Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities

The prevalence of Legionella pneumophilia in water systems of residential facilities in Kuwait was performed during the period from November 2007 to November 2011. A total of 204 water samples collected from faucets and showerheads in bathrooms (n = 82), taps in kitchens (n = 51), and water tanks (n...

Full description

Bibliographic Details
Main Authors: Qadreyah A. Al-Matawah, Sameer F. Al-Zenki, Jafer A. Qasem, Tahani E. Al-Waalan, Ahmed H. Ben Heji
Format: Article
Language:English
Published: Hindawi Limited 2012-01-01
Series:Journal of Pathogens
Online Access:http://dx.doi.org/10.1155/2012/138389
id doaj-fdf80e23cc784b60aa37141eb8931ed8
record_format Article
spelling doaj-fdf80e23cc784b60aa37141eb8931ed82020-11-24T23:01:33ZengHindawi LimitedJournal of Pathogens2090-30572090-30652012-01-01201210.1155/2012/138389138389Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential FacilitiesQadreyah A. Al-Matawah0Sameer F. Al-Zenki1Jafer A. Qasem2Tahani E. Al-Waalan3Ahmed H. Ben Heji4Biotechnology Department, Kuwait Institute for Scientific Research, Safat 13109, KuwaitBiotechnology Department, Kuwait Institute for Scientific Research, Safat 13109, KuwaitDepartment of Applied Medical Sciences, College of Health Sciences, The Public Authority for Applied Education and Training, Safat 13092, KuwaitBiotechnology Department, Kuwait Institute for Scientific Research, Safat 13109, KuwaitBiotechnology Department, Kuwait Institute for Scientific Research, Safat 13109, KuwaitThe prevalence of Legionella pneumophilia in water systems of residential facilities in Kuwait was performed during the period from November 2007 to November 2011. A total of 204 water samples collected from faucets and showerheads in bathrooms (n = 82), taps in kitchens (n = 51), and water tanks (n = 71), from different locations of residential facilities in Kuwait were screened for Legionella pneumophila by the standard culture method and by real time polymerase chain reaction (RT-PCR). Out of the 204 samples, 89 (43.6%) samples were positive for Legionella spp., 48 (23.5%) samples were detected by the standard culture method, and 85 (41.7%) were detected by RT-PCR. Of the culture positive Legionella samples, counts ranged between 10 to 2250 CFU/L. Serological typing of 48 Legionella isolates revealed that 6 (12.5%) of these isolates belonged to Legionella pneumophila serogroup 1, 37 (77.1%) isolates to Legionella pneumophila serogroup 3, and 1 isolate each (2.1%) belonged to serogroups 4, 7, and 10. The minimum inhibitory concentration (MICs) of the 46 environmental L. pneumophila isolates against the 10 antimicrobials commonly used for Legionella infection treatments were determined. Rifampicin was found to be the most active against L. pneumophila serogroups isolates in vitro.http://dx.doi.org/10.1155/2012/138389
collection DOAJ
language English
format Article
sources DOAJ
author Qadreyah A. Al-Matawah
Sameer F. Al-Zenki
Jafer A. Qasem
Tahani E. Al-Waalan
Ahmed H. Ben Heji
spellingShingle Qadreyah A. Al-Matawah
Sameer F. Al-Zenki
Jafer A. Qasem
Tahani E. Al-Waalan
Ahmed H. Ben Heji
Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities
Journal of Pathogens
author_facet Qadreyah A. Al-Matawah
Sameer F. Al-Zenki
Jafer A. Qasem
Tahani E. Al-Waalan
Ahmed H. Ben Heji
author_sort Qadreyah A. Al-Matawah
title Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities
title_short Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities
title_full Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities
title_fullStr Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities
title_full_unstemmed Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities
title_sort detection and quantification of legionella pneumophila from water systems in kuwait residential facilities
publisher Hindawi Limited
series Journal of Pathogens
issn 2090-3057
2090-3065
publishDate 2012-01-01
description The prevalence of Legionella pneumophilia in water systems of residential facilities in Kuwait was performed during the period from November 2007 to November 2011. A total of 204 water samples collected from faucets and showerheads in bathrooms (n = 82), taps in kitchens (n = 51), and water tanks (n = 71), from different locations of residential facilities in Kuwait were screened for Legionella pneumophila by the standard culture method and by real time polymerase chain reaction (RT-PCR). Out of the 204 samples, 89 (43.6%) samples were positive for Legionella spp., 48 (23.5%) samples were detected by the standard culture method, and 85 (41.7%) were detected by RT-PCR. Of the culture positive Legionella samples, counts ranged between 10 to 2250 CFU/L. Serological typing of 48 Legionella isolates revealed that 6 (12.5%) of these isolates belonged to Legionella pneumophila serogroup 1, 37 (77.1%) isolates to Legionella pneumophila serogroup 3, and 1 isolate each (2.1%) belonged to serogroups 4, 7, and 10. The minimum inhibitory concentration (MICs) of the 46 environmental L. pneumophila isolates against the 10 antimicrobials commonly used for Legionella infection treatments were determined. Rifampicin was found to be the most active against L. pneumophila serogroups isolates in vitro.
url http://dx.doi.org/10.1155/2012/138389
work_keys_str_mv AT qadreyahaalmatawah detectionandquantificationoflegionellapneumophilafromwatersystemsinkuwaitresidentialfacilities
AT sameerfalzenki detectionandquantificationoflegionellapneumophilafromwatersystemsinkuwaitresidentialfacilities
AT jaferaqasem detectionandquantificationoflegionellapneumophilafromwatersystemsinkuwaitresidentialfacilities
AT tahaniealwaalan detectionandquantificationoflegionellapneumophilafromwatersystemsinkuwaitresidentialfacilities
AT ahmedhbenheji detectionandquantificationoflegionellapneumophilafromwatersystemsinkuwaitresidentialfacilities
_version_ 1725639171360423936