METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA

The possibility of detecting some organic compounds directly in a petroleum/water interface was described. Aqueous phase was composed by 1 x 10-3 mol L-1 NaCl solution and the oil phase was carried out using crude oil forming an oil/water interface. Carbon based screen-printed electrodes was used in...

Full description

Bibliographic Details
Main Authors: Roberval A. Silva, Rejane M. P. Silva, Keyla T. Santos, Tatiana S. Araujo, Alexandre C. Alcântara, Hugo B. Suffredini
Format: Article
Language:English
Published: Sociedade Brasileira de Química
Series:Química Nova
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422019000100095&lng=en&tlng=en
id doaj-fd61046313784715a7b4e93e83b24389
record_format Article
spelling doaj-fd61046313784715a7b4e93e83b243892020-11-25T00:34:54ZengSociedade Brasileira de QuímicaQuímica Nova1678-7064421959810.21577/0100-4042.20170298S0100-40422019000100095METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUARoberval A. SilvaRejane M. P. SilvaKeyla T. SantosTatiana S. AraujoAlexandre C. AlcântaraHugo B. SuffrediniThe possibility of detecting some organic compounds directly in a petroleum/water interface was described. Aqueous phase was composed by 1 x 10-3 mol L-1 NaCl solution and the oil phase was carried out using crude oil forming an oil/water interface. Carbon based screen-printed electrodes was used in conjunction with square-wave voltammetry technique, constituting the main tools of this technical note. Petroleum was contaminated with phenol, naphthalene and cyclohexane. The oxidation potentials for these three molecules were 0,72, 0,81 and 0,87 V vs. Ag, respectively. Phenol was chosen to study the stability of currents during the process. After 15 minutes, the currents of this process were stable. Although the formation of a passivation film, the qualitative detection of the molecules was possible. Finally, the main advantage of this methodology is the possibility of detecting contaminants in oil without the necessity of complicated pre-treatment steps.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422019000100095&lng=en&tlng=enoil/water interfacespetroleumqualitative detectionscreen-printed electrode
collection DOAJ
language English
format Article
sources DOAJ
author Roberval A. Silva
Rejane M. P. Silva
Keyla T. Santos
Tatiana S. Araujo
Alexandre C. Alcântara
Hugo B. Suffredini
spellingShingle Roberval A. Silva
Rejane M. P. Silva
Keyla T. Santos
Tatiana S. Araujo
Alexandre C. Alcântara
Hugo B. Suffredini
METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA
Química Nova
oil/water interfaces
petroleum
qualitative detection
screen-printed electrode
author_facet Roberval A. Silva
Rejane M. P. Silva
Keyla T. Santos
Tatiana S. Araujo
Alexandre C. Alcântara
Hugo B. Suffredini
author_sort Roberval A. Silva
title METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA
title_short METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA
title_full METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA
title_fullStr METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA
title_full_unstemmed METODOLOGIA PARA DETECÇÃO ELETROQUÍMICA QUALITATIVA DE COMPOSTOS ORGÂNICOS EM INTERFACES PETRÓLEO/ÁGUA
title_sort metodologia para detecção eletroquímica qualitativa de compostos orgânicos em interfaces petróleo/água
publisher Sociedade Brasileira de Química
series Química Nova
issn 1678-7064
description The possibility of detecting some organic compounds directly in a petroleum/water interface was described. Aqueous phase was composed by 1 x 10-3 mol L-1 NaCl solution and the oil phase was carried out using crude oil forming an oil/water interface. Carbon based screen-printed electrodes was used in conjunction with square-wave voltammetry technique, constituting the main tools of this technical note. Petroleum was contaminated with phenol, naphthalene and cyclohexane. The oxidation potentials for these three molecules were 0,72, 0,81 and 0,87 V vs. Ag, respectively. Phenol was chosen to study the stability of currents during the process. After 15 minutes, the currents of this process were stable. Although the formation of a passivation film, the qualitative detection of the molecules was possible. Finally, the main advantage of this methodology is the possibility of detecting contaminants in oil without the necessity of complicated pre-treatment steps.
topic oil/water interfaces
petroleum
qualitative detection
screen-printed electrode
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422019000100095&lng=en&tlng=en
work_keys_str_mv AT robervalasilva metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua
AT rejanempsilva metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua
AT keylatsantos metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua
AT tatianasaraujo metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua
AT alexandrecalcantara metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua
AT hugobsuffredini metodologiaparadeteccaoeletroquimicaqualitativadecompostosorganicoseminterfacespetroleoagua
_version_ 1725311492968939520