METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA
The possibility of detecting some organic compounds directly in a petroleum/water interface was described. Aqueous phase was composed by 1 x 10-3 mol L-1 NaCl solution and the oil phase was carried out using crude oil forming an oil/water interface. Carbon based screen-printed electrodes was used in...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Química
|
Series: | Química Nova |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422019000100095&lng=en&tlng=en |
id |
doaj-fd61046313784715a7b4e93e83b24389 |
---|---|
record_format |
Article |
spelling |
doaj-fd61046313784715a7b4e93e83b243892020-11-25T00:34:54ZengSociedade Brasileira de QuímicaQuímica Nova1678-7064421959810.21577/0100-4042.20170298S0100-40422019000100095METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUARoberval A. SilvaRejane M. P. SilvaKeyla T. SantosTatiana S. AraujoAlexandre C. AlcântaraHugo B. SuffrediniThe possibility of detecting some organic compounds directly in a petroleum/water interface was described. Aqueous phase was composed by 1 x 10-3 mol L-1 NaCl solution and the oil phase was carried out using crude oil forming an oil/water interface. Carbon based screen-printed electrodes was used in conjunction with square-wave voltammetry technique, constituting the main tools of this technical note. Petroleum was contaminated with phenol, naphthalene and cyclohexane. The oxidation potentials for these three molecules were 0,72, 0,81 and 0,87 V vs. Ag, respectively. Phenol was chosen to study the stability of currents during the process. After 15 minutes, the currents of this process were stable. Although the formation of a passivation film, the qualitative detection of the molecules was possible. Finally, the main advantage of this methodology is the possibility of detecting contaminants in oil without the necessity of complicated pre-treatment steps.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422019000100095&lng=en&tlng=enoil/water interfacespetroleumqualitative detectionscreen-printed electrode |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Roberval A. Silva Rejane M. P. Silva Keyla T. Santos Tatiana S. Araujo Alexandre C. Alcântara Hugo B. Suffredini |
spellingShingle |
Roberval A. Silva Rejane M. P. Silva Keyla T. Santos Tatiana S. Araujo Alexandre C. Alcântara Hugo B. Suffredini METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA Química Nova oil/water interfaces petroleum qualitative detection screen-printed electrode |
author_facet |
Roberval A. Silva Rejane M. P. Silva Keyla T. Santos Tatiana S. Araujo Alexandre C. Alcântara Hugo B. Suffredini |
author_sort |
Roberval A. Silva |
title |
METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA |
title_short |
METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA |
title_full |
METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA |
title_fullStr |
METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA |
title_full_unstemmed |
METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA |
title_sort |
metodologia para detecção eletroquímica qualitativa de compostos orgânicos em interfaces petróleo/água |
publisher |
Sociedade Brasileira de Química |
series |
Química Nova |
issn |
1678-7064 |
description |
The possibility of detecting some organic compounds directly in a petroleum/water interface was described. Aqueous phase was composed by 1 x 10-3 mol L-1 NaCl solution and the oil phase was carried out using crude oil forming an oil/water interface. Carbon based screen-printed electrodes was used in conjunction with square-wave voltammetry technique, constituting the main tools of this technical note. Petroleum was contaminated with phenol, naphthalene and cyclohexane. The oxidation potentials for these three molecules were 0,72, 0,81 and 0,87 V vs. Ag, respectively. Phenol was chosen to study the stability of currents during the process. After 15 minutes, the currents of this process were stable. Although the formation of a passivation film, the qualitative detection of the molecules was possible. Finally, the main advantage of this methodology is the possibility of detecting contaminants in oil without the necessity of complicated pre-treatment steps. |
topic |
oil/water interfaces petroleum qualitative detection screen-printed electrode |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422019000100095&lng=en&tlng=en |
work_keys_str_mv |
AT robervalasilva metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua AT rejanempsilva metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua AT keylatsantos metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua AT tatianasaraujo metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua AT alexandrecalcantara metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua AT hugobsuffredini metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua |
_version_ |
1725311492968939520 |