Research and Application of Generator Protection Based on Fiber Optical Current Transformer

This paper introduces the basic principle of fibre optical current transformer (FOCT), and explains the advantages of FOCT compared with electromagnetic current transformer (CT). FOCT can be wound around the primary conductor in any shape, has high harmonic accuracy and doesn't suffer from satu...

Full description

Bibliographic Details
Main Authors: Jun Chen, Qingshan Xu, Kai Wang
Format: Article
Language:English
Published: IEEE 2020-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9174845/
id doaj-fd2d61bee14b45418b5a03be6debad93
record_format Article
spelling doaj-fd2d61bee14b45418b5a03be6debad932021-03-30T03:58:45ZengIEEEIEEE Access2169-35362020-01-01817240517241110.1109/ACCESS.2020.30187349174845Research and Application of Generator Protection Based on Fiber Optical Current TransformerJun Chen0Qingshan Xu1https://orcid.org/0000-0002-4526-9973Kai Wang2https://orcid.org/0000-0002-3972-2081School of Electrical Engineering, Southeast University, Nanjing, ChinaSchool of Electrical Engineering, Southeast University, Nanjing, ChinaNR Electric Company Ltd., Nanjing, ChinaThis paper introduces the basic principle of fibre optical current transformer (FOCT), and explains the advantages of FOCT compared with electromagnetic current transformer (CT). FOCT can be wound around the primary conductor in any shape, has high harmonic accuracy and doesn't suffer from saturation, thus a good solution for generator relay protection. As a common electrical fault within large generators, the inter-turn short circuit in field windings (ISCFW) is likely to cause earth faults between the field winding and the rotor body and magnetization of the main shaft without timely intervention. Steady-state unbalanced currents of even orders and fractional orders related with pole pairs inside phase windings are required to monitor the ISCFW. The inter-turn fault of stator windings may rapidly develop into a phase to phase fault, which seriously threatens the safety of the unit. Split-phase transverse differential current reflects the steady-state current imbalance inside the stator winding. Nevertheless, for most steam turbine generators and some hydro turbine generators, it is unable to obtain phase-segregated transverse differential current due to impossibility of installing branch current transformer in the narrow space inside the generator. However, FOCT which uses fibre optic cable as a sensor is installable within limited space to measure the current of each group of winding branches of each phase. FOCT furthers phase-segregated transverse differential protection, partial differential protection and online monitoring of the ISCFW, thus optimizing the generators protection scheme. In addition, operating speed and sensitivity of generator differential protection are improved based on the reliable measurement from FOCT. The proposed scheme is verified by an application on a 300MW generator at a pump-storage power plant. This is the first attempt of applying FOCT to the relay protection of generator set, which provides reference for further development and application of FOCT in power plant.https://ieeexplore.ieee.org/document/9174845/Fibre optical current transformer (FOCT)phase-segregated transverse differential protectionstator winding inter-turn short circuitrotor winding inter-turn short circuit
collection DOAJ
language English
format Article
sources DOAJ
author Jun Chen
Qingshan Xu
Kai Wang
spellingShingle Jun Chen
Qingshan Xu
Kai Wang
Research and Application of Generator Protection Based on Fiber Optical Current Transformer
IEEE Access
Fibre optical current transformer (FOCT)
phase-segregated transverse differential protection
stator winding inter-turn short circuit
rotor winding inter-turn short circuit
author_facet Jun Chen
Qingshan Xu
Kai Wang
author_sort Jun Chen
title Research and Application of Generator Protection Based on Fiber Optical Current Transformer
title_short Research and Application of Generator Protection Based on Fiber Optical Current Transformer
title_full Research and Application of Generator Protection Based on Fiber Optical Current Transformer
title_fullStr Research and Application of Generator Protection Based on Fiber Optical Current Transformer
title_full_unstemmed Research and Application of Generator Protection Based on Fiber Optical Current Transformer
title_sort research and application of generator protection based on fiber optical current transformer
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2020-01-01
description This paper introduces the basic principle of fibre optical current transformer (FOCT), and explains the advantages of FOCT compared with electromagnetic current transformer (CT). FOCT can be wound around the primary conductor in any shape, has high harmonic accuracy and doesn't suffer from saturation, thus a good solution for generator relay protection. As a common electrical fault within large generators, the inter-turn short circuit in field windings (ISCFW) is likely to cause earth faults between the field winding and the rotor body and magnetization of the main shaft without timely intervention. Steady-state unbalanced currents of even orders and fractional orders related with pole pairs inside phase windings are required to monitor the ISCFW. The inter-turn fault of stator windings may rapidly develop into a phase to phase fault, which seriously threatens the safety of the unit. Split-phase transverse differential current reflects the steady-state current imbalance inside the stator winding. Nevertheless, for most steam turbine generators and some hydro turbine generators, it is unable to obtain phase-segregated transverse differential current due to impossibility of installing branch current transformer in the narrow space inside the generator. However, FOCT which uses fibre optic cable as a sensor is installable within limited space to measure the current of each group of winding branches of each phase. FOCT furthers phase-segregated transverse differential protection, partial differential protection and online monitoring of the ISCFW, thus optimizing the generators protection scheme. In addition, operating speed and sensitivity of generator differential protection are improved based on the reliable measurement from FOCT. The proposed scheme is verified by an application on a 300MW generator at a pump-storage power plant. This is the first attempt of applying FOCT to the relay protection of generator set, which provides reference for further development and application of FOCT in power plant.
topic Fibre optical current transformer (FOCT)
phase-segregated transverse differential protection
stator winding inter-turn short circuit
rotor winding inter-turn short circuit
url https://ieeexplore.ieee.org/document/9174845/
work_keys_str_mv AT junchen researchandapplicationofgeneratorprotectionbasedonfiberopticalcurrenttransformer
AT qingshanxu researchandapplicationofgeneratorprotectionbasedonfiberopticalcurrenttransformer
AT kaiwang researchandapplicationofgeneratorprotectionbasedonfiberopticalcurrenttransformer
_version_ 1724182581368324096