Preliminary study to the temperatures of the thermocouple probes affected by the environment of heated walls
Measuring of the total temperatures of the flowing medium is one of the pivotal points in the development when a new compressor stages are tested. Measurements conducted on the test compressor indicated that in the specific cases the measured temperature can be affected by the temperature of the wal...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2016-01-01
|
Series: | EPJ Web of Conferences |
Online Access: | http://dx.doi.org/10.1051/epjconf/201611402071 |
id |
doaj-fb6e04690530459ba5ac2cbe1033a978 |
---|---|
record_format |
Article |
spelling |
doaj-fb6e04690530459ba5ac2cbe1033a9782021-08-02T05:39:00ZengEDP SciencesEPJ Web of Conferences2100-014X2016-01-011140207110.1051/epjconf/201611402071epjconf_efm2016_02071Preliminary study to the temperatures of the thermocouple probes affected by the environment of heated wallsMatas Richard0Sedláček Jan1Čibera Václav2New Technologies – Research Centre, University of West Bohemia, Univerzitni 8New Technologies – Research Centre, University of West Bohemia, Univerzitni 8New Technologies – Research Centre, University of West Bohemia, Univerzitni 8Measuring of the total temperatures of the flowing medium is one of the pivotal points in the development when a new compressor stages are tested. Measurements conducted on the test compressor indicated that in the specific cases the measured temperature can be affected by the temperature of the walls which hold thermocouple probe. By implication of this observed fact, the preliminary study about this phenomenon was investigated. It was considered the influence of the heat conduction in the body of the probe and in the thermocouples. The main aim of the study was to examine the properties and the behaviour of the thermocouple probes in various working regimes. The preliminary study was focused on the development of the tools that can be used for complex solution of the problem by using of measured data. The results of this study might help to correct measured data in the case of skewed measurements affected by surroundings of the thermocouple probes.http://dx.doi.org/10.1051/epjconf/201611402071 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Matas Richard Sedláček Jan Čibera Václav |
spellingShingle |
Matas Richard Sedláček Jan Čibera Václav Preliminary study to the temperatures of the thermocouple probes affected by the environment of heated walls EPJ Web of Conferences |
author_facet |
Matas Richard Sedláček Jan Čibera Václav |
author_sort |
Matas Richard |
title |
Preliminary study to the temperatures of the thermocouple probes affected by the environment of heated walls |
title_short |
Preliminary study to the temperatures of the thermocouple probes affected by the environment of heated walls |
title_full |
Preliminary study to the temperatures of the thermocouple probes affected by the environment of heated walls |
title_fullStr |
Preliminary study to the temperatures of the thermocouple probes affected by the environment of heated walls |
title_full_unstemmed |
Preliminary study to the temperatures of the thermocouple probes affected by the environment of heated walls |
title_sort |
preliminary study to the temperatures of the thermocouple probes affected by the environment of heated walls |
publisher |
EDP Sciences |
series |
EPJ Web of Conferences |
issn |
2100-014X |
publishDate |
2016-01-01 |
description |
Measuring of the total temperatures of the flowing medium is one of the pivotal points in the development when a new compressor stages are tested. Measurements conducted on the test compressor indicated that in the specific cases the measured temperature can be affected by the temperature of the walls which hold thermocouple probe. By implication of this observed fact, the preliminary study about this phenomenon was investigated. It was considered the influence of the heat conduction in the body of the probe and in the thermocouples. The main aim of the study was to examine the properties and the behaviour of the thermocouple probes in various working regimes. The preliminary study was focused on the development of the tools that can be used for complex solution of the problem by using of measured data. The results of this study might help to correct measured data in the case of skewed measurements affected by surroundings of the thermocouple probes. |
url |
http://dx.doi.org/10.1051/epjconf/201611402071 |
work_keys_str_mv |
AT matasrichard preliminarystudytothetemperaturesofthethermocoupleprobesaffectedbytheenvironmentofheatedwalls AT sedlacekjan preliminarystudytothetemperaturesofthethermocoupleprobesaffectedbytheenvironmentofheatedwalls AT ciberavaclav preliminarystudytothetemperaturesofthethermocoupleprobesaffectedbytheenvironmentofheatedwalls |