Assessment of the diagnostic performance of TrueHb® point-of-care hemometer compared with Sysmex i3 analyzer among patients at International Hospital Kampala, Uganda

Ivan Mugisha Taremwa,1 Ivan Ndeze,1 Bashir Mwambi,1 Christine Atuhairwe,2 Diana Inda Achieng,3 Bernard Natukunda41Department of Medical Laboratory Sciences, Institute of Allied Health Sciences, Clarke International University, Kampala, Uganda; 2Institute of Public Health and Management, Clarke Inter...

Full description

Bibliographic Details
Main Authors: Taremwa IM, Ndeze I, Mwambi B, Atuhairwe C, Achieng DI, Natukunda B
Format: Article
Language:English
Published: Dove Medical Press 2019-04-01
Series:Journal of Blood Medicine
Subjects:
Online Access:https://www.dovepress.com/assessment-of-the-diagnostic-performance-of-truehbreg-point-of-care-he-peer-reviewed-article-JBM
id doaj-fb698dd847f44e9ba31f14bf14eb45d3
record_format Article
spelling doaj-fb698dd847f44e9ba31f14bf14eb45d32020-11-24T23:34:59ZengDove Medical PressJournal of Blood Medicine1179-27362019-04-01Volume 10859244865Assessment of the diagnostic performance of TrueHb® point-of-care hemometer compared with Sysmex i3 analyzer among patients at International Hospital Kampala, UgandaTaremwa IMNdeze IMwambi BAtuhairwe CAchieng DINatukunda BIvan Mugisha Taremwa,1 Ivan Ndeze,1 Bashir Mwambi,1 Christine Atuhairwe,2 Diana Inda Achieng,3 Bernard Natukunda41Department of Medical Laboratory Sciences, Institute of Allied Health Sciences, Clarke International University, Kampala, Uganda; 2Institute of Public Health and Management, Clarke International University, Kampala, Uganda; 3Lancet Laboratories, Kampala, Uganda; 4Department of  Medical Laboratory Sciences, Faculty of Medicine, Mbarara University of Science and Technology, Mbarara, UgandaAim/Objective: To assess the diagnostic performance of TrueHb® point-of-care (POC) hemometer compared with Sysmex i3 analyzer at International Hospital Kampala, Uganda.Materials and methods: We analyzed ethylenediaminetetraacetic acid blood samples to estimate hemoglobin (Hb) levels using parallel testing with TrueHb® hemometer and Sysmex i3 analyzer. Data were analyzed to ascertain the diagnostic performance of the test assays using the Bland and Altman method. Sensitivity, specificity, positive and negative predictive values were calculated.Results: The study enrolled 402 patients; of these, 156 (38.8%) were males. The average Hb levels were 8.7±1.8 and 13.3±2.6 g/dL for the anemic and nonanemic patients, respectively. One hundred and fifty-five participants were anemic, giving anemia prevalence of 38.56% (95% CI: 35.17–40.38). The mean difference of the TrueHb® and Sysmex i3 assays was 2.2219 (SD 1.07915), and the two devices did not show a difference in their measurements (t=−2.407, p-value 0.017, 95% CI: −0.095–0.010). Further, they showed a significant level of agreement (t=41.281; 95% CI: 2.1161–2.3277) and intraclass correlation coefficients (ICC=0.793). The sensitivity, specificity, positive and negative predictive values were 100.00%, 51.01%, 55.16% and 100.00%, respectively. The average performance turnaround time (TAT) for the TrueHb® hemometer was 2.46 mins (95% CI: 2.37–2.55).Conclusion: TrueHb® POC hemometer is an accurate POC for Hb estimation with a good performance agreement with the Sysmex i3 analyzer. This, coupled with its utility aspects, makes it a good diagnostic tool in a high anemia burden and low-resource setting.Keywords: anemia, hemoglobin estimation, point-of-care testing, TrueHb®, Sysmex i3, Ugandahttps://www.dovepress.com/assessment-of-the-diagnostic-performance-of-truehbreg-point-of-care-he-peer-reviewed-article-JBMAnemiaHemoglobin estimationpoint-of-care testingTrueHb®Sysmex i3Uganda
collection DOAJ
language English
format Article
sources DOAJ
author Taremwa IM
Ndeze I
Mwambi B
Atuhairwe C
Achieng DI
Natukunda B
spellingShingle Taremwa IM
Ndeze I
Mwambi B
Atuhairwe C
Achieng DI
Natukunda B
Assessment of the diagnostic performance of TrueHb® point-of-care hemometer compared with Sysmex i3 analyzer among patients at International Hospital Kampala, Uganda
Journal of Blood Medicine
Anemia
Hemoglobin estimation
point-of-care testing
TrueHb®
Sysmex i3
Uganda
author_facet Taremwa IM
Ndeze I
Mwambi B
Atuhairwe C
Achieng DI
Natukunda B
author_sort Taremwa IM
title Assessment of the diagnostic performance of TrueHb® point-of-care hemometer compared with Sysmex i3 analyzer among patients at International Hospital Kampala, Uganda
