Finite Control Set–Model Predictive Control with Modulation to Mitigate Harmonic Component in Output Current for a Grid-Connected Inverter under Distorted Grid Conditions

This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. In terms of performance, it is important for a grid-connected inverter to maintain the harmonic contents of inverter output currents below the specified limit even when...

Full description

Bibliographic Details
Main Authors: Tien Hai Nguyen, Kyeong-Hwa Kim
Format: Article
Language:English
Published: MDPI AG 2017-07-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/10/7/907
id doaj-fbc5d59b3a9c4b89b68028c7d3472647
record_format Article
spelling doaj-fbc5d59b3a9c4b89b68028c7d34726472020-11-24T21:23:14ZengMDPI AGEnergies1996-10732017-07-0110790710.3390/en10070907en10070907Finite Control Set–Model Predictive Control with Modulation to Mitigate Harmonic Component in Output Current for a Grid-Connected Inverter under Distorted Grid ConditionsTien Hai Nguyen0Kyeong-Hwa Kim1Department of Electrical and Information Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, KoreaDepartment of Electrical and Information Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, KoreaThis paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. In terms of performance, it is important for a grid-connected inverter to maintain the harmonic contents of inverter output currents below the specified limit even when the grid is subject to harmonic distortion. To address this problem, this paper proposes a modulated finite control set–model predictive control (FCS-MPC) scheme, which effectively mitigates the harmonic components in output current of a grid-connected inverter. In the proposed scheme, the system behavior in the future is predicted from the system model in the discrete-time domain. Then, the cost function is selected based on the control objective of system. This cost function is minimized during the optimization process to determine the control signals that minimize the cost function. In addition, since the proposed scheme requires pure sinusoidal reference currents in the stationary frame to work successfully, the moving average filter (MAF) is employed to enhance the performance of the traditional phase lock loop (PLL). Due to the control performance of the FCS-MPC scheme as well as the harmonic disturbance rejection capability of the MAF-PLL, the proposed scheme is able to suppress the harmonic distortion even in the presence of distorted grid condition, while retaining fast transient response. Comparative simulation results of different controllers verify the effectiveness of the proposed control scheme in compensating the harmonic disturbance. To validate the practical feasibility of the proposed scheme, the whole control algorithm is implemented on a 32-bit floating-point digital signal processor (DSP) TMS320F28335 to control a 2 kW three-phase grid-connected inverter. As a result, the proposed scheme is a promising approach toward improving the current quality of a grid-connected inverter under distorted grid conditions.https://www.mdpi.com/1996-1073/10/7/907current controldistorted grid conditionsDSP TMS320F28335grid-connected inverterharmonic mitigationmodel predictive controlpower quality
collection DOAJ
language English
format Article
sources DOAJ
author Tien Hai Nguyen
Kyeong-Hwa Kim
spellingShingle Tien Hai Nguyen
Kyeong-Hwa Kim
Finite Control Set–Model Predictive Control with Modulation to Mitigate Harmonic Component in Output Current for a Grid-Connected Inverter under Distorted Grid Conditions
Energies
current control
distorted grid conditions
DSP TMS320F28335
grid-connected inverter
harmonic mitigation
model predictive control
power quality
author_facet Tien Hai Nguyen
Kyeong-Hwa Kim
author_sort Tien Hai Nguyen
title Finite Control Set–Model Predictive Control with Modulation to Mitigate Harmonic Component in Output Current for a Grid-Connected Inverter under Distorted Grid Conditions
title_short Finite Control Set–Model Predictive Control with Modulation to Mitigate Harmonic Component in Output Current for a Grid-Connected Inverter under Distorted Grid Conditions
title_full Finite Control Set–Model Predictive Control with Modulation to Mitigate Harmonic Component in Output Current for a Grid-Connected Inverter under Distorted Grid Conditions
title_fullStr Finite Control Set–Model Predictive Control with Modulation to Mitigate Harmonic Component in Output Current for a Grid-Connected Inverter under Distorted Grid Conditions
title_full_unstemmed Finite Control Set–Model Predictive Control with Modulation to Mitigate Harmonic Component in Output Current for a Grid-Connected Inverter under Distorted Grid Conditions
title_sort finite control set–model predictive control with modulation to mitigate harmonic component in output current for a grid-connected inverter under distorted grid conditions
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2017-07-01
description This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. In terms of performance, it is important for a grid-connected inverter to maintain the harmonic contents of inverter output currents below the specified limit even when the grid is subject to harmonic distortion. To address this problem, this paper proposes a modulated finite control set–model predictive control (FCS-MPC) scheme, which effectively mitigates the harmonic components in output current of a grid-connected inverter. In the proposed scheme, the system behavior in the future is predicted from the system model in the discrete-time domain. Then, the cost function is selected based on the control objective of system. This cost function is minimized during the optimization process to determine the control signals that minimize the cost function. In addition, since the proposed scheme requires pure sinusoidal reference currents in the stationary frame to work successfully, the moving average filter (MAF) is employed to enhance the performance of the traditional phase lock loop (PLL). Due to the control performance of the FCS-MPC scheme as well as the harmonic disturbance rejection capability of the MAF-PLL, the proposed scheme is able to suppress the harmonic distortion even in the presence of distorted grid condition, while retaining fast transient response. Comparative simulation results of different controllers verify the effectiveness of the proposed control scheme in compensating the harmonic disturbance. To validate the practical feasibility of the proposed scheme, the whole control algorithm is implemented on a 32-bit floating-point digital signal processor (DSP) TMS320F28335 to control a 2 kW three-phase grid-connected inverter. As a result, the proposed scheme is a promising approach toward improving the current quality of a grid-connected inverter under distorted grid conditions.
topic current control
distorted grid conditions
DSP TMS320F28335
grid-connected inverter
harmonic mitigation
model predictive control
power quality
url https://www.mdpi.com/1996-1073/10/7/907
work_keys_str_mv AT tienhainguyen finitecontrolsetmodelpredictivecontrolwithmodulationtomitigateharmoniccomponentinoutputcurrentforagridconnectedinverterunderdistortedgridconditions
AT kyeonghwakim finitecontrolsetmodelpredictivecontrolwithmodulationtomitigateharmoniccomponentinoutputcurrentforagridconnectedinverterunderdistortedgridconditions
_version_ 1725992794619641856