Interfacial Electric Effects on a Non-Isothermal Electroosmotic Flow in a Microcapillary Tube Filled by Two Immiscible Fluids

In this work, a non-isothermal electroosmotic flow of two immiscible fluids within a uniform microcapillary is theoretically studied. It is considered that there is an annular layer of a non-Newtonian liquid, whose behavior follows the power-law model, adjacent to the inside wall of the capillary, w...

Full description

Bibliographic Details
Main Authors: Andrés Matías, Federico Méndez, Oscar Bautista
Format: Article
Language:English
Published: MDPI AG 2017-07-01
Series:Micromachines
Subjects:
Online Access:https://www.mdpi.com/2072-666X/8/8/232
id doaj-fef4ccc4dd9a4f2895da1df231dc00c7
record_format Article
spelling doaj-fef4ccc4dd9a4f2895da1df231dc00c72020-11-25T01:42:57ZengMDPI AGMicromachines2072-666X2017-07-018823210.3390/mi8080232mi8080232Interfacial Electric Effects on a Non-Isothermal Electroosmotic Flow in a Microcapillary Tube Filled by Two Immiscible FluidsAndrés Matías0Federico Méndez1Oscar Bautista2Facultad de Ingeniería, Departamento de Termofluidos, Universidad Nacional Autónoma de México (UNAM), México City 04510, MexicoFacultad de Ingeniería, Departamento de Termofluidos, Universidad Nacional Autónoma de México (UNAM), México City 04510, MexicoSEPI-ESIME Azcapotzalco, Instituto Politécnico Nacional (IPN), México City 02250, MexicoIn this work, a non-isothermal electroosmotic flow of two immiscible fluids within a uniform microcapillary is theoretically studied. It is considered that there is an annular layer of a non-Newtonian liquid, whose behavior follows the power-law model, adjacent to the inside wall of the capillary, which in turn surrounds an inner flow of a second conducting liquid that is driven by electroosmosis. The inner fluid flow exerts an interfacial force, dragging the annular fluid due to shear and Maxwell stresses at the interface between the two fluids. Because the Joule heating effect may be present in electroosmotic flow (EOF), temperature gradients can appear along the microcapillary, making the viscosity coefficients of both fluids and the electrical conductivity of the inner fluid temperature dependent. The above makes the variables of the flow field in both fluids, velocity, pressure, temperature and electric fields, coupled. An additional complexity of the mathematical model that describes the electroosmotic flow is the nonlinear character due to the rheological behavior of the surrounding fluid. Therefore, based on the lubrication theory approximation, the governing equations are nondimensionalized and simplified, and an asymptotic solution is determined using a regular perturbation technique by considering that the perturbation parameter is associated with changes in the viscosity by temperature effects. The principal results showed that the parameters that notably influence the flow field are the power-law index, an electrokinetic parameter (the ratio between the radius of the microchannel and the Debye length) and the competition between the consistency index of the non-Newtonian fluid and the viscosity of the conducting fluid. Additionally, the heat that is dissipated trough the external surface of the microchannel and the sensitivity of the viscosity to temperature changes play important roles, which modify the flow field.https://www.mdpi.com/2072-666X/8/8/232power-law fluidelectroosmotic flowimmiscible fluidsnon-isothermalmicrocapillaryMaxwell stress
collection DOAJ
language English
format Article
sources DOAJ
author Andrés Matías
Federico Méndez
Oscar Bautista
spellingShingle Andrés Matías
Federico Méndez
Oscar Bautista
Interfacial Electric Effects on a Non-Isothermal Electroosmotic Flow in a Microcapillary Tube Filled by Two Immiscible Fluids
Micromachines
power-law fluid
electroosmotic flow
immiscible fluids
non-isothermal
microcapillary
Maxwell stress
author_facet Andrés Matías
Federico Méndez
Oscar Bautista
author_sort Andrés Matías
title Interfacial Electric Effects on a Non-Isothermal Electroosmotic Flow in a Microcapillary Tube Filled by Two Immiscible Fluids
title_short Interfacial Electric Effects on a Non-Isothermal Electroosmotic Flow in a Microcapillary Tube Filled by Two Immiscible Fluids
title_full Interfacial Electric Effects on a Non-Isothermal Electroosmotic Flow in a Microcapillary Tube Filled by Two Immiscible Fluids
title_fullStr Interfacial Electric Effects on a Non-Isothermal Electroosmotic Flow in a Microcapillary Tube Filled by Two Immiscible Fluids
title_full_unstemmed Interfacial Electric Effects on a Non-Isothermal Electroosmotic Flow in a Microcapillary Tube Filled by Two Immiscible Fluids
title_sort interfacial electric effects on a non-isothermal electroosmotic flow in a microcapillary tube filled by two immiscible fluids
publisher MDPI AG
series Micromachines
issn 2072-666X
publishDate 2017-07-01
description In this work, a non-isothermal electroosmotic flow of two immiscible fluids within a uniform microcapillary is theoretically studied. It is considered that there is an annular layer of a non-Newtonian liquid, whose behavior follows the power-law model, adjacent to the inside wall of the capillary, which in turn surrounds an inner flow of a second conducting liquid that is driven by electroosmosis. The inner fluid flow exerts an interfacial force, dragging the annular fluid due to shear and Maxwell stresses at the interface between the two fluids. Because the Joule heating effect may be present in electroosmotic flow (EOF), temperature gradients can appear along the microcapillary, making the viscosity coefficients of both fluids and the electrical conductivity of the inner fluid temperature dependent. The above makes the variables of the flow field in both fluids, velocity, pressure, temperature and electric fields, coupled. An additional complexity of the mathematical model that describes the electroosmotic flow is the nonlinear character due to the rheological behavior of the surrounding fluid. Therefore, based on the lubrication theory approximation, the governing equations are nondimensionalized and simplified, and an asymptotic solution is determined using a regular perturbation technique by considering that the perturbation parameter is associated with changes in the viscosity by temperature effects. The principal results showed that the parameters that notably influence the flow field are the power-law index, an electrokinetic parameter (the ratio between the radius of the microchannel and the Debye length) and the competition between the consistency index of the non-Newtonian fluid and the viscosity of the conducting fluid. Additionally, the heat that is dissipated trough the external surface of the microchannel and the sensitivity of the viscosity to temperature changes play important roles, which modify the flow field.
topic power-law fluid
electroosmotic flow
immiscible fluids
non-isothermal
microcapillary
Maxwell stress
url https://www.mdpi.com/2072-666X/8/8/232
work_keys_str_mv AT andresmatias interfacialelectriceffectsonanonisothermalelectroosmoticflowinamicrocapillarytubefilledbytwoimmisciblefluids
AT federicomendez interfacialelectriceffectsonanonisothermalelectroosmoticflowinamicrocapillarytubefilledbytwoimmisciblefluids
AT oscarbautista interfacialelectriceffectsonanonisothermalelectroosmoticflowinamicrocapillarytubefilledbytwoimmisciblefluids
_version_ 1725034077237542912