title_short Assessment of the diagnostic performance of TrueHb® point-of-care hemometer compared with Sysmex i3 analyzer among patients at International Hospital Kampala, Uganda
title_full Assessment of the diagnostic performance of TrueHb® point-of-care hemometer compared with Sysmex i3 analyzer among patients at International Hospital Kampala, Uganda
title_fullStr Assessment of the diagnostic performance of TrueHb® point-of-care hemometer compared with Sysmex i3 analyzer among patients at International Hospital Kampala, Uganda
title_full_unstemmed Assessment of the diagnostic performance of TrueHb® point-of-care hemometer compared with Sysmex i3 analyzer among patients at International Hospital Kampala, Uganda
title_sort assessment of the diagnostic performance of truehb® point-of-care hemometer compared with sysmex i3 analyzer among patients at international hospital kampala, uganda
publisher Dove Medical Press
series Journal of Blood Medicine
issn 1179-2736
publishDate 2019-04-01
description Ivan Mugisha Taremwa,1 Ivan Ndeze,1 Bashir Mwambi,1 Christine Atuhairwe,2 Diana Inda Achieng,3 Bernard Natukunda41Department of Medical Laboratory Sciences, Institute of Allied Health Sciences, Clarke International University, Kampala, Uganda; 2Institute of Public Health and Management, Clarke International University, Kampala, Uganda; 3Lancet Laboratories, Kampala, Uganda; 4Department of  Medical Laboratory Sciences, Faculty of Medicine, Mbarara University of Science and Technology, Mbarara, UgandaAim/Objective: To assess the diagnostic performance of TrueHb® point-of-care (POC) hemometer compared with Sysmex i3 analyzer at International Hospital Kampala, Uganda.Materials and methods: We analyzed ethylenediaminetetraacetic acid blood samples to estimate hemoglobin (Hb) levels using parallel testing with TrueHb® hemometer and Sysmex i3 analyzer. Data were analyzed to ascertain the diagnostic performance of the test assays using the Bland and Altman method. Sensitivity, specificity, positive and negative predictive values were calculated.Results: The study enrolled 402 patients; of these, 156 (38.8%) were males. The average Hb levels were 8.7±1.8 and 13.3±2.6 g/dL for the anemic and nonanemic patients, respectively. One hundred and fifty-five participants were anemic, giving anemia prevalence of 38.56% (95% CI: 35.17–40.38). The mean difference of the TrueHb® and Sysmex i3 assays was 2.2219 (SD 1.07915), and the two devices did not show a difference in their measurements (t=−2.407, p-value 0.017, 95% CI: −0.095–0.010). Further, they showed a significant level of agreement (t=41.281; 95% CI: 2.1161–2.3277) and intraclass correlation coefficients (ICC=0.793). The sensitivity, specificity, positive and negative predictive values were 100.00%, 51.01%, 55.16% and 100.00%, respectively. The average performance turnaround time (TAT) for the TrueHb® hemometer was 2.46 mins (95% CI: 2.37–2.55).Conclusion: TrueHb® POC hemometer is an accurate POC for Hb estimation with a good performance agreement with the Sysmex i3 analyzer. This, coupled with its utility aspects, makes it a good diagnostic tool in a high anemia burden and low-resource setting.Keywords: anemia, hemoglobin estimation, point-of-care testing, TrueHb®, Sysmex i3, Uganda
topic Anemia
Hemoglobin estimation
point-of-care testing
TrueHb®
Sysmex i3
Uganda
url https://www.dovepress.com/assessment-of-the-diagnostic-performance-of-truehbreg-point-of-care-he-peer-reviewed-article-JBM
work_keys_str_mv AT taremwaim assessmentofthediagnosticperformanceoftruehbregpointofcarehemometercomparedwithsysmexi3analyzeramongpatientsatinternationalhospitalkampalauganda
AT ndezei assessmentofthediagnosticperformanceoftruehbregpointofcarehemometercomparedwithsysmexi3analyzeramongpatientsatinternationalhospitalkampalauganda
AT mwambib assessmentofthediagnosticperformanceoftruehbregpointofcarehemometercomparedwithsysmexi3analyzeramongpatientsatinternationalhospitalkampalauganda
AT atuhairwec assessmentofthediagnosticperformanceoftruehbregpointofcarehemometercomparedwithsysmexi3analyzeramongpatientsatinternationalhospitalkampalauganda
AT achiengdi assessmentofthediagnosticperformanceoftruehbregpointofcarehemometercomparedwithsysmexi3analyzeramongpatientsatinternationalhospitalkampalauganda
AT natukundab assessmentofthediagnosticperformanceoftruehbregpointofcarehemometercomparedwithsysmexi3analyzeramongpatientsatinternationalhospitalkampalauganda
_version_ 1725526630853509120