Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data
We discuss here various methodologies and an optimal strategy of the temperature and emission measure diagnostics based on <I>Hinode</I> X-Ray Telescope data. As an example of our results we present the determination of the temperature distribution of the X-rays emitting plasma using...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Copernicus Publications
2008-10-01
|
Series: | Annales Geophysicae |
Online Access: | https://www.ann-geophys.net/26/2999/2008/angeo-26-2999-2008.pdf |
id |
doaj-fb321078e5674a3c8f02745e8ea9eb49 |
---|---|
record_format |
Article |
spelling |
doaj-fb321078e5674a3c8f02745e8ea9eb492020-11-24T23:19:40ZengCopernicus PublicationsAnnales Geophysicae0992-76891432-05762008-10-01262999300510.5194/angeo-26-2999-2008Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT dataM. Siarkowski0R. Falewicz1A. Kępa2P. Rudawy3Space Research Centre, Polish Academy of Sciences, 51-622 Wrocław, ul. Kopernika 11, PolandAstronomical Institute, University of Wrocław, 51-622 Wrocław, ul. Kopernika 11, PolandSpace Research Centre, Polish Academy of Sciences, 51-622 Wrocław, ul. Kopernika 11, PolandAstronomical Institute, University of Wrocław, 51-622 Wrocław, ul. Kopernika 11, PolandWe discuss here various methodologies and an optimal strategy of the temperature and emission measure diagnostics based on <I>Hinode</I> X-Ray Telescope data. As an example of our results we present the determination of the temperature distribution of the X-rays emitting plasma using a filters ratio method and three various methods of the calculation of the differential emission measure (DEM). We have found that all these methods give results similar to the two filters ratio method. Additionally, all methods of the DEM calculation gave similar solutions. We can state that the majority of the pairs of the <I>Hinode</I> filters allows one to derive the temperature and emission measure in the isothermal plasma approximation using standard diagnostics based on the two filters ratio method. In cases of strong flares one can also expect good conformity of the results obtained using a Withbroe – Sylwester, genetic algorithm and least-squares methods of the DEM evaluation.https://www.ann-geophys.net/26/2999/2008/angeo-26-2999-2008.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
M. Siarkowski R. Falewicz A. Kępa P. Rudawy |
spellingShingle |
M. Siarkowski R. Falewicz A. Kępa P. Rudawy Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data Annales Geophysicae |
author_facet |
M. Siarkowski R. Falewicz A. Kępa P. Rudawy |
author_sort |
M. Siarkowski |
title |
Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data |
title_short |
Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data |
title_full |
Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data |
title_fullStr |
Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data |
title_full_unstemmed |
Diagnostic of the temperature and differential emission measure (DEM) based on <I>Hinode</I>/XRT data |
title_sort |
diagnostic of the temperature and differential emission measure (dem) based on <i>hinode</i>/xrt data |
publisher |
Copernicus Publications |
series |
Annales Geophysicae |
issn |
0992-7689 1432-0576 |
publishDate |
2008-10-01 |
description |
We discuss here various methodologies and an optimal strategy of the
temperature and emission measure diagnostics based on <I>Hinode</I>
X-Ray Telescope data. As an example of our results we present
the determination of the temperature distribution of the X-rays emitting
plasma using a filters ratio method and three various methods of the
calculation of the differential emission measure (DEM). We have
found that all these methods give results similar to the two filters
ratio method. Additionally, all methods of the DEM calculation gave
similar solutions. We can state that the majority of the pairs of
the <I>Hinode</I> filters allows one to derive the temperature and
emission measure in the isothermal plasma approximation using
standard diagnostics based on the two filters ratio method. In cases of
strong flares one can also expect good conformity of the results
obtained using a Withbroe – Sylwester, genetic algorithm and
least-squares methods of the DEM evaluation. |
url |
https://www.ann-geophys.net/26/2999/2008/angeo-26-2999-2008.pdf |
work_keys_str_mv |
AT msiarkowski diagnosticofthetemperatureanddifferentialemissionmeasuredembasedonihinodeixrtdata AT rfalewicz diagnosticofthetemperatureanddifferentialemissionmeasuredembasedonihinodeixrtdata AT akepa diagnosticofthetemperatureanddifferentialemissionmeasuredembasedonihinodeixrtdata AT prudawy diagnosticofthetemperatureanddifferentialemissionmeasuredembasedonihinodeixrtdata |
_version_ |
1725577628002287616 |