Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry
The anti-streptolysin O (ASO) test, which depends upon age and geographic location, is used to provide evidence for antecedent streptococcal infection in patients suspected of having rheumatic fever. Reference values of ASO have not previously been determined by nephelometric assay for laboratory u...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Mahidol University
2020-08-01
|
Series: | Siriraj Medical Journal |
Subjects: | |
Online Access: | https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/244996 |
id |
doaj-fb4d3904a68e45bf8349eeed0a40865b |
---|---|
record_format |
Article |
spelling |
doaj-fb4d3904a68e45bf8349eeed0a40865b2021-08-13T09:42:40ZengMahidol UniversitySiriraj Medical Journal2228-80822020-08-01538Reference Values of Serum Anti-streptolysin O in Adults by NephelometryRonnachai Viriyataveekul0Supaporn Chaihirunkarn1Sumalee Potprasat2Sudarat Sarovath3Sasitorn Bejrachandra4Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700Department of Transfution Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 The anti-streptolysin O (ASO) test, which depends upon age and geographic location, is used to provide evidence for antecedent streptococcal infection in patients suspected of having rheumatic fever. Reference values of ASO have not previously been determined by nephelometric assay for laboratory use at Siriraj Hospital. A total of 402 serum specimens were collected from healthy adults aged between 16 and 63 years in Siriraj Hospital. They consisted of 235 blood donors, 150 subjects who were going to study aboard and 17 dentists. ASO concentrations from 5 groups according to five age ranges were compared and it was found that two age ranges which were 25 years old and younger and 26 years and older were appropriate to determine reference values. The reference values of ASO for these two age ranges, with 90% confidence intervals, were 486 (401-673) IU/ml and 385 (362-500) IU/ml, respectively. https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/244996Reference ValuesSerumAnti-streptolysin ONephelometry |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ronnachai Viriyataveekul Supaporn Chaihirunkarn Sumalee Potprasat Sudarat Sarovath Sasitorn Bejrachandra |
spellingShingle |
Ronnachai Viriyataveekul Supaporn Chaihirunkarn Sumalee Potprasat Sudarat Sarovath Sasitorn Bejrachandra Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry Siriraj Medical Journal Reference Values Serum Anti-streptolysin O Nephelometry |
author_facet |
Ronnachai Viriyataveekul Supaporn Chaihirunkarn Sumalee Potprasat Sudarat Sarovath Sasitorn Bejrachandra |
author_sort |
Ronnachai Viriyataveekul |
title |
Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry |
title_short |
Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry |
title_full |
Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry |
title_fullStr |
Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry |
title_full_unstemmed |
Reference Values of Serum Anti-streptolysin O in Adults by Nephelometry |
title_sort |
reference values of serum anti-streptolysin o in adults by nephelometry |
publisher |
Mahidol University |
series |
Siriraj Medical Journal |
issn |
2228-8082 |
publishDate |
2020-08-01 |
description |
The anti-streptolysin O (ASO) test, which depends upon age and geographic location, is used to provide evidence for antecedent streptococcal infection in patients suspected of having rheumatic fever. Reference values of ASO have not previously been determined by nephelometric assay for laboratory use at Siriraj Hospital. A total of 402 serum specimens were collected from healthy adults aged between 16 and 63 years in Siriraj Hospital. They consisted of 235 blood donors, 150 subjects who were going to study aboard and 17 dentists. ASO concentrations from 5 groups according to five age ranges were compared and it was found that two age ranges which were 25 years old and younger and 26 years and older were appropriate to determine reference values. The reference values of ASO for these two age ranges, with 90% confidence intervals, were 486 (401-673) IU/ml and 385 (362-500) IU/ml, respectively.
|
topic |
Reference Values Serum Anti-streptolysin O Nephelometry |
url |
https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/244996 |
work_keys_str_mv |
AT ronnachaiviriyataveekul referencevaluesofserumantistreptolysinoinadultsbynephelometry AT supapornchaihirunkarn referencevaluesofserumantistreptolysinoinadultsbynephelometry AT sumaleepotprasat referencevaluesofserumantistreptolysinoinadultsbynephelometry AT sudaratsarovath referencevaluesofserumantistreptolysinoinadultsbynephelometry AT sasitornbejrachandra referencevaluesofserumantistreptolysinoinadultsbynephelometry |
_version_ |
1721209037292306432 |