is vital for treatment planning and prognosis of teeth and implant. This study was conducted to assess diagnostic accuracy of CBCT compared to intra-oral (IO) radiography for detection, classification, and measurement of peri-implant bone defects in an animal model. Methods Fifty-four mandible blocks with implants were harvested from nine male health adult beagle dogs with acquisition of IO, CBCT and micro-CT images from all samples. Peri-implant bone defects from 16 samples were diagnosed using micro-CT and classified into 3 defect categories: dehiscence (n = 5), infrabony defect (n = 3) and crater-like defect (n = 8). Following training and calibration of the observers, they asked to detect location (mesial, distal, buccal, lingual) and shape of the defect (dehiscence, horizontal defect, vertical defect, carter-like defect) utilizing both IO and CBCT images. Both observers assessed defect depth and width on IO, CBCT and micro-CT images at each side of peri-implant bone defect via CT-analyzer software. Data were analyzed using SPSS software and a p value of < 0.05 was considered as statistically significant. Results Overall, there was a high diagnostic accuracy for detection of bone defects with CBCT images (sensitivity: 100%/100%), while IO images showed a reduction in accuracy (sensitivity: 69%/63%). Similarly, diagnostic accuracy for defect classification was significantly higher for CBCT, whereas IO images were unable to correctly identify vestibular dehiscence, with incorrect assessment of half of the infrabony defects. For accuracy of measuring defect depth and width, a higher correlation was observed between CBCT and gold standard micro-CT (r = 0.91, 95% CI 0.86–0.94), whereas a lower correlation was seen for IO images (r = 0.82, 95% CI 0.67–0.91). Conclusions The diagnostic accuracy and reliability of CBCT was found to be superior to IO imaging for the detection, classification, and measurement of peri-implant bone defects. The application of CBCT adds substantial information related to the peri-implant bone defect diagnosis and decision-making which cannot be achieved with conventional IO imaging.https://doi.org/10.1186/s12880-021-00557-9Alveolar bone lossPeri‐implantitisCBCTDental radiography
collection DOAJ
language English
format Article
sources DOAJ
author Dandan Song
Sohaib Shujaat
Karla de Faria Vasconcelos
Yan Huang
Constantinus Politis
Ivo Lambrichts
Reinhilde Jacobs
spellingShingle Dandan Song
Sohaib Shujaat
Karla de Faria Vasconcelos
Yan Huang
Constantinus Politis
Ivo Lambrichts
Reinhilde Jacobs
Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri‐implant bone defects
BMC Medical Imaging
Alveolar bone loss
Peri‐implantitis
CBCT
Dental radiography
author_facet Dandan Song
Sohaib Shujaat
Karla de Faria Vasconcelos
Yan Huang
Constantinus Politis
Ivo Lambrichts
Reinhilde Jacobs
author_sort Dandan Song
title Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri‐implant bone defects
title_short Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri‐implant bone defects
title_full Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri‐implant bone defects
title_fullStr Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri‐implant bone defects
title_full_unstemmed Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri‐implant bone defects
title_sort diagnostic accuracy of cbct versus intraoral imaging for assessment of peri‐implant bone defects
publisher BMC
series BMC Medical Imaging
issn 1471-2342
publishDate 2021-02-01
description Abstract Background Early detection of marginal bone loss is vital for treatment planning and prognosis of teeth and implant. This study was conducted to assess diagnostic accuracy of CBCT compared to intra-oral (IO) radiography for detection, classification, and measurement of peri-implant bone defects in an animal model. Methods Fifty-four mandible blocks with implants were harvested from nine male health adult beagle dogs with acquisition of IO, CBCT and micro-CT images from all samples. Peri-implant bone defects from 16 samples were diagnosed using micro-CT and classified into 3 defect categories: dehiscence (n = 5), infrabony defect (n = 3) and crater-like defect (n = 8). Following training and calibration of the observers, they asked to detect location (mesial, distal, buccal, lingual) and shape of the defect (dehiscence, horizontal defect, vertical defect, carter-like defect) utilizing both IO and CBCT images. Both observers assessed defect depth and width on IO, CBCT and micro-CT images at each side of peri-implant bone defect via CT-analyzer software. Data were analyzed using SPSS software and a p value of < 0.05 was considered as statistically significant. Results Overall, there was a high diagnostic accuracy for detection of bone defects with CBCT images (sensitivity: 100%/100%), while IO images showed a reduction in accuracy (sensitivity: 69%/63%). Similarly, diagnostic accuracy for defect classification was significantly higher for CBCT, whereas IO images were unable to correctly identify vestibular dehiscence, with incorrect assessment of half of the infrabony defects. For accuracy of measuring defect depth and width, a higher correlation was observed between CBCT and gold standard micro-CT (r = 0.91, 95% CI 0.86–0.94), whereas a lower correlation was seen for IO images (r = 0.82, 95% CI 0.67–0.91). Conclusions The diagnostic accuracy and reliability of CBCT was found to be superior to IO imaging for the detection, classification, and measurement of peri-implant bone defects. The application of CBCT adds substantial information related to the peri-implant bone defect diagnosis and decision-making which cannot be achieved with conventional IO imaging.
topic Alveolar bone loss
Peri‐implantitis
CBCT
Dental radiography
url https://doi.org/10.1186/s12880-021-00557-9
work_keys_str_mv AT dandansong diagnosticaccuracyofcbctversusintraoralimagingforassessmentofperiimplantbonedefects
AT sohaibshujaat diagnosticaccuracyofcbctversusintraoralimagingforassessmentofperiimplantbonedefects
AT karladefariavasconcelos diagnosticaccuracyofcbctversusintraoralimagingforassessmentofperiimplantbonedefects
AT yanhuang diagnosticaccuracyofcbctversusintraoralimagingforassessmentofperiimplantbonedefects
AT constantinuspolitis diagnosticaccuracyofcbctversusintraoralimagingforassessmentofperiimplantbonedefects
AT ivolambrichts diagnosticaccuracyofcbctversusintraoralimagingforassessmentofperiimplantbonedefects
AT reinhildejacobs diagnosticaccuracyofcbctversusintraoralimagingforassessmentofperiimplantbonedefects
_version_ 1724270122779017216