Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis

Background and Aims: To find out the primary stability in maxillofacial implant with two different thread designs. Methods: Two group of implants were selected for the study – Group I maxillofacial implant with V-shape thread, and Group II implant with buttress thread. The drills for placing the imp...

Full description

Bibliographic Details
Main Authors: Karthikeyan Ramkumar, S Sripriya, A Meenakshi, C Sabarigirinathan, C Thulasingam
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2020-01-01
Series:Indian Journal of Dental Research
Subjects:
Online Access:http://www.ijdr.in/article.asp?issn=0970-9290;year=2020;volume=31;issue=3;spage=403;epage=407;aulast=Ramkumar
id doaj-febd6e9b82bf46009f7d20cc6b69655b
record_format Article
spelling doaj-febd6e9b82bf46009f7d20cc6b69655b2020-11-25T02:00:22ZengWolters Kluwer Medknow PublicationsIndian Journal of Dental Research0970-92901998-36032020-01-0131340340710.4103/ijdr.IJDR_447_17Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysisKarthikeyan RamkumarS SripriyaA MeenakshiC SabarigirinathanC ThulasingamBackground and Aims: To find out the primary stability in maxillofacial implant with two different thread designs. Methods: Two group of implants were selected for the study – Group I maxillofacial implant with V-shape thread, and Group II implant with buttress thread. The drills for placing the implant were made indigenously. Goat skull was selected for placing the implant. Group I, II implant was placed in the goat skull at five different sites to find the primary stability. The primary stability was measured using Resonance Frequency Analysis (RFA) device. The transducer was screwed to the implant and made to vibrate by magnetic pulse. The vibration was recorded as Implant Stability Quotient (ISQ). Results: The ISQ values of Group I range from 32-46 and Group II range from 57-67. The results were subjected to statistical test and found to be significant at 95% level. Conclusion: The ISQ values for the buttress (Group II) is more than (Group I) which is observed in this study. Hence this study supports the buttress thread as the favourable thread pattern for the craniofacial implant.http://www.ijdr.in/article.asp?issn=0970-9290;year=2020;volume=31;issue=3;spage=403;epage=407;aulast=Ramkumarmaxillofacial implantmaxillofacial prosthesisprimary stability
collection DOAJ
language English
format Article
sources DOAJ
author Karthikeyan Ramkumar
S Sripriya
A Meenakshi
C Sabarigirinathan
C Thulasingam
spellingShingle Karthikeyan Ramkumar
S Sripriya
A Meenakshi
C Sabarigirinathan
C Thulasingam
Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis
Indian Journal of Dental Research
maxillofacial implant
maxillofacial prosthesis
primary stability
author_facet Karthikeyan Ramkumar
S Sripriya
A Meenakshi
C Sabarigirinathan
C Thulasingam
author_sort Karthikeyan Ramkumar
title Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis
title_short Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis
title_full Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis
title_fullStr Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis
title_full_unstemmed Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis
title_sort comparison of primary stability in craniofacial implant with v-shape and buttress thread design in goat skull using resonance frequency analysis
publisher Wolters Kluwer Medknow Publications
series Indian Journal of Dental Research
issn 0970-9290
1998-3603
publishDate 2020-01-01
description Background and Aims: To find out the primary stability in maxillofacial implant with two different thread designs. Methods: Two group of implants were selected for the study – Group I maxillofacial implant with V-shape thread, and Group II implant with buttress thread. The drills for placing the implant were made indigenously. Goat skull was selected for placing the implant. Group I, II implant was placed in the goat skull at five different sites to find the primary stability. The primary stability was measured using Resonance Frequency Analysis (RFA) device. The transducer was screwed to the implant and made to vibrate by magnetic pulse. The vibration was recorded as Implant Stability Quotient (ISQ). Results: The ISQ values of Group I range from 32-46 and Group II range from 57-67. The results were subjected to statistical test and found to be significant at 95% level. Conclusion: The ISQ values for the buttress (Group II) is more than (Group I) which is observed in this study. Hence this study supports the buttress thread as the favourable thread pattern for the craniofacial implant.
topic maxillofacial implant
maxillofacial prosthesis
primary stability
url http://www.ijdr.in/article.asp?issn=0970-9290;year=2020;volume=31;issue=3;spage=403;epage=407;aulast=Ramkumar
work_keys_str_mv AT karthikeyanramkumar comparisonofprimarystabilityincraniofacialimplantwithvshapeandbuttressthreaddesigningoatskullusingresonancefrequencyanalysis
AT ssripriya comparisonofprimarystabilityincraniofacialimplantwithvshapeandbuttressthreaddesigningoatskullusingresonancefrequencyanalysis
AT ameenakshi comparisonofprimarystabilityincraniofacialimplantwithvshapeandbuttressthreaddesigningoatskullusingresonancefrequencyanalysis
AT csabarigirinathan comparisonofprimarystabilityincraniofacialimplantwithvshapeandbuttressthreaddesigningoatskullusingresonancefrequencyanalysis
AT cthulasingam comparisonofprimarystabilityincraniofacialimplantwithvshapeandbuttressthreaddesigningoatskullusingresonancefrequencyanalysis
_version_ 1724961009983029248