The sound of operation and the acoustic attenuation of the Ohmeda Medical Giraffe OmniBed TM

The neonatal intensive care unit (NICU) is an environment that provides premature and fragile infants with health provisions needed to make a complete recovery. Premature infants are often born before their auditory systems have had an opportunity to fully mature. Research has shown that the ambient...

Full description

Bibliographic Details
Main Authors: Stephanie M Wubben, Paul M Brueggeman, Dennis C Stevens, Carol C Helseth, Kristen Blaschke
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2011-01-01
Series:Noise and Health
Subjects:
dBA
Online Access:http://www.noiseandhealth.org/article.asp?issn=1463-1741;year=2011;volume=13;issue=50;spage=37;epage=44;aulast=Wubben
id doaj-fb8dd7b3e307458695bbf2fa325b9f8e
record_format Article
spelling doaj-fb8dd7b3e307458695bbf2fa325b9f8e2020-11-25T00:15:16ZengWolters Kluwer Medknow PublicationsNoise and Health1463-17411998-40302011-01-011350374410.4103/1463-1741.73999The sound of operation and the acoustic attenuation of the Ohmeda Medical Giraffe OmniBed TMStephanie M WubbenPaul M BrueggemanDennis C StevensCarol C HelsethKristen BlaschkeThe neonatal intensive care unit (NICU) is an environment that provides premature and fragile infants with health provisions needed to make a complete recovery. Premature infants are often born before their auditory systems have had an opportunity to fully mature. Research has shown that the ambient acoustic environment in the NICU exceeds the maximum noise level recommended by the American Academy of Pediatrics, even after measures have been taken to decrease noise levels. The purpose of this study is to evaluate noise levels inside an Ohmeda Medical Giraffe TM OmniBed TM , the natural attenuation of the incubator, and the effects of modifications on attenuation and reverberation within the Giraffe TM OmniBed TM . The normal operation of the Giraffe TM OmniBed TM is 41.7 dBA which indicates a lower noise of operation than previous studies. The Giraffe TM OmniBed TM naturally attenuates 12 dBA. Leaving an access latch or portal door open causes a statistically significant (P=.001) increase in sound within the bassinet. All modifications in the no-noise and the noise conditions showed a statistically significant (P=.001) drop in Leq when compared to baseline.http://www.noiseandhealth.org/article.asp?issn=1463-1741;year=2011;volume=13;issue=50;spage=37;epage=44;aulast=WubbenNeonatal intensive care unit designprematuritysound attenuationdBA
collection DOAJ
language English
format Article
sources DOAJ
author Stephanie M Wubben
Paul M Brueggeman
Dennis C Stevens
Carol C Helseth
Kristen Blaschke
spellingShingle Stephanie M Wubben
Paul M Brueggeman
Dennis C Stevens
Carol C Helseth
Kristen Blaschke
The sound of operation and the acoustic attenuation of the Ohmeda Medical Giraffe OmniBed TM
Noise and Health
Neonatal intensive care unit design
prematurity
sound attenuation
dBA
author_facet Stephanie M Wubben
Paul M Brueggeman
Dennis C Stevens
Carol C Helseth
Kristen Blaschke
author_sort Stephanie M Wubben
title The sound of operation and the acoustic attenuation of the Ohmeda Medical Giraffe OmniBed TM
title_short The sound of operation and the acoustic attenuation of the Ohmeda Medical Giraffe OmniBed TM
title_full The sound of operation and the acoustic attenuation of the Ohmeda Medical Giraffe OmniBed TM
title_fullStr The sound of operation and the acoustic attenuation of the Ohmeda Medical Giraffe OmniBed TM
title_full_unstemmed The sound of operation and the acoustic attenuation of the Ohmeda Medical Giraffe OmniBed TM
title_sort sound of operation and the acoustic attenuation of the ohmeda medical giraffe omnibed tm
publisher Wolters Kluwer Medknow Publications
series Noise and Health
issn 1463-1741
1998-4030
publishDate 2011-01-01
description The neonatal intensive care unit (NICU) is an environment that provides premature and fragile infants with health provisions needed to make a complete recovery. Premature infants are often born before their auditory systems have had an opportunity to fully mature. Research has shown that the ambient acoustic environment in the NICU exceeds the maximum noise level recommended by the American Academy of Pediatrics, even after measures have been taken to decrease noise levels. The purpose of this study is to evaluate noise levels inside an Ohmeda Medical Giraffe TM OmniBed TM , the natural attenuation of the incubator, and the effects of modifications on attenuation and reverberation within the Giraffe TM OmniBed TM . The normal operation of the Giraffe TM OmniBed TM is 41.7 dBA which indicates a lower noise of operation than previous studies. The Giraffe TM OmniBed TM naturally attenuates 12 dBA. Leaving an access latch or portal door open causes a statistically significant (P=.001) increase in sound within the bassinet. All modifications in the no-noise and the noise conditions showed a statistically significant (P=.001) drop in Leq when compared to baseline.
topic Neonatal intensive care unit design
prematurity
sound attenuation
dBA
url http://www.noiseandhealth.org/article.asp?issn=1463-1741;year=2011;volume=13;issue=50;spage=37;epage=44;aulast=Wubben
work_keys_str_mv AT stephaniemwubben thesoundofoperationandtheacousticattenuationoftheohmedamedicalgiraffeomnibedtm
AT paulmbrueggeman thesoundofoperationandtheacousticattenuationoftheohmedamedicalgiraffeomnibedtm
AT denniscstevens thesoundofoperationandtheacousticattenuationoftheohmedamedicalgiraffeomnibedtm
AT carolchelseth thesoundofoperationandtheacousticattenuationoftheohmedamedicalgiraffeomnibedtm
AT kristenblaschke thesoundofoperationandtheacousticattenuationoftheohmedamedicalgiraffeomnibedtm
AT stephaniemwubben soundofoperationandtheacousticattenuationoftheohmedamedicalgiraffeomnibedtm
AT paulmbrueggeman soundofoperationandtheacousticattenuationoftheohmedamedicalgiraffeomnibedtm
AT denniscstevens soundofoperationandtheacousticattenuationoftheohmedamedicalgiraffeomnibedtm
AT carolchelseth soundofoperationandtheacousticattenuationoftheohmedamedicalgiraffeomnibedtm
AT kristenblaschke soundofoperationandtheacousticattenuationoftheohmedamedicalgiraffeomnibedtm
_version_ 1725387785577168896