Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis
Background and Aims: To find out the primary stability in maxillofacial implant with two different thread designs. Methods: Two group of implants were selected for the study – Group I maxillofacial implant with V-shape thread, and Group II implant with buttress thread. The drills for placing the imp...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2020-01-01
|
Series: | Indian Journal of Dental Research |
Subjects: | |
Online Access: | http://www.ijdr.in/article.asp?issn=0970-9290;year=2020;volume=31;issue=3;spage=403;epage=407;aulast=Ramkumar |
id |
doaj-febd6e9b82bf46009f7d20cc6b69655b |
---|---|
record_format |
Article |
spelling |
doaj-febd6e9b82bf46009f7d20cc6b69655b2020-11-25T02:00:22ZengWolters Kluwer Medknow PublicationsIndian Journal of Dental Research0970-92901998-36032020-01-0131340340710.4103/ijdr.IJDR_447_17Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysisKarthikeyan RamkumarS SripriyaA MeenakshiC SabarigirinathanC ThulasingamBackground and Aims: To find out the primary stability in maxillofacial implant with two different thread designs. Methods: Two group of implants were selected for the study – Group I maxillofacial implant with V-shape thread, and Group II implant with buttress thread. The drills for placing the implant were made indigenously. Goat skull was selected for placing the implant. Group I, II implant was placed in the goat skull at five different sites to find the primary stability. The primary stability was measured using Resonance Frequency Analysis (RFA) device. The transducer was screwed to the implant and made to vibrate by magnetic pulse. The vibration was recorded as Implant Stability Quotient (ISQ). Results: The ISQ values of Group I range from 32-46 and Group II range from 57-67. The results were subjected to statistical test and found to be significant at 95% level. Conclusion: The ISQ values for the buttress (Group II) is more than (Group I) which is observed in this study. Hence this study supports the buttress thread as the favourable thread pattern for the craniofacial implant.http://www.ijdr.in/article.asp?issn=0970-9290;year=2020;volume=31;issue=3;spage=403;epage=407;aulast=Ramkumarmaxillofacial implantmaxillofacial prosthesisprimary stability |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Karthikeyan Ramkumar S Sripriya A Meenakshi C Sabarigirinathan C Thulasingam |
spellingShingle |
Karthikeyan Ramkumar S Sripriya A Meenakshi C Sabarigirinathan C Thulasingam Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis Indian Journal of Dental Research maxillofacial implant maxillofacial prosthesis primary stability |
author_facet |
Karthikeyan Ramkumar S Sripriya A Meenakshi C Sabarigirinathan C Thulasingam |
author_sort |
Karthikeyan Ramkumar |
title |
Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis |
title_short |
Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis |
title_full |
Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis |
title_fullStr |
Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis |
title_full_unstemmed |
Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis |
title_sort |
comparison of primary stability in craniofacial implant with v-shape and buttress thread design in goat skull using resonance frequency analysis |
publisher |
Wolters Kluwer Medknow Publications |
series |
Indian Journal of Dental Research |
issn |
0970-9290 1998-3603 |
publishDate |
2020-01-01 |
description |
Background and Aims: To find out the primary stability in maxillofacial implant with two different thread designs. Methods: Two group of implants were selected for the study – Group I maxillofacial implant with V-shape thread, and Group II implant with buttress thread. The drills for placing the implant were made indigenously. Goat skull was selected for placing the implant. Group I, II implant was placed in the goat skull at five different sites to find the primary stability. The primary stability was measured using Resonance Frequency Analysis (RFA) device. The transducer was screwed to the implant and made to vibrate by magnetic pulse. The vibration was recorded as Implant Stability Quotient (ISQ). Results: The ISQ values of Group I range from 32-46 and Group II range from 57-67. The results were subjected to statistical test and found to be significant at 95% level. Conclusion: The ISQ values for the buttress (Group II) is more than (Group I) which is observed in this study. Hence this study supports the buttress thread as the favourable thread pattern for the craniofacial implant. |
topic |
maxillofacial implant maxillofacial prosthesis primary stability |
url |
http://www.ijdr.in/article.asp?issn=0970-9290;year=2020;volume=31;issue=3;spage=403;epage=407;aulast=Ramkumar |
work_keys_str_mv |
AT karthikeyanramkumar comparisonofprimarystabilityincraniofacialimplantwithvshapeandbuttressthreaddesigningoatskullusingresonancefrequencyanalysis AT ssripriya comparisonofprimarystabilityincraniofacialimplantwithvshapeandbuttressthreaddesigningoatskullusingresonancefrequencyanalysis AT ameenakshi comparisonofprimarystabilityincraniofacialimplantwithvshapeandbuttressthreaddesigningoatskullusingresonancefrequencyanalysis AT csabarigirinathan comparisonofprimarystabilityincraniofacialimplantwithvshapeandbuttressthreaddesigningoatskullusingresonancefrequencyanalysis AT cthulasingam comparisonofprimarystabilityincraniofacialimplantwithvshapeandbuttressthreaddesigningoatskullusingresonancefrequencyanalysis |