Adaptação dos testes de lactato mínimo, potência crítica e limiar anaeróbio para avaliação da transição anaeróbia-anaeróbia em protocolo específico para o tênis de mesa Adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennis

Os objetivos do estudo foram verificar a adaptação dos testes de lactato mínimo, freqüência crítica e limiar anaeróbio em protocolo específico para o tênis de mesa para avaliação da transição anaeróbia-anaeróbia; verificar a reprodutibilidade do teste de lactato mínimo; e verificar a associação dess...

Full description

Bibliographic Details
Main Authors: Érika Alves Morel, Alessandro Moura Zagatto
Format: Article
Language:English
Published: Sociedade Brasileira de Medicina do Esporte 2008-12-01
Series:Revista Brasileira de Medicina do Esporte
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922008000600009
id doaj-fb74445b615b4c70add7ca93c3bc1ad1
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Érika Alves Morel
Alessandro Moura Zagatto
spellingShingle Érika Alves Morel
Alessandro Moura Zagatto
Adaptação dos testes de lactato mínimo, potência crítica e limiar anaeróbio para avaliação da transição anaeróbia-anaeróbia em protocolo específico para o tênis de mesa Adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennis
Revista Brasileira de Medicina do Esporte
lactato
lançador de bolas mecânico
reprodutibilidade
especificidade
tênis de mesa
lactate
mechanical balls thrower
reproducibility
specificity
table tennis
author_facet Érika Alves Morel
Alessandro Moura Zagatto
author_sort Érika Alves Morel
title Adaptação dos testes de lactato mínimo, potência crítica e limiar anaeróbio para avaliação da transição anaeróbia-anaeróbia em protocolo específico para o tênis de mesa Adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennis
title_short Adaptação dos testes de lactato mínimo, potência crítica e limiar anaeróbio para avaliação da transição anaeróbia-anaeróbia em protocolo específico para o tênis de mesa Adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennis
title_full Adaptação dos testes de lactato mínimo, potência crítica e limiar anaeróbio para avaliação da transição anaeróbia-anaeróbia em protocolo específico para o tênis de mesa Adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennis
title_fullStr Adaptação dos testes de lactato mínimo, potência crítica e limiar anaeróbio para avaliação da transição anaeróbia-anaeróbia em protocolo específico para o tênis de mesa Adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennis
title_full_unstemmed Adaptação dos testes de lactato mínimo, potência crítica e limiar anaeróbio para avaliação da transição anaeróbia-anaeróbia em protocolo específico para o tênis de mesa Adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennis
title_sort adaptação dos testes de lactato mínimo, potência crítica e limiar anaeróbio para avaliação da transição anaeróbia-anaeróbia em protocolo específico para o tênis de mesa adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennis
publisher Sociedade Brasileira de Medicina do Esporte
series Revista Brasileira de Medicina do Esporte
issn 1517-8692
1806-9940
publishDate 2008-12-01
description Os objetivos do estudo foram verificar a adaptação dos testes de lactato mínimo, freqüência crítica e limiar anaeróbio em protocolo específico para o tênis de mesa para avaliação da transição anaeróbia-anaeróbia; verificar a reprodutibilidade do teste de lactato mínimo; e verificar a associação desses procedimentos específicos com o limiar anaeróbio determinado em corrida em esteira rolante (LAn est). Para isso, foram estudados 11 mesatenistas com tempo mínimo de treinamento de dois anos. Foram aplicados os testes de: 1) lactato mínimo em duas ocasiões para análise da reprodutibilidade (LACmin1 e LACmin2); 2) teste de freqüência crítica (fcrit); 3) teste incremental para determinação do limiar anaeróbio através da concentração fixa de lactato de 3,5mM (LAn esp3,5) e regressão linear bissegmentada (LAnBI), todos em procedimentos específicos para o tênis de mesa; e 4) o limiar anaeróbio em corrida aplicado em esteira rolante (LAn est) determinado pela concentração fixa de lactato de 3,5mM. Nos procedimentos específicos foi utilizado um lançador de bolas mecânico como ergômetro e os participantes realizaram golpes apenas de forehand. Como procedimentos estatísticos foram utilizados os testes de Bland-Altman, correlação produto-momento e ANOVA one way, com nível de significância de 5%. As