Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications

A rapid sensitive and selective MRM based method for the determination of Cremophor EL (CrEL) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). CrEL and polypropylene glycol (internal standard) were extracted from rat plasma with acetonitrile and analysed o...

Full description

Bibliographic Details
Main Authors: V. Vijaya Bhaskar, Anil Middha
Format: Article
Language:English
Published: Hindawi Limited 2013-01-01
Series:International Journal of Analytical Chemistry
Online Access:http://dx.doi.org/10.1155/2013/135613
id doaj-ff4ae07764044f7e9a87b74f7b727842
record_format Article
spelling doaj-ff4ae07764044f7e9a87b74f7b7278422020-11-25T01:41:17ZengHindawi LimitedInternational Journal of Analytical Chemistry1687-87601687-87792013-01-01201310.1155/2013/135613135613Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its ApplicationsV. Vijaya Bhaskar0Anil Middha1Department of Pharmacy, Jagadishprasad Jhabermal Tibrewala University, Vidyanagari, Jhunjhunu, Rajasthan 333001, IndiaDepartment of Pharmacy, Jagadishprasad Jhabermal Tibrewala University, Vidyanagari, Jhunjhunu, Rajasthan 333001, IndiaA rapid sensitive and selective MRM based method for the determination of Cremophor EL (CrEL) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). CrEL and polypropylene glycol (internal standard) were extracted from rat plasma with acetonitrile and analysed on C18 column (XBridge, 50 × 4.6 mm, 3.5 μm). The most abundant molecular ions corresponding to PEG oligomers at m/z 828, 872, 916 and 960 with daughter ion at m/z 89 were selected for multiple reaction monitoring (MRM) in electrospray mode of ionisation. Plasma concentrations of CrEL were quantified after administration through oral and intravenous routes in male sprague dawley rats at a dose of 0.26 g/kg. The standard curve was linear (0.9972) over the concentration range of 1.00 to 200 μg/mL. The lower limit of quantitation for CrEL was 1.00 μg/mL using 50 μL plasma. The coefficient of variation and relative error for inter and intra assay at three QC levels were 0.69 to 9.21 and −7.60 to 4.74 respectively. A novel proposal was conveyed to the scientific community, where formulation excipient can be analysed as qualifier in the analysis of NCEs to address the spiky plasma concentration profiles.http://dx.doi.org/10.1155/2013/135613
collection DOAJ
language English
format Article
sources DOAJ
author V. Vijaya Bhaskar
Anil Middha
spellingShingle V. Vijaya Bhaskar
Anil Middha
Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
International Journal of Analytical Chemistry
author_facet V. Vijaya Bhaskar
Anil Middha
author_sort V. Vijaya Bhaskar
title Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title_short Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title_full Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title_fullStr Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title_full_unstemmed Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title_sort liquid chromatography/tandem mass spectrometry method for quantitation of cremophor el and its applications
publisher Hindawi Limited
series International Journal of Analytical Chemistry
issn 1687-8760
1687-8779
publishDate 2013-01-01
description A rapid sensitive and selective MRM based method for the determination of Cremophor EL (CrEL) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). CrEL and polypropylene glycol (internal standard) were extracted from rat plasma with acetonitrile and analysed on C18 column (XBridge, 50 × 4.6 mm, 3.5 μm). The most abundant molecular ions corresponding to PEG oligomers at m/z 828, 872, 916 and 960 with daughter ion at m/z 89 were selected for multiple reaction monitoring (MRM) in electrospray mode of ionisation. Plasma concentrations of CrEL were quantified after administration through oral and intravenous routes in male sprague dawley rats at a dose of 0.26 g/kg. The standard curve was linear (0.9972) over the concentration range of 1.00 to 200 μg/mL. The lower limit of quantitation for CrEL was 1.00 μg/mL using 50 μL plasma. The coefficient of variation and relative error for inter and intra assay at three QC levels were 0.69 to 9.21 and −7.60 to 4.74 respectively. A novel proposal was conveyed to the scientific community, where formulation excipient can be analysed as qualifier in the analysis of NCEs to address the spiky plasma concentration profiles.
url http://dx.doi.org/10.1155/2013/135613
work_keys_str_mv AT vvijayabhaskar liquidchromatographytandemmassspectrometrymethodforquantitationofcremophorelanditsapplications
AT anilmiddha liquidchromatographytandemmassspectrometrymethodforquantitationofcremophorelanditsapplications
_version_ 1725041718700539904