Prospective randomized study comparing the Teleflex Medical SaphLITE Retractor to the Ethicon CardioVations Clearglide Endoscopic System

<p>Abstract</p> <p>Background</p> <p>Several minimally invasive saphenous vein harvesting techniques have been developed to reduce morbidities associated with coronary artery bypass grafting. This prospective, randomized study was designed to compare two commonly used m...

Full description

Bibliographic Details
Main Authors: Schultz Scot C, Stapleton Dennis, D'Ambra Paula, Loftis Cynthia, Wahrmann Christine, Ebra George
Format: Article
Language:English
Published: BMC 2006-09-01
Series:Journal of Cardiothoracic Surgery
Online Access:http://www.cardiothoracicsurgery.org/content/1/1/24
id doaj-ff0f7abf79c2461cba6d7ef3ee11287d
record_format Article
spelling doaj-ff0f7abf79c2461cba6d7ef3ee11287d2020-11-24T23:28:39ZengBMCJournal of Cardiothoracic Surgery1749-80902006-09-01112410.1186/1749-8090-1-24Prospective randomized study comparing the Teleflex Medical SaphLITE Retractor to the Ethicon CardioVations Clearglide Endoscopic SystemSchultz Scot CStapleton DennisD'Ambra PaulaLoftis CynthiaWahrmann ChristineEbra George<p>Abstract</p> <p>Background</p> <p>Several minimally invasive saphenous vein harvesting techniques have been developed to reduce morbidities associated with coronary artery bypass grafting. This prospective, randomized study was designed to compare two commonly used minimally invasive saphenous vein harvesting techniques, the SaphLITE Retractor System (Teleflex Medical) and the Clearglide Endoscopic Vessel Harvesting System (Ethicon CardioVations, Inc.).</p> <p>Methods</p> <p>Between January 2003 and March 2004, a total of 200 patients scheduled for primary, nonemergent coronary artery bypass grafting, with or without concomitant procedures were randomized into two groups: SaphLITE (n = 100) and Clearglide (n = 100). Pre-, intra- and postoperative data was collected and subjected to statistical analysis. Randomization provided homogenous groups with respect to preoperative risk factors.</p> <p>Results</p> <p>Harvest location for the SaphLITE group was thigh (n = 40), lower leg (n = 5) and both lower leg and thigh (n = 55). The location of harvest for the Clearglide group was thigh (n = 3), lower leg (n = 16) and both lower leg and thigh (n = 81). The mean incision length was 3.6 cm (range, 2–6) in the SaphLITE group versus 2.1 cm (range, 1–4) in the Clearglide group (p < 0.05). The total incision length was 12.9 cm versus 8.9 (p < 0.05) in the SaphLITE and Clearglide groups. Conversion to the open technique occurred in 5 SaphLITE patients and 7 Clearglide patients. Intraoperative leg exploration for bleeding occurred in two of the Clearglide patients and none of the SaphLITE patients. Post-operative complications specifically related to minimally invasive harvesting technique, including a two-week post-discharge visit, were not statistically different between the groups.</p> <p>Conclusion</p> <p>The saphenous vein can be safely harvested utilizing the SaphLITE and Clearglide systems. While the Clearglide system allows for fewer incisions (number and length) and less harvest time, these benefits may be outweighed by the increased cost of the Clearglide system compared to the SaphLITE retractor.</p> http://www.cardiothoracicsurgery.org/content/1/1/24
collection DOAJ
language English
format Article
sources DOAJ
author Schultz Scot C
Stapleton Dennis
D'Ambra Paula
Loftis Cynthia
Wahrmann Christine
Ebra George
spellingShingle Schultz Scot C
Stapleton Dennis
D'Ambra Paula
Loftis Cynthia
Wahrmann Christine
Ebra George
Prospective randomized study comparing the Teleflex Medical SaphLITE Retractor to the Ethicon CardioVations Clearglide Endoscopic System
Journal of Cardiothoracic Surgery
author_facet Schultz Scot C
Stapleton Dennis
D'Ambra Paula
Loftis Cynthia
Wahrmann Christine
Ebra George
author_sort Schultz Scot C
title Prospective randomized study comparing the Teleflex Medical SaphLITE Retractor to the Ethicon CardioVations Clearglide Endoscopic System
