AlGaN/GaN High Electron Mobility Transistor-Based Biosensor for the Detection of C-Reactive Protein

In this paper, we propose an AlGaN/GaN high electron mobility transistor (HEMT)-based biosensor for the detection of C-reactive protein (CRP) using a null-balancing circuit. A null-balancing circuit was used to measure the output voltage of the sensor directly. The output voltage of the proposed bi...

Full description

Bibliographic Details
Main Authors: Hee Ho Lee, Myunghan Bae, Sung-Hyun Jo, Jang-Kyoo Shin, Dong Hyeok Son, Chul-Ho Won, Hyun-Min Jeong, Jung-Hee Lee, Shin-Won Kang
Format: Article
Language:English
Published: MDPI AG 2015-07-01
Series:Sensors
Subjects:
CRP
Online Access:http://www.mdpi.com/1424-8220/15/8/18416
id doaj-fe83304692c44a1bb0be225883c479b2
record_format Article
spelling doaj-fe83304692c44a1bb0be225883c479b22020-11-24T22:01:01ZengMDPI AGSensors1424-82202015-07-01158184161842610.3390/s150818416s150818416AlGaN/GaN High Electron Mobility Transistor-Based Biosensor for the Detection of C-Reactive ProteinHee Ho Lee0Myunghan Bae1Sung-Hyun Jo2Jang-Kyoo Shin3Dong Hyeok Son4Chul-Ho Won5Hyun-Min Jeong6Jung-Hee Lee7Shin-Won Kang8School of Electronics Engineering, Kyunpook National University, 80 Daehakro, Buk-gu, Daegu 702-701, KoreaSchool of Electronics Engineering, Kyunpook National University, 80 Daehakro, Buk-gu, Daegu 702-701, KoreaSchool of Electronics Engineering, Kyunpook National University, 80 Daehakro, Buk-gu, Daegu 702-701, KoreaSchool of Electronics Engineering, Kyunpook National University, 80 Daehakro, Buk-gu, Daegu 702-701, KoreaSchool of Electronics Engineering, Kyunpook National University, 80 Daehakro, Buk-gu, Daegu 702-701, KoreaSchool of Electronics Engineering, Kyunpook National University, 80 Daehakro, Buk-gu, Daegu 702-701, KoreaSchool of Electronics Engineering, Kyunpook National University, 80 Daehakro, Buk-gu, Daegu 702-701, KoreaSchool of Electronics Engineering, Kyunpook National University, 80 Daehakro, Buk-gu, Daegu 702-701, KoreaSchool of Electronics Engineering, Kyunpook National University, 80 Daehakro, Buk-gu, Daegu 702-701, KoreaIn this paper, we propose an AlGaN/GaN high electron mobility transistor (HEMT)-based biosensor for the detection of C-reactive protein (CRP) using a null-balancing circuit. A null-balancing circuit was used to measure the output voltage of the sensor directly. The output voltage of the proposed biosensor was varied by antigen-antibody interactions on the gate surface due to CRP charges. The AlGaN/GaN HFET-based biosensor with null-balancing circuit applied shows that CRP can be detected in a wide range of concentrations, varying from 10 ng/mL to 1000 ng/mL. X-ray photoelectron spectroscopy was carried out to verify the immobilization of self-assembled monolayer with Au on the gated region.http://www.mdpi.com/1424-8220/15/8/18416AlGaN/GaNHEMTCRPbiosensornull-balancing circuit
collection DOAJ
language English
format Article
sources DOAJ
author Hee Ho Lee
Myunghan Bae
Sung-Hyun Jo
Jang-Kyoo Shin
Dong Hyeok Son
Chul-Ho Won
Hyun-Min Jeong
Jung-Hee Lee
Shin-Won Kang
spellingShingle Hee Ho Lee
Myunghan Bae
Sung-Hyun Jo
Jang-Kyoo Shin
Dong Hyeok Son
Chul-Ho Won
Hyun-Min Jeong
Jung-Hee Lee
Shin-Won Kang
AlGaN/GaN High Electron Mobility Transistor-Based Biosensor for the Detection of C-Reactive Protein
Sensors
AlGaN/GaN
HEMT
CRP
biosensor
null-balancing circuit
author_facet Hee Ho Lee
Myunghan Bae
Sung-Hyun Jo
Jang-Kyoo Shin
Dong Hyeok Son
Chul-Ho Won
Hyun-Min Jeong
Jung-Hee Lee
Shin-Won Kang
author_sort Hee Ho Lee
title AlGaN/GaN High Electron Mobility Transistor-Based Biosensor for the Detection of C-Reactive Protein
title_short AlGaN/GaN High Electron Mobility Transistor-Based Biosensor for the Detection of C-Reactive Protein
title_full AlGaN/GaN High Electron Mobility Transistor-Based Biosensor for the Detection of C-Reactive Protein
title_fullStr AlGaN/GaN High Electron Mobility Transistor-Based Biosensor for the Detection of C-Reactive Protein
title_full_unstemmed AlGaN/GaN High Electron Mobility Transistor-Based Biosensor for the Detection of C-Reactive Protein
title_sort algan/gan high electron mobility transistor-based biosensor for the detection of c-reactive protein
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2015-07-01
description In this paper, we propose an AlGaN/GaN high electron mobility transistor (HEMT)-based biosensor for the detection of C-reactive protein (CRP) using a null-balancing circuit. A null-balancing circuit was used to measure the output voltage of the sensor directly. The output voltage of the proposed biosensor was varied by antigen-antibody interactions on the gate surface due to CRP charges. The AlGaN/GaN HFET-based biosensor with null-balancing circuit applied shows that CRP can be detected in a wide range of concentrations, varying from 10 ng/mL to 1000 ng/mL. X-ray photoelectron spectroscopy was carried out to verify the immobilization of self-assembled monolayer with Au on the gated region.
topic AlGaN/GaN
HEMT
CRP
biosensor
null-balancing circuit
url http://www.mdpi.com/1424-8220/15/8/18416
work_keys_str_mv AT heeholee alganganhighelectronmobilitytransistorbasedbiosensorforthedetectionofcreactiveprotein
AT myunghanbae alganganhighelectronmobilitytransistorbasedbiosensorforthedetectionofcreactiveprotein
AT sunghyunjo alganganhighelectronmobilitytransistorbasedbiosensorforthedetectionofcreactiveprotein
AT jangkyooshin alganganhighelectronmobilitytransistorbasedbiosensorforthedetectionofcreactiveprotein
AT donghyeokson alganganhighelectronmobilitytransistorbasedbiosensorforthedetectionofcreactiveprotein
AT chulhowon alganganhighelectronmobilitytransistorbasedbiosensorforthedetectionofcreactiveprotein
AT hyunminjeong alganganhighelectronmobilitytransistorbasedbiosensorforthedetectionofcreactiveprotein
AT jungheelee alganganhighelectronmobilitytransistorbasedbiosensorforthedetectionofcreactiveprotein
AT shinwonkang alganganhighelectronmobilitytransistorbasedbiosensorforthedetectionofcreactiveprotein
_version_ 1725842212277714944