Research and Application of Generator Protection Based on Fiber Optical Current Transformer
This paper introduces the basic principle of fibre optical current transformer (FOCT), and explains the advantages of FOCT compared with electromagnetic current transformer (CT). FOCT can be wound around the primary conductor in any shape, has high harmonic accuracy and doesn't suffer from satu...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2020-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/9174845/ |
id |
doaj-fd2d61bee14b45418b5a03be6debad93 |
---|---|
record_format |
Article |
spelling |
doaj-fd2d61bee14b45418b5a03be6debad932021-03-30T03:58:45ZengIEEEIEEE Access2169-35362020-01-01817240517241110.1109/ACCESS.2020.30187349174845Research and Application of Generator Protection Based on Fiber Optical Current TransformerJun Chen0Qingshan Xu1https://orcid.org/0000-0002-4526-9973Kai Wang2https://orcid.org/0000-0002-3972-2081School of Electrical Engineering, Southeast University, Nanjing, ChinaSchool of Electrical Engineering, Southeast University, Nanjing, ChinaNR Electric Company Ltd., Nanjing, ChinaThis paper introduces the basic principle of fibre optical current transformer (FOCT), and explains the advantages of FOCT compared with electromagnetic current transformer (CT). FOCT can be wound around the primary conductor in any shape, has high harmonic accuracy and doesn't suffer from saturation, thus a good solution for generator relay protection. As a common electrical fault within large generators, the inter-turn short circuit in field windings (ISCFW) is likely to cause earth faults between the field winding and the rotor body and magnetization of the main shaft without timely intervention. Steady-state unbalanced currents of even orders and fractional orders related with pole pairs inside phase windings are required to monitor the ISCFW. The inter-turn fault of stator windings may rapidly develop into a phase to phase fault, which seriously threatens the safety of the unit. Split-phase transverse differential current reflects the steady-state current imbalance inside the stator winding. Nevertheless, for most steam turbine generators and some hydro turbine generators, it is unable to obtain phase-segregated transverse differential current due to impossibility of installing branch current transformer in the narrow space inside the generator. However, FOCT which uses fibre optic cable as a sensor is installable within limited space to measure the current of each group of winding branches of each phase. FOCT furthers phase-segregated transverse differential protection, partial differential protection and online monitoring of the ISCFW, thus optimizing the generators protection scheme. In addition, operating speed and sensitivity of generator differential protection are improved based on the reliable measurement from FOCT. The proposed scheme is verified by an application on a 300MW generator at a pump-storage power plant. This is the first attempt of applying FOCT to the relay protection of generator set, which provides reference for further development and application of FOCT in power plant.https://ieeexplore.ieee.org/document/9174845/Fibre optical current transformer (FOCT)phase-segregated transverse differential protectionstator winding inter-turn short circuitrotor winding inter-turn short circuit |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jun Chen Qingshan Xu Kai Wang |
spellingShingle |
Jun Chen Qingshan Xu Kai Wang Research and Application of Generator Protection Based on Fiber Optical Current Transformer IEEE Access Fibre optical current transformer (FOCT) phase-segregated transverse differential protection stator winding inter-turn short circuit rotor winding inter-turn short circuit |
author_facet |
Jun Chen Qingshan Xu Kai Wang |
author_sort |
Jun Chen |
title |
Research and Application of Generator Protection Based on Fiber Optical Current Transformer |
title_short |
Research and Application of Generator Protection Based on Fiber Optical Current Transformer |
title_full |
Research and Application of Generator Protection Based on Fiber Optical Current Transformer |
title_fullStr |
Research and Application of Generator Protection Based on Fiber Optical Current Transformer |
title_full_unstemmed |
Research and Application of Generator Protection Based on Fiber Optical Current Transformer |
title_sort |
research and application of generator protection based on fiber optical current transformer |
publisher |
IEEE |
series |
IEEE Access |
issn |
2169-3536 |
publishDate |
2020-01-01 |
description |
This paper introduces the basic principle of fibre optical current transformer (FOCT), and explains the advantages of FOCT compared with electromagnetic current transformer (CT). FOCT can be wound around the primary conductor in any shape, has high harmonic accuracy and doesn't suffer from saturation, thus a good solution for generator relay protection. As a common electrical fault within large generators, the inter-turn short circuit in field windings (ISCFW) is likely to cause earth faults between the field winding and the rotor body and magnetization of the main shaft without timely intervention. Steady-state unbalanced currents of even orders and fractional orders related with pole pairs inside phase windings are required to monitor the ISCFW. The inter-turn fault of stator windings may rapidly develop into a phase to phase fault, which seriously threatens the safety of the unit. Split-phase transverse differential current reflects the steady-state current imbalance inside the stator winding. Nevertheless, for most steam turbine generators and some hydro turbine generators, it is unable to obtain phase-segregated transverse differential current due to impossibility of installing branch current transformer in the narrow space inside the generator. However, FOCT which uses fibre optic cable as a sensor is installable within limited space to measure the current of each group of winding branches of each phase. FOCT furthers phase-segregated transverse differential protection, partial differential protection and online monitoring of the ISCFW, thus optimizing the generators protection scheme. In addition, operating speed and sensitivity of generator differential protection are improved based on the reliable measurement from FOCT. The proposed scheme is verified by an application on a 300MW generator at a pump-storage power plant. This is the first attempt of applying FOCT to the relay protection of generator set, which provides reference for further development and application of FOCT in power plant. |
topic |
Fibre optical current transformer (FOCT) phase-segregated transverse differential protection stator winding inter-turn short circuit rotor winding inter-turn short circuit |
url |
https://ieeexplore.ieee.org/document/9174845/ |
work_keys_str_mv |
AT junchen researchandapplicationofgeneratorprotectionbasedonfiberopticalcurrenttransformer AT qingshanxu researchandapplicationofgeneratorprotectionbasedonfiberopticalcurrenttransformer AT kaiwang researchandapplicationofgeneratorprotectionbasedonfiberopticalcurrenttransformer |
_version_ |
1724182581368324096 |