intensidades de LACmin (59,40 ± 4,06 e 61,56 ± 8,97 bolas.min-1) apresentaram boa concordância (teste de Bland-Altman) e foram significativamente correlacionadas (0,61). A fcrit, o LAn esp3,5 e o LAnBI foram correspondentes a 56,50 ± 6,84 bolas.min-1; 66,74 ± 5,03 bolas.min-1; e 62,67 ± 7,25 bolas.min-1, respectivamente. Foi verificada apenas diferença significativa entre as intensidades de LAn esp3,5 e de fcrit. Foram encontradas correlações significativas entre LACmin1 e LACmin2 (0,61), LACmin1 e fcrit (0,61), LACmin2 e fcrit (0,69), LAn esp3,5 e LAnBI (0,70), enquanto que o LAn est (9,11 ± 1,94km.h-1) foi apenas correlacionado com a intensidade de fcrit (0,73). Desse modo, pode-se concluir que o teste de LACmin específico é reprodutível e que esse procedimento, assim como o teste de fcrit, pode ser aplicado para avaliar a transição aeróbia-anaeróbia no tênis de mesa e que o LAn est deve ser utilizado com cautela na avaliação de mesatenistas.<br>The aims of the present study were to adapt the lactate minimum, critical power model and anaerobic threshold tests for assessment of the aerobic-anaerobic transition in specific test for table tennis; to verify the reproducibility of the lactate minimum test and to verify the relationship between these specific procedures with the anaerobic threshold determined in running on treadmill (AnT TR). Eleven male table tennis players participated in the study. The participants performed four tests (three specific tests and a conventional test performed on a treadmill): 1) lactate minimum test (LACmin) (applied twice for reproducibility analyses - LACmim1 and LACmin2); 2) critical frequency test (critf); 3) incremental test for anaerobic threshold determination by 3.5 mM steady lactate concentration (AnT3.5) and bi-segmented linear regression (AnT BI) methods, all in specific protocol; and 4) anaerobic threshold on running (AnT TR). Specific tests were applied by using a mechanical ball thrower to control the intensity of the exercise. The Bland-Altman plot, product-moment correlation and One-way ANOVA tests were used as statistical procedure, with significance level at 5%. The LACmin intensities (59.40 ± 4.06 balls.min-1 and 61.56 ± 8.97 balls.min-1) presented significant correlation (r = 0.61) and moderate concordance verified by Bland-Altman plot. The critf, AnT3.5 and AnT BI intensities corresponded to 56.50 ± 6.84 balls.min-1, 66.74 ± 5.03 balls.min-1 and 62.67 ± 7.25 balls.min-1, respectively, and only AnT3.5 and critf were different. Significant correlations were obtained amongst LACmin1 and critf (r = 0.61), LACmin2 and critf (r = 0.69), and AnT3.5 and AnT BI (r = 0.70). Anaerobic threshold determined in running (9.11 ± 1.94 Km.h-1) was only correlated with the critf (r = 0.73). Thus, in conclusion, the lactate minimum test specific for table tennis is a reproducible procedure, as well as the critf test can be applied for evaluating aerobic-anaerobic transition. Neverhteless, the anaerobic threshold applied in running on a treadmill must be used with care in table tennis.
topic lactato
lançador de bolas mecânico
reprodutibilidade
especificidade
tênis de mesa
lactate
mechanical balls thrower
reproducibility
specificity
table tennis
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922008000600009
work_keys_str_mv AT erikaalvesmorel adaptacaodostestesdelactatominimopotenciacriticaelimiaranaerobioparaavaliacaodatransicaoanaerobiaanaerobiaemprotocoloespecificoparaotenisdemesaadaptationofthelactateminimumcriticalpowerandanaerobicthresholdtestsforassessmentoftheaerobicanaerobictransition
AT alessandromourazagatto adaptacaodostestesdelactatominimopotenciacriticaelimiaranaerobioparaavaliacaodatransicaoanaerobiaanaerobiaemprotocoloespecificoparaotenisdemesaadaptationofthelactateminimumcriticalpowerandanaerobicthresholdtestsforassessmentoftheaerobicanaerobictransition
_version_ 1725531463452983296
