Spectroscopic analysis of PMMA/PVC blends containing CoCl2
Composites of polymethyl methacrylate (PMMA) and polyvinyl chloride (PVC) polymer blend containing different concentrations (⩽10 wt.) of cobalt chloride (CoCl2) were prepared by casting techniques. The changes of the structural, spectroscopic, optical and thermal parameters of the samples are studie...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2015-01-01
|
Series: | Results in Physics |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2211379715000650 |
id |
doaj-fdc27874a55b42439bfba0da9eda44a9 |
---|---|
record_format |
Article |
spelling |
doaj-fdc27874a55b42439bfba0da9eda44a92020-11-24T22:28:52ZengElsevierResults in Physics2211-37972015-01-015C33133610.1016/j.rinp.2015.11.003Spectroscopic analysis of PMMA/PVC blends containing CoCl2N.S. AlghunaimComposites of polymethyl methacrylate (PMMA) and polyvinyl chloride (PVC) polymer blend containing different concentrations (⩽10 wt.) of cobalt chloride (CoCl2) were prepared by casting techniques. The changes of the structural, spectroscopic, optical and thermal parameters of the samples are studied using different tools. FT-IR spectroscopy confirmed the complexation between the blends and Co+2-ions. The decrease or increase of IR band intensity with some shifts of other bands suggests an interaction and compatibility between PMMA/PVC blends with CoCl2 take place. The Ultra violet and visible (UV/Vis) spectra indicated that the presence of band gap energy depends on increasing of CoCl2 contents. The absorption intensity of the samples doped with CoCl2 becomes faint lower than the pure blend. The values of energy gap for direct and indirect transition decreases with the increase of CoCl2 due to the presence of charge transfer between PMMA/PVC and CoCl2. The thermogravimetric analysis (TGA) curves for all the samples have the same behavior and more steps of decomposition were observed. The reduction of mass loss for samples containing CoCl2 compared to the pure blend was observed and it was attributed to crosslink formation between the blend and CoCl2.http://www.sciencedirect.com/science/article/pii/S2211379715000650Polymer blendX-rayUV–VisFT-IRThermal stability |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
N.S. Alghunaim |
spellingShingle |
N.S. Alghunaim Spectroscopic analysis of PMMA/PVC blends containing CoCl2 Results in Physics Polymer blend X-ray UV–Vis FT-IR Thermal stability |
author_facet |
N.S. Alghunaim |
author_sort |
N.S. Alghunaim |
title |
Spectroscopic analysis of PMMA/PVC blends containing CoCl2 |
title_short |
Spectroscopic analysis of PMMA/PVC blends containing CoCl2 |
title_full |
Spectroscopic analysis of PMMA/PVC blends containing CoCl2 |
title_fullStr |
Spectroscopic analysis of PMMA/PVC blends containing CoCl2 |
title_full_unstemmed |
Spectroscopic analysis of PMMA/PVC blends containing CoCl2 |
title_sort |
spectroscopic analysis of pmma/pvc blends containing cocl2 |
publisher |
Elsevier |
series |
Results in Physics |
issn |
2211-3797 |
publishDate |
2015-01-01 |
description |
Composites of polymethyl methacrylate (PMMA) and polyvinyl chloride (PVC) polymer blend containing different concentrations (⩽10 wt.) of cobalt chloride (CoCl2) were prepared by casting techniques. The changes of the structural, spectroscopic, optical and thermal parameters of the samples are studied using different tools. FT-IR spectroscopy confirmed the complexation between the blends and Co+2-ions. The decrease or increase of IR band intensity with some shifts of other bands suggests an interaction and compatibility between PMMA/PVC blends with CoCl2 take place. The Ultra violet and visible (UV/Vis) spectra indicated that the presence of band gap energy depends on increasing of CoCl2 contents. The absorption intensity of the samples doped with CoCl2 becomes faint lower than the pure blend. The values of energy gap for direct and indirect transition decreases with the increase of CoCl2 due to the presence of charge transfer between PMMA/PVC and CoCl2. The thermogravimetric analysis (TGA) curves for all the samples have the same behavior and more steps of decomposition were observed. The reduction of mass loss for samples containing CoCl2 compared to the pure blend was observed and it was attributed to crosslink formation between the blend and CoCl2. |
topic |
Polymer blend X-ray UV–Vis FT-IR Thermal stability |
url |
http://www.sciencedirect.com/science/article/pii/S2211379715000650 |
work_keys_str_mv |
AT nsalghunaim spectroscopicanalysisofpmmapvcblendscontainingcocl2 |
_version_ |
1725745958030934016 |