Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data

We discuss here various methodologies and an optimal strategy of the temperature and emission measure diagnostics based on <I>Hinode</I> X-Ray Telescope data. As an example of our results we present the determination of the temperature distribution of the X-rays emitting plasma using...

Full description

Bibliographic Details
Main Authors: M. Siarkowski, R. Falewicz, A. Kępa, P. Rudawy
Format: Article
Language:English
Published: Copernicus Publications 2008-10-01
Series:Annales Geophysicae
Online Access:https://www.ann-geophys.net/26/2999/2008/angeo-26-2999-2008.pdf
id doaj-fb321078e5674a3c8f02745e8ea9eb49
record_format Article
spelling doaj-fb321078e5674a3c8f02745e8ea9eb492020-11-24T23:19:40ZengCopernicus PublicationsAnnales Geophysicae0992-76891432-05762008-10-01262999300510.5194/angeo-26-2999-2008Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT dataM. Siarkowski0R. Falewicz1A. Kępa2P. Rudawy3Space Research Centre, Polish Academy of Sciences, 51-622 Wrocław, ul. Kopernika 11, PolandAstronomical Institute, University of Wrocław, 51-622 Wrocław, ul. Kopernika 11, PolandSpace Research Centre, Polish Academy of Sciences, 51-622 Wrocław, ul. Kopernika 11, PolandAstronomical Institute, University of Wrocław, 51-622 Wrocław, ul. Kopernika 11, PolandWe discuss here various methodologies and an optimal strategy of the temperature and emission measure diagnostics based on <I>Hinode</I> X-Ray Telescope data. As an example of our results we present the determination of the temperature distribution of the X-rays emitting plasma using a filters ratio method and three various methods of the calculation of the differential emission measure (DEM). We have found that all these methods give results similar to the two filters ratio method. Additionally, all methods of the DEM calculation gave similar solutions. We can state that the majority of the pairs of the <I>Hinode</I> filters allows one to derive the temperature and emission measure in the isothermal plasma approximation using standard diagnostics based on the two filters ratio method. In cases of strong flares one can also expect good conformity of the results obtained using a Withbroe – Sylwester, genetic algorithm and least-squares methods of the DEM evaluation.https://www.ann-geophys.net/26/2999/2008/angeo-26-2999-2008.pdf
collection DOAJ
language English
format Article
sources DOAJ
author M. Siarkowski
R. Falewicz
A. Kępa
P. Rudawy
spellingShingle M. Siarkowski
R. Falewicz
A. Kępa
P. Rudawy
Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data
Annales Geophysicae
author_facet M. Siarkowski
R. Falewicz
A. Kępa
P. Rudawy
author_sort M. Siarkowski
title Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data
title_short Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data
title_full Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data
title_fullStr Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data
title_full_unstemmed Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data
title_sort diagnostic of the temperature and differential emission measure (dem) based on <i>hinode</i>/xrt data
publisher Copernicus Publications
series Annales Geophysicae
issn 0992-7689
1432-0576
publishDate 2008-10-01
description We discuss here various methodologies and an optimal strategy of the temperature and emission measure diagnostics based on <I>Hinode</I> X-Ray Telescope data. As an example of our results we present the determination of the temperature distribution of the X-rays emitting plasma using a filters ratio method and three various methods of the calculation of the differential emission measure (DEM). We have found that all these methods give results similar to the two filters ratio method. Additionally, all methods of the DEM calculation gave similar solutions. We can state that the majority of the pairs of the <I>Hinode</I> filters allows one to derive the temperature and emission measure in the isothermal plasma approximation using standard diagnostics based on the two filters ratio method. In cases of strong flares one can also expect good conformity of the results obtained using a Withbroe – Sylwester, genetic algorithm and least-squares methods of the DEM evaluation.
url https://www.ann-geophys.net/26/2999/2008/angeo-26-2999-2008.pdf
work_keys_str_mv AT msiarkowski diagnosticofthetemperatureanddifferentialemissionmeasuredembasedonihinodeixrtdata
AT rfalewicz diagnosticofthetemperatureanddifferentialemissionmeasuredembasedonihinodeixrtdata
AT akepa diagnosticofthetemperatureanddifferentialemissionmeasuredembasedonihinodeixrtdata
AT prudawy diagnosticofthetemperatureanddifferentialemissionmeasuredembasedonihinodeixrtdata
_version_ 1725577628002287616