title_short Prospective randomized study comparing the Teleflex Medical SaphLITE Retractor to the Ethicon CardioVations Clearglide Endoscopic System
title_full Prospective randomized study comparing the Teleflex Medical SaphLITE Retractor to the Ethicon CardioVations Clearglide Endoscopic System
title_fullStr Prospective randomized study comparing the Teleflex Medical SaphLITE Retractor to the Ethicon CardioVations Clearglide Endoscopic System
title_full_unstemmed Prospective randomized study comparing the Teleflex Medical SaphLITE Retractor to the Ethicon CardioVations Clearglide Endoscopic System
title_sort prospective randomized study comparing the teleflex medical saphlite retractor to the ethicon cardiovations clearglide endoscopic system
publisher BMC
series Journal of Cardiothoracic Surgery
issn 1749-8090
publishDate 2006-09-01
description <p>Abstract</p> <p>Background</p> <p>Several minimally invasive saphenous vein harvesting techniques have been developed to reduce morbidities associated with coronary artery bypass grafting. This prospective, randomized study was designed to compare two commonly used minimally invasive saphenous vein harvesting techniques, the SaphLITE Retractor System (Teleflex Medical) and the Clearglide Endoscopic Vessel Harvesting System (Ethicon CardioVations, Inc.).</p> <p>Methods</p> <p>Between January 2003 and March 2004, a total of 200 patients scheduled for primary, nonemergent coronary artery bypass grafting, with or without concomitant procedures were randomized into two groups: SaphLITE (n = 100) and Clearglide (n = 100). Pre-, intra- and postoperative data was collected and subjected to statistical analysis. Randomization provided homogenous groups with respect to preoperative risk factors.</p> <p>Results</p> <p>Harvest location for the SaphLITE group was thigh (n = 40), lower leg (n = 5) and both lower leg and thigh (n = 55). The location of harvest for the Clearglide group was thigh (n = 3), lower leg (n = 16) and both lower leg and thigh (n = 81). The mean incision length was 3.6 cm (range, 2–6) in the SaphLITE group versus 2.1 cm (range, 1–4) in the Clearglide group (p < 0.05). The total incision length was 12.9 cm versus 8.9 (p < 0.05) in the SaphLITE and Clearglide groups. Conversion to the open technique occurred in 5 SaphLITE patients and 7 Clearglide patients. Intraoperative leg exploration for bleeding occurred in two of the Clearglide patients and none of the SaphLITE patients. Post-operative complications specifically related to minimally invasive harvesting technique, including a two-week post-discharge visit, were not statistically different between the groups.</p> <p>Conclusion</p> <p>The saphenous vein can be safely harvested utilizing the SaphLITE and Clearglide systems. While the Clearglide system allows for fewer incisions (number and length) and less harvest time, these benefits may be outweighed by the increased cost of the Clearglide system compared to the SaphLITE retractor.</p>
url http://www.cardiothoracicsurgery.org/content/1/1/24
work_keys_str_mv AT schultzscotc prospectiverandomizedstudycomparingtheteleflexmedicalsaphliteretractortotheethiconcardiovationsclearglideendoscopicsystem
AT stapletondennis prospectiverandomizedstudycomparingtheteleflexmedicalsaphliteretractortotheethiconcardiovationsclearglideendoscopicsystem
AT dambrapaula prospectiverandomizedstudycomparingtheteleflexmedicalsaphliteretractortotheethiconcardiovationsclearglideendoscopicsystem
AT loftiscynthia prospectiverandomizedstudycomparingtheteleflexmedicalsaphliteretractortotheethiconcardiovationsclearglideendoscopicsystem
AT wahrmannchristine prospectiverandomizedstudycomparingtheteleflexmedicalsaphliteretractortotheethiconcardiovationsclearglideendoscopicsystem
AT ebrageorge prospectiverandomizedstudycomparingtheteleflexmedicalsaphliteretractortotheethiconcardiovationsclearglideendoscopicsystem
_version_ 1725548549738856448