spelling doaj-fb74445b615b4c70add7ca93c3bc1ad12020-11-24T23:33:16ZengSociedade Brasileira de Medicina do EsporteRevista Brasileira de Medicina do Esporte1517-86921806-99402008-12-0114651852210.1590/S1517-86922008000600009Adaptação dos testes de lactato mínimo, potência crítica e limiar anaeróbio para avaliação da transição anaeróbia-anaeróbia em protocolo específico para o tênis de mesa Adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennisÉrika Alves MorelAlessandro Moura ZagattoOs objetivos do estudo foram verificar a adaptação dos testes de lactato mínimo, freqüência crítica e limiar anaeróbio em protocolo específico para o tênis de mesa para avaliação da transição anaeróbia-anaeróbia; verificar a reprodutibilidade do teste de lactato mínimo; e verificar a associação desses procedimentos específicos com o limiar anaeróbio determinado em corrida em esteira rolante (LAn est). Para isso, foram estudados 11 mesatenistas com tempo mínimo de treinamento de dois anos. Foram aplicados os testes de: 1) lactato mínimo em duas ocasiões para análise da reprodutibilidade (LACmin1 e LACmin2); 2) teste de freqüência crítica (fcrit); 3) teste incremental para determinação do limiar anaeróbio através da concentração fixa de lactato de 3,5mM (LAn esp3,5) e regressão linear bissegmentada (LAnBI), todos em procedimentos específicos para o tênis de mesa; e 4) o limiar anaeróbio em corrida aplicado em esteira rolante (LAn est) determinado pela concentração fixa de lactato de 3,5mM. Nos procedimentos específicos foi utilizado um lançador de bolas mecânico como ergômetro e os participantes realizaram golpes apenas de forehand. Como procedimentos estatísticos foram utilizados os testes de Bland-Altman, correlação produto-momento e ANOVA one way, com nível de significância de 5%. As intensidades de LACmin (59,40 ± 4,06 e 61,56 ± 8,97 bolas.min-1) apresentaram boa concordância (teste de Bland-Altman) e foram significativamente correlacionadas (0,61). A fcrit, o LAn esp3,5 e o LAnBI foram correspondentes a 56,50 ± 6,84 bolas.min-1; 66,74 ± 5,03 bolas.min-1; e 62,67 ± 7,25 bolas.min-1, respectivamente. Foi verificada apenas diferença significativa entre as intensidades de LAn esp3,5 e de fcrit. Foram encontradas correlações significativas entre LACmin1 e LACmin2 (0,61), LACmin1 e fcrit (0,61), LACmin2 e fcrit (0,69), LAn esp3,5 e LAnBI (0,70), enquanto que o LAn est (9,11 ± 1,94km.h-1) foi apenas correlacionado com a intensidade de fcrit (0,73). Desse modo, pode-se concluir que o teste de LACmin específico é reprodutível e que esse procedimento, assim como o teste de fcrit, pode ser aplicado para avaliar a transição aeróbia-anaeróbia no tênis de mesa e que o LAn est deve ser utilizado com cautela na avaliação de mesatenistas.<br>The aims of the present study were to adapt the lactate minimum, critical power model and anaerobic threshold tests for assessment of the aerobic-anaerobic transition in specific test for table tennis; to verify the reproducibility of the lactate minimum test and to verify the relationship between these specific procedures with the anaerobic threshold determined in running on treadmill (AnT TR). Eleven male table tennis players participated in the study. The participants performed four tests (three specific tests and a conventional test performed on a treadmill): 1) lactate minimum test (LACmin) (applied twice for reproducibility analyses - LACmim1 and LACmin2); 2) critical frequency test (critf); 3) incremental test for anaerobic threshold determination by 3.5 mM steady lactate concentration (AnT3.5) and bi-segmented linear regression (AnT BI) methods, all in specific protocol; and 4) anaerobic threshold on running (AnT TR). Specific tests were applied by using a mechanical ball thrower to control the intensity of the exercise. The Bland-Altman plot, product-moment correlation and One-way ANOVA tests were used as statistical procedure, with significance level at 5%. The LACmin intensities (59.40 ± 4.06 balls.min-1 and 61.56 ± 8.97 balls.min-1) presented significant correlation (r = 0.61) and moderate concordance verified by Bland-Altman plot. The critf, AnT3.5 and AnT BI intensities corresponded to 56.50 ± 6.84 balls.min-1, 66.74 ± 5.03 balls.min-1 and 62.67 ± 7.25 balls.min-1, respectively, and only AnT3.5 and critf were different. Significant correlations were obtained amongst LACmin1 and critf (r = 0.61), LACmin2 and critf (r = 0.69), and AnT3.5 and AnT BI (r = 0.70). Anaerobic threshold determined in running (9.11 ± 1.94 Km.h-1) was only correlated with the critf (r = 0.73). Thus, in conclusion, the lactate minimum test specific for table tennis is a reproducible procedure, as well as the critf test can be applied for evaluating aerobic-anaerobic transition. Neverhteless, the anaerobic threshold applied in running on a treadmill must be used with care in table tennis.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922008000600009lactatolançador de bolas mecânicoreprodutibilidadeespecificidadetênis de mesalactatemechanical balls throwerreproducibilityspecificitytable tennis