Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster

Purpose. To compare anterior chamber depth (ACD), representing the distance between the anterior corneal surface and anterior lens surface measurements between the Galilei Dual Scheimpflug Analyzer and the IOLMaster. Methods. A retrospective review of 65 individual patient eyes with normal anterior...

Full description

Bibliographic Details
Main Authors: Roma P. Patel, Rahul T. Pandit
Format: Article
Language:English
Published: Hindawi Limited 2012-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2012/430249
id doaj-fac9743d40cb42fe9beb37c80b4f5632
record_format Article
spelling doaj-fac9743d40cb42fe9beb37c80b4f56322020-11-24T21:54:22ZengHindawi LimitedJournal of Ophthalmology2090-004X2090-00582012-01-01201210.1155/2012/430249430249Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMasterRoma P. Patel0Rahul T. Pandit1Methodist Eye Associates, The Methodist Hospital, Houston, TX 77030, USAMethodist Eye Associates, The Methodist Hospital, Houston, TX 77030, USAPurpose. To compare anterior chamber depth (ACD), representing the distance between the anterior corneal surface and anterior lens surface measurements between the Galilei Dual Scheimpflug Analyzer and the IOLMaster. Methods. A retrospective review of 65 individual patient eyes with normal anterior segments, and no prior ocular surgery was performed. Patients underwent ACD measurements with both devices during the same session by a trained examiner. Interdevice agreement was evaluated using paired two-tailed t-tests, Pearson correlation coefficient, and Bland-Altman analysis. Results. The mean ± standard deviation (SD) ACD for the Galilei and IOLMaster was 3.37 ± 0.36 mm (range from 2.62 to 4.13) and 3.25 ± 0.38 mm (range from 2.34 to 3.92), respectively (Pearson correlation coefficient = 0.96). ACD mean difference was 0.12 mm (P < 0.0001); 95% limits of agreement was from −0.09 to 0.34. The Galilei measured slightly longer ACD values than the IOLMaster. There was no relationship between axial length and interdevice difference. Conclusion. ACD measurements correlate well between the Galilei and IOLMaster, with Galilei values on average 0.12 mm longer than the IOLMaster.http://dx.doi.org/10.1155/2012/430249
collection DOAJ
language English
format Article
sources DOAJ
author Roma P. Patel
Rahul T. Pandit
spellingShingle Roma P. Patel
Rahul T. Pandit
Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster
Journal of Ophthalmology
author_facet Roma P. Patel
Rahul T. Pandit
author_sort Roma P. Patel
title Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster
title_short Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster
title_full Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster
title_fullStr Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster
title_full_unstemmed Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster
title_sort comparison of anterior chamber depth measurements from the galilei dual scheimpflug analyzer with iolmaster
publisher Hindawi Limited
series Journal of Ophthalmology
issn 2090-004X
2090-0058
publishDate 2012-01-01
description Purpose. To compare anterior chamber depth (ACD), representing the distance between the anterior corneal surface and anterior lens surface measurements between the Galilei Dual Scheimpflug Analyzer and the IOLMaster. Methods. A retrospective review of 65 individual patient eyes with normal anterior segments, and no prior ocular surgery was performed. Patients underwent ACD measurements with both devices during the same session by a trained examiner. Interdevice agreement was evaluated using paired two-tailed t-tests, Pearson correlation coefficient, and Bland-Altman analysis. Results. The mean ± standard deviation (SD) ACD for the Galilei and IOLMaster was 3.37 ± 0.36 mm (range from 2.62 to 4.13) and 3.25 ± 0.38 mm (range from 2.34 to 3.92), respectively (Pearson correlation coefficient = 0.96). ACD mean difference was 0.12 mm (P < 0.0001); 95% limits of agreement was from −0.09 to 0.34. The Galilei measured slightly longer ACD values than the IOLMaster. There was no relationship between axial length and interdevice difference. Conclusion. ACD measurements correlate well between the Galilei and IOLMaster, with Galilei values on average 0.12 mm longer than the IOLMaster.
url http://dx.doi.org/10.1155/2012/430249
work_keys_str_mv AT romappatel comparisonofanteriorchamberdepthmeasurementsfromthegalileidualscheimpfluganalyzerwithiolmaster
AT rahultpandit comparisonofanteriorchamberdepthmeasurementsfromthegalileidualscheimpfluganalyzerwithiolmaster
_version_ 1725867324659990528