Evaluating the measurement interference of wet rotating-denuder–ion chromatography in measuring atmospheric HONO in a highly polluted area

<p>Due to the important contribution of nitrous acid (HONO) to OH radicals in the atmosphere, various technologies have been developed to measure HONO. Among them, wet-denuder–ion-chromatography (WD/IC) is a widely used measurement method. Here, we found interferences with HONO measurements by...

Full description

Bibliographic Details
Main Authors: Z. Xu, Y. Liu, W. Nie, P. Sun, X. Chi, A. Ding
Format: Article
Language:English
Published: Copernicus Publications 2019-12-01
Series:Atmospheric Measurement Techniques
Online Access:https://www.atmos-meas-tech.net/12/6737/2019/amt-12-6737-2019.pdf
Description
Summary:<p>Due to the important contribution of nitrous acid (HONO) to OH radicals in the atmosphere, various technologies have been developed to measure HONO. Among them, wet-denuder–ion-chromatography (WD/IC) is a widely used measurement method. Here, we found interferences with HONO measurements by WD/IC based on a comparison study of concurrent observations of HONO concentrations using a WD/IC instrument (Monitor for AeRosols and Gases in ambient Air, MARGA) and long-path absorption photometer (LOPAP) at the Station for Observing Regional Processes of the Earth System (SORPES) in eastern China. The measurement deviation of the HONO concentration with the MARGA instrument, as a typical instrument for WD/IC, is affected by two factors. One is the change in denuder pH influenced by acidic and alkaline gases in the ambient atmosphere, which can affect the absorption efficiency of HONO by the wet denuder to underestimate the HONO concentration by up to 200&thinsp;% at the lowest pH. The other is the reaction of <span class="inline-formula">NO<sub>2</sub></span> oxidizing <span class="inline-formula">SO<sub>2</sub></span> to form HONO in the denuder solution to overestimate the HONO concentration, which can be increased by to 400&thinsp;% in denuder solutions with the highest pH values due to ambient <span class="inline-formula">NH<sub>3</sub></span>. These processes are in particularly important in polluted east China, which suffers from high concentrations of <span class="inline-formula">SO<sub>2</sub></span>, <span class="inline-formula">NH<sub>3</sub></span>, and <span class="inline-formula">NO<sub>2</sub></span>. The overestimation induced by the reaction of <span class="inline-formula">NO<sub>2</sub></span> and <span class="inline-formula">SO<sub>2</sub></span> is expected to be of growing importance with the potentially increased denuder pH due to the decrease in <span class="inline-formula">SO<sub>2</sub></span>. We further established a method to correct the HONO data measured by a WD/IC instrument such as the MARGA. In case a large amount WD/IC-technique-based instruments are deployed with the main target of monitoring the water-soluble composition of PM<span class="inline-formula"><sub>2.5</sub></span>, our study can help to obtain a long-term multi-sites database of HONO to assess the role of HONO in atmospheric chemistry and air pollution in east China.</p>
ISSN:1867-1381
1867-8548