Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry

The anti-streptolysin O (ASO) test, which depends upon age and geographic location, is used to provide evidence for antecedent streptococcal infection in patients suspected of having rheumatic fever. Reference values of ASO have not previously been determined by nephelometric assay for laboratory u...

Full description

Bibliographic Details
Main Authors: Ronnachai Viriyataveekul, Supaporn Chaihirunkarn, Sumalee Potprasat, Sudarat Sarovath, Sasitorn Bejrachandra
Format: Article
Language:English
Published: Mahidol University 2020-08-01
Series:Siriraj Medical Journal
Subjects:
Online Access:https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/244996
id doaj-fb4d3904a68e45bf8349eeed0a40865b
record_format Article
spelling doaj-fb4d3904a68e45bf8349eeed0a40865b2021-08-13T09:42:40ZengMahidol UniversitySiriraj Medical Journal2228-80822020-08-01538Reference Values of Serum Anti-streptolysin O in Adults by NephelometryRonnachai Viriyataveekul0Supaporn Chaihirunkarn1Sumalee Potprasat2Sudarat Sarovath3Sasitorn Bejrachandra4Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700Department of Transfution Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 The anti-streptolysin O (ASO) test, which depends upon age and geographic location, is used to provide evidence for antecedent streptococcal infection in patients suspected of having rheumatic fever. Reference values of ASO have not previously been determined by nephelometric assay for laboratory use at Siriraj Hospital. A total of 402 serum specimens were collected from healthy adults aged between 16 and 63 years in Siriraj Hospital. They consisted of 235 blood donors, 150 subjects who were going to study aboard and 17 dentists. ASO concentrations from 5 groups according to five age ranges were compared and it was found that two age ranges which were 25 years old and younger and 26 years and older were appropriate to determine reference values. The reference values of ASO for these two age ranges, with 90% confidence intervals, were 486 (401-673) IU/ml and 385 (362-500) IU/ml, respectively. https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/244996Reference ValuesSerumAnti-streptolysin ONephelometry
collection DOAJ
language English
format Article
sources DOAJ
author Ronnachai Viriyataveekul
Supaporn Chaihirunkarn
Sumalee Potprasat
Sudarat Sarovath
Sasitorn Bejrachandra
spellingShingle Ronnachai Viriyataveekul
Supaporn Chaihirunkarn
Sumalee Potprasat
Sudarat Sarovath
Sasitorn Bejrachandra
Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry
Siriraj Medical Journal
Reference Values
Serum
Anti-streptolysin O
Nephelometry
author_facet Ronnachai Viriyataveekul
Supaporn Chaihirunkarn
Sumalee Potprasat
Sudarat Sarovath
Sasitorn Bejrachandra
author_sort Ronnachai Viriyataveekul
title Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry
title_short Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry
title_full Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry
title_fullStr Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry
title_full_unstemmed Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry
title_sort reference values of serum anti-streptolysin o in adults by nephelometry
publisher Mahidol University
series Siriraj Medical Journal
issn 2228-8082
publishDate 2020-08-01
description The anti-streptolysin O (ASO) test, which depends upon age and geographic location, is used to provide evidence for antecedent streptococcal infection in patients suspected of having rheumatic fever. Reference values of ASO have not previously been determined by nephelometric assay for laboratory use at Siriraj Hospital. A total of 402 serum specimens were collected from healthy adults aged between 16 and 63 years in Siriraj Hospital. They consisted of 235 blood donors, 150 subjects who were going to study aboard and 17 dentists. ASO concentrations from 5 groups according to five age ranges were compared and it was found that two age ranges which were 25 years old and younger and 26 years and older were appropriate to determine reference values. The reference values of ASO for these two age ranges, with 90% confidence intervals, were 486 (401-673) IU/ml and 385 (362-500) IU/ml, respectively.
topic Reference Values
Serum
Anti-streptolysin O
Nephelometry
url https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/244996
work_keys_str_mv AT ronnachaiviriyataveekul referencevaluesofserumantistreptolysinoinadultsbynephelometry
AT supapornchaihirunkarn referencevaluesofserumantistreptolysinoinadultsbynephelometry
AT sumaleepotprasat referencevaluesofserumantistreptolysinoinadultsbynephelometry
AT sudaratsarovath referencevaluesofserumantistreptolysinoinadultsbynephelometry
AT sasitornbejrachandra referencevaluesofserumantistreptolysinoinadultsbynephelometry
_version_ 1721209037292306432