Improvement of the Efficiency of the Axial-Flow Pump at Part Loads due to Installing Outlet Guide Vanes Mechanism
In order to investigate the influence of adjustable outlet guide vane on the hydraulic performance of axial-flow pump at part loads, the axial-flow pump with 7 different outlet guide vane adjustable angles was simulated based on the RNG k-ε turbulent model and Reynolds time-averaged equations. The V...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2016-01-01
|
Series: | Mathematical Problems in Engineering |
Online Access: | http://dx.doi.org/10.1155/2016/6375314 |
id |
doaj-ff8ebbb0c2e043d5a595b1c52d5f78aa |
---|---|
record_format |
Article |
spelling |
doaj-ff8ebbb0c2e043d5a595b1c52d5f78aa2020-11-24T23:53:32ZengHindawi LimitedMathematical Problems in Engineering1024-123X1563-51472016-01-01201610.1155/2016/63753146375314Improvement of the Efficiency of the Axial-Flow Pump at Part Loads due to Installing Outlet Guide Vanes MechanismFan Yang0Hao-ru Zhao1Chao Liu2School of Hydraulic, Energy and Power Engineering, Yangzhou University, Jiangsu, ChinaSchool of Hydraulic, Energy and Power Engineering, Yangzhou University, Jiangsu, ChinaSchool of Hydraulic, Energy and Power Engineering, Yangzhou University, Jiangsu, ChinaIn order to investigate the influence of adjustable outlet guide vane on the hydraulic performance of axial-flow pump at part loads, the axial-flow pump with 7 different outlet guide vane adjustable angles was simulated based on the RNG k-ε turbulent model and Reynolds time-averaged equations. The Vector graphs of airfoil flow were analyzed in the different operating conditions for different adjustable angles of guide vane. BP-ANN prediction model was established about the effect of adjustable outlet guide vane on the hydraulic performance of axial-flow pump based on the numerical results. The effectiveness of prediction model was verified by theoretical analysis and numerical simulation. The results show that, with the adjustable angle of guide vane increasing along clockwise, the high efficiency area moves to the large flow rate direction; otherwise, that moves to the small flow rate direction. The internal flow field of guide vane is improved by adjusting angle, and the flow separation of tail and guide vane inlet ledge are decreased or eliminated, so that the hydraulic efficiency of pumping system will be improved. The prediction accuracy of BP-ANN model is 1%, which can meet the requirement of practical engineering.http://dx.doi.org/10.1155/2016/6375314 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Fan Yang Hao-ru Zhao Chao Liu |
spellingShingle |
Fan Yang Hao-ru Zhao Chao Liu Improvement of the Efficiency of the Axial-Flow Pump at Part Loads due to Installing Outlet Guide Vanes Mechanism Mathematical Problems in Engineering |
author_facet |
Fan Yang Hao-ru Zhao Chao Liu |
author_sort |
Fan Yang |
title |
Improvement of the Efficiency of the Axial-Flow Pump at Part Loads due to Installing Outlet Guide Vanes Mechanism |
title_short |
Improvement of the Efficiency of the Axial-Flow Pump at Part Loads due to Installing Outlet Guide Vanes Mechanism |
title_full |
Improvement of the Efficiency of the Axial-Flow Pump at Part Loads due to Installing Outlet Guide Vanes Mechanism |
title_fullStr |
Improvement of the Efficiency of the Axial-Flow Pump at Part Loads due to Installing Outlet Guide Vanes Mechanism |
title_full_unstemmed |
Improvement of the Efficiency of the Axial-Flow Pump at Part Loads due to Installing Outlet Guide Vanes Mechanism |
title_sort |
improvement of the efficiency of the axial-flow pump at part loads due to installing outlet guide vanes mechanism |
publisher |
Hindawi Limited |
series |
Mathematical Problems in Engineering |
issn |
1024-123X 1563-5147 |
publishDate |
2016-01-01 |
description |
In order to investigate the influence of adjustable outlet guide vane on the hydraulic performance of axial-flow pump at part loads, the axial-flow pump with 7 different outlet guide vane adjustable angles was simulated based on the RNG k-ε turbulent model and Reynolds time-averaged equations. The Vector graphs of airfoil flow were analyzed in the different operating conditions for different adjustable angles of guide vane. BP-ANN prediction model was established about the effect of adjustable outlet guide vane on the hydraulic performance of axial-flow pump based on the numerical results. The effectiveness of prediction model was verified by theoretical analysis and numerical simulation. The results show that, with the adjustable angle of guide vane increasing along clockwise, the high efficiency area moves to the large flow rate direction; otherwise, that moves to the small flow rate direction. The internal flow field of guide vane is improved by adjusting angle, and the flow separation of tail and guide vane inlet ledge are decreased or eliminated, so that the hydraulic efficiency of pumping system will be improved. The prediction accuracy of BP-ANN model is 1%, which can meet the requirement of practical engineering. |
url |
http://dx.doi.org/10.1155/2016/6375314 |
work_keys_str_mv |
AT fanyang improvementoftheefficiencyoftheaxialflowpumpatpartloadsduetoinstallingoutletguidevanesmechanism AT haoruzhao improvementoftheefficiencyoftheaxialflowpumpatpartloadsduetoinstallingoutletguidevanesmechanism AT chaoliu improvementoftheefficiencyoftheaxialflowpumpatpartloadsduetoinstallingoutletguidevanesmechanism |
_version_ |
1725469216597868544 |