Comparison of the Orotracheal Tube Cuff Pressure Estimated by Palpation vs. the Measurement Taken with a Manometer

The pressure exerted by the cuff of endotracheal tube (ETT) on the mucosa to be blown, should be kept in a safe range to avoid complications by on inflation or deflation. In our context, the objective measurement instruments are not commonly used. Objective: To evaluate the correlation between ETT c...

Full description

Bibliographic Details
Main Authors: Mojica S, Muñoz VE, Gómez JM, Soto R
Format: Article
Language:Spanish
Published: Universidad Colegio Mayor Nuestra Señora del Rosario 2011-12-01
Series:Revista Ciencias de la Salud
Subjects:
Online Access:http://revistas.urosario.edu.co/index.php/revsalud/article/view/1820/1652
id doaj-ff6cda14f3ae4b7f9cfe9e11923851d3
record_format Article
spelling doaj-ff6cda14f3ae4b7f9cfe9e11923851d32021-03-02T08:39:45ZspaUniversidad Colegio Mayor Nuestra Señora del RosarioRevista Ciencias de la Salud1692-72732011-12-0193229236Comparison of the Orotracheal Tube Cuff Pressure Estimated by Palpation vs. the Measurement Taken with a ManometerMojica SMuñoz VEGómez JMSoto RThe pressure exerted by the cuff of endotracheal tube (ETT) on the mucosa to be blown, should be kept in a safe range to avoid complications by on inflation or deflation. In our context, the objective measurement instruments are not commonly used. Objective: To evaluate the correlation between ETT cuff pressure estimated by palpation, and that obtained with a manual gauge in adult patients undergoing general anesthesia. Materials and methods: It was performed a cross-sectional study by obtaining the sample of adult patients undergoing general anesthesia requiring endotracheal intubation. We included forty patients who were intubated and then two blind anesthesiologists, other than the one who intubated, estimated insufflation of ETT cuff by palpation categorizing as over-inflated, normal or deflated. One of the observers subsequently, carried out the measurement of pressure with a manometer, both in inspiration and expiration. It was considered as normal pressure range 20 to 30 cm H2O. Results: The correlation of the estimation by palpation between the two anesthesiologists was weak (Kappa = 0.21, ES: 0.11). The correlation of the estimation by palpation and measurement with manual gauge was very weak. Between the first anesthesiologist and observers, in inspiration the κ was 0.08 (ES: 0.09), in expiration was 0.08 (ES: 0.07), also between the second anesthesiologist and the observers, κ 0.05 (ES: 0.07) and 0.02 (ES: 0.06) respectively. Conclusion: The study shows that the correlation between subjective and objective methods to determine if the cuff of ETT is properly inflated was weak. It suggests the use of more objective methods for its determination.http://revistas.urosario.edu.co/index.php/revsalud/article/view/1820/1652cuff pressureorotracheal intubationtracheal injuryestimation techniques
collection DOAJ
language Spanish
format Article
sources DOAJ
author Mojica S
Muñoz VE
Gómez JM
Soto R
spellingShingle Mojica S
Muñoz VE
Gómez JM
Soto R
Comparison of the Orotracheal Tube Cuff Pressure Estimated by Palpation vs. the Measurement Taken with a Manometer
Revista Ciencias de la Salud
cuff pressure
orotracheal intubation
tracheal injury
estimation techniques
author_facet Mojica S
Muñoz VE
Gómez JM
Soto R
author_sort Mojica S
title Comparison of the Orotracheal Tube Cuff Pressure Estimated by Palpation vs. the Measurement Taken with a Manometer
title_short Comparison of the Orotracheal Tube Cuff Pressure Estimated by Palpation vs. the Measurement Taken with a Manometer
title_full Comparison of the Orotracheal Tube Cuff Pressure Estimated by Palpation vs. the Measurement Taken with a Manometer
title_fullStr Comparison of the Orotracheal Tube Cuff Pressure Estimated by Palpation vs. the Measurement Taken with a Manometer
title_full_unstemmed Comparison of the Orotracheal Tube Cuff Pressure Estimated by Palpation vs. the Measurement Taken with a Manometer
title_sort comparison of the orotracheal tube cuff pressure estimated by palpation vs. the measurement taken with a manometer
publisher Universidad Colegio Mayor Nuestra Señora del Rosario
series Revista Ciencias de la Salud
issn 1692-7273
publishDate 2011-12-01
description The pressure exerted by the cuff of endotracheal tube (ETT) on the mucosa to be blown, should be kept in a safe range to avoid complications by on inflation or deflation. In our context, the objective measurement instruments are not commonly used. Objective: To evaluate the correlation between ETT cuff pressure estimated by palpation, and that obtained with a manual gauge in adult patients undergoing general anesthesia. Materials and methods: It was performed a cross-sectional study by obtaining the sample of adult patients undergoing general anesthesia requiring endotracheal intubation. We included forty patients who were intubated and then two blind anesthesiologists, other than the one who intubated, estimated insufflation of ETT cuff by palpation categorizing as over-inflated, normal or deflated. One of the observers subsequently, carried out the measurement of pressure with a manometer, both in inspiration and expiration. It was considered as normal pressure range 20 to 30 cm H2O. Results: The correlation of the estimation by palpation between the two anesthesiologists was weak (Kappa = 0.21, ES: 0.11). The correlation of the estimation by palpation and measurement with manual gauge was very weak. Between the first anesthesiologist and observers, in inspiration the κ was 0.08 (ES: 0.09), in expiration was 0.08 (ES: 0.07), also between the second anesthesiologist and the observers, κ 0.05 (ES: 0.07) and 0.02 (ES: 0.06) respectively. Conclusion: The study shows that the correlation between subjective and objective methods to determine if the cuff of ETT is properly inflated was weak. It suggests the use of more objective methods for its determination.
topic cuff pressure
orotracheal intubation
tracheal injury
estimation techniques
url http://revistas.urosario.edu.co/index.php/revsalud/article/view/1820/1652
work_keys_str_mv AT mojicas comparisonoftheorotrachealtubecuffpressureestimatedbypalpationvsthemeasurementtakenwithamanometer
AT munozve comparisonoftheorotrachealtubecuffpressureestimatedbypalpationvsthemeasurementtakenwithamanometer
AT gomezjm comparisonoftheorotrachealtubecuffpressureestimatedbypalpationvsthemeasurementtakenwithamanometer
AT sotor comparisonoftheorotrachealtubecuffpressureestimatedbypalpationvsthemeasurementtakenwithamanometer
_version_ 1724240